Electrochemical detection of glucose in sweat using a paper-based origami biosensor based on PEDOT:PSS/Ti3C2/MWCNT composite

被引:3
|
作者
Moradi, Sara [1 ]
Hosseini, Morteza [1 ,2 ]
Firoozbakhtian, Ali [1 ]
Tashnizi, Mohammad Barshan [3 ]
Ganjali, Mohammad Reza [4 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Life Sci Engn, Nanobiosensors Lab, Tehran 1439817435, Iran
[2] Univ Tehran Med Sci, Med Biomat Res Ctr, Tehran, Iran
[3] Univ Tehran, Fac New Sci & Technol, Dept Life Sci Engn, Tehran, Iran
[4] Univ Tehran, Coll Sci, Ctr Excellence Electrochem, Sch Chem, Tehran 1439817435, Iran
关键词
Origami; Paper-based-Biosensor; Glucose; Electrochemistry; Sweat; CARBON NANOTUBES; IMMOBILIZATION; ELECTRODE; DEVICE; ENZYME; SENSOR;
D O I
10.1016/j.jelechem.2024.118675
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Origami glucose biosensors utilize folding techniques to create compact, cost-effective devices for monitoring glucose levels and offer great potential in healthcare and diagnostics applications. The origami design of the biosensor allows for easy handling and transport, making it ideal for point-of-care testing in resource-limited areas, especially for individuals with diabetes to monitor glucose levels. This study introduced a novel paper-based origami glucose biosensor with graphite pencil electrodes which directly drawn onto the paper surface. A simple method used to draw two circular areas for effective immobilization of the mediator and glucose oxidase enzyme. A novel mediator composed of MWCNT and Ti3C2 dissolved in PEDOT:PSS ink was introduced to the mediator zone to enhance the paper surface's conductivity, thereby boosting the electron transfer rate from the enzyme region to the electrodes. The mediator ink was produced by using a straightforward one-step process, eliminating the necessity for specialized equipment and intricate synthesis techniques. Also, the mediator composite lowered the applied potential for glucose oxidation reaction according to the high surface area, unique electronic properties, and excellent catalytic activity of the composite. The lower potentials for glucose oxidation are required to avoid the electrochemical oxidation of interfering substances, to reach a high accuracy in the detection of the analyte. With a detection limit of 0.007 mM and linear range of 0.01 mM to 0.4 mM, it covers a wide range of glucose concentrations found in sweat.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Cus@rGO Grafted PEDOT:PSS Paper-Based Electrochemical Biosensor for Sensitive Detection of Fenitrothion
    Bohra, Poornima
    Priya, Divya
    Sweety, Devendra
    Hudda, Divya
    Kumar, Devendra
    APPLIED ORGANOMETALLIC CHEMISTRY, 2025, 39 (02)
  • [2] A Facile Approach for the Electrochemical Sensing of Dopamine using Paper-Based PEDOT:PSS/RGO Graphene Biosensor
    Settu, Kalpana
    Huang, Yu-Ming
    Zhou, Sheng-Xuan
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2020, 9 (12)
  • [3] CuO@PEDOT:PSS-grafted paper-based electrochemical biosensor for paraoxon-ethyl detection
    Paneru, Saroj
    Sweety
    Kumar, Devendra
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2023, 53 (11) : 2229 - 2238
  • [4] CuO@PEDOT:PSS-grafted paper-based electrochemical biosensor for paraoxon-ethyl detection
    Saroj Paneru
    Devendra Sweety
    Journal of Applied Electrochemistry, 2023, 53 : 2229 - 2238
  • [5] Microfluidic paper-based wearable electrochemical biosensor for reliable cortisol detection in sweat
    Fiore, Luca
    Mazzaracchio, Vincenzo
    Serani, Aristi
    Fabiani, Giorgia
    Fabiani, Laura
    Volpe, Giulia
    Moscone, Danila
    Bianco, Giulio Maria
    Occhiuzzi, Cecilia
    Marrocco, Gaetano
    Arduini, Fabiana
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 379
  • [6] A wearable origami-like paper-based electrochemical biosensor for sulfur mustard detection
    Colozza, Noemi
    Kehe, Kai
    Dionisi, Giulio
    Popp, Tanja
    Tsoutsoulopoulos, Amelie
    Steinritz, Dirk
    Moscone, Danila
    Arduini, Fabiana
    BIOSENSORS & BIOELECTRONICS, 2019, 129 : 15 - 23
  • [7] Ti3C2/Ni/Sm-based electrochemical glucose sensor for sweat analysis using bipolar electrochemistry
    Damirchi, Zahra
    Firoozbakhtian, Ali
    Hosseini, Morteza
    Ganjali, Mohammad Reza
    MICROCHIMICA ACTA, 2024, 191 (03)
  • [8] Ti3C2/Ni/Sm-based electrochemical glucose sensor for sweat analysis using bipolar electrochemistry
    Zahra Damirchi
    Ali Firoozbakhtian
    Morteza Hosseini
    Mohammad Reza Ganjali
    Microchimica Acta, 2024, 191
  • [9] CuS modified PEDOT:PSS grafted paper-based electrochemical immunosensor for EpCAM biomarker detection
    Sweety
    Paneru, Saroj
    Kumar, Devendra
    MATERIALS CHEMISTRY AND PHYSICS, 2024, 313
  • [10] Electrochemical paper based cancer biosensor using iron oxide nanoparticles decorated PEDOT:PSS
    Kumar, Saurabh
    Umar, Mohammad
    Saifi, Anas
    Kumar, Suveen
    Augustine, Shine
    Srivastava, Saurabh
    Malhotra, Bansi D.
    ANALYTICA CHIMICA ACTA, 2019, 1056 : 135 - 145