Topology and DC Fault Ride-through Strategy of Embedded Modular Multilevel Converter with High-/low-voltage Valve Connection

被引:0
|
作者
Zhang, Ziru [1 ]
Fu, Fenghao [2 ]
Zhao, Xibei [1 ]
Jia, Xiufang [1 ]
机构
[1] State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources (North China Electric Power University), Beijing,102206, China
[2] High Voltage Branch of State Grid Tianjin Electric Power Company, Tianjin,300232, China
关键词
D O I
10.7500/AEPS20231116001
中图分类号
学科分类号
摘要
引用
收藏
页码:154 / 164
相关论文
共 50 条
  • [21] Modular Multilevel Converter Based Topology for High-Speed, Low-Voltage Electric Drives
    Tarisciotti, Luca
    Costabeber, Alessandro
    Tardelli, Francesco
    Cardenas, Roberto
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (05) : 5202 - 5211
  • [22] Active Fault Current Limitation for Low-Voltage Ride-Through of Networked Microgrids
    Liu, Xubin
    Chen, Xinyu
    Shahidehpour, Mohammad
    Li, Canbing
    Wu, Qiuwei
    Wu, Yuhang
    Wen, Jinyu
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (02) : 980 - 992
  • [23] Zero DC voltage ride through of a hybrid modular multilevel converter in HVDC systems
    Lu, Maozeng
    Hu, Jiabing
    Lin, Lei
    Xu, Kecheng
    [J]. IET RENEWABLE POWER GENERATION, 2017, 11 (01) : 35 - 43
  • [24] Voltage Ride through Control Strategy of Modular Multilevel Converter under Unbalanced Voltage Sag
    Hakimi, Seyed Mehdi
    Hajizadeh, Amin
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (03):
  • [25] Low-voltage ride-through control strategy for flywheel energy storage system
    Zheng, Xuechen
    Wu, Zhenkui
    Song, Gengling
    Zhang, Jihong
    Yang, Peihong
    Zhang, Zilei
    Lu, Xingsheng
    [J]. ENERGY SCIENCE & ENGINEERING, 2024, 12 (04) : 1486 - 1502
  • [26] Overall coordinated low voltage ride-through control strategy for grid connection of a photovoltaic DC booster station
    Niu H.
    Jia K.
    Liu X.
    Li J.
    Chen J.
    Bi T.
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (08): : 1 - 12
  • [27] Low-voltage ride-through of a full converter wind turbine with permanent magnet generator
    Conroy, J. F.
    Watson, R.
    [J]. IET RENEWABLE POWER GENERATION, 2007, 1 (03) : 182 - 189
  • [28] DC fault ride-through capability and STATCOM operation of a HVDC hybrid voltage source converter
    Feldman, Ralph
    Farr, Ewan
    Watson, Alan J.
    Clare, Jon C.
    Wheeler, Patrick W.
    Trainer, David R.
    Crookes, R. Will
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (01) : 114 - 120
  • [29] Improved hybrid modular multilevel converters with dc short-circuit fault ride-through capacity
    Lei, Yuhang
    Si, Gangquan
    Zhu, Jianwei
    Zhang, Yanbing
    [J]. JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1194 - 1198
  • [30] Power-Angle Synchronization for Grid-Connected Converter With Fault Ride-Through Capability for Low-Voltage Grids
    Mukherjee, Subhajyoti
    Chowdhury, Vikram Roy
    Shamsi, Pourya
    Ferdowsi, Mehdi
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (03) : 970 - 979