Topology optimization of scanning mirror of UV to near-infrared hyperspectral detector

被引:0
|
作者
机构
[1] Cao, Diansheng
来源
| 1600年 / Chinese Society of Astronautics卷 / 43期
关键词
Shape optimization - Deformation - Infrared devices - Scanning - Topology;
D O I
暂无
中图分类号
学科分类号
摘要
In order to study the lightweight issues of the scanning mirror of the UV to near -infrared hyperspectral detector while the mirror was rotating, the topology optimization method based on the constrain of dynamic deformation was proposed. Simplifications were carried out to reduce the calculation complexity of the design constrains. With the topology optimization method, an optimal lightweight form of the scanning mirror was obtained on the condition of rotation. The result shows that the lightweight ratio of the optimized scanning mirror is 47.3%. For the optimized structure, the PV value is 19.36 nm and the RMS value is 5.65 nm, which are improved by 18.45% and 17.41% compared with the initial scanning mirror, respectively. At the same time, the first order frequency of the scanning mirror increases by 113.8 Hz. The results illustrate that the topology optimization method with the constrain of the dynamic deformation of the scanning mirror is reasonable and effective. ©, 2014, Chinese Society of Astronautics. All right reserved.
引用
收藏
相关论文
共 50 条
  • [41] Detection of bruises on apples using near-infrared hyperspectral imaging
    Lu, R
    TRANSACTIONS OF THE ASAE, 2003, 46 (02): : 523 - 530
  • [42] FEASIBILITY OF INTRACRANIAL NEAR-INFRARED OPTICAL-SCANNING
    GRATTON, G
    MAIER, JS
    FABIANI, M
    MANTULIN, WW
    GRATTON, E
    PSYCHOPHYSIOLOGY, 1994, 31 (02) : 211 - 215
  • [43] Laser Safety in Design of Near-Infrared Scanning LIDARs
    Zhu, X.
    Elgin, D.
    LASER RADAR TECHNOLOGY AND APPLICATIONS XX; AND ATMOSPHERIC PROPAGATION XII, 2015, 9465
  • [44] NEAR-INFRARED RAMAN-SPECTROSCOPY WITH A SCANNING SPECTROMETER
    ENGERT, C
    MICHELIS, T
    KIEFER, W
    APPLIED SPECTROSCOPY, 1991, 45 (08) : 1333 - 1339
  • [45] InGaAs trap detector used as a near-infrared transfer standard for detector calibrations
    Wang, J
    Li, S
    Zhang, L
    Chen, F
    Zheng, XB
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150
  • [46] Measurement optimization for near-infrared optical tomography
    Kumar, YP
    Dehghani, H
    Pogue, BW
    Paulsen, KD
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VI, 2005, 5693 : 64 - 73
  • [47] Optimization and Analysis of near-infrared InGaAs detectors
    Wang, Qingsong
    Chen, Jun
    Lv, Jiabing
    Wang, Mingxiang
    Li, Xue
    Tang, Hengjing
    INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
  • [48] Near-Infrared Imaging Using a High-Speed Monitoring Near Infrared Hyperspectral Camera (Compovision)
    Ishikawa, Daitaro
    Motomura, Asako
    Igarashi, Yoko
    Ozaki, Yukihiro
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (04) : 865 - 869
  • [49] Design for source-and-detector configuration of a ring-scanning-based near-infrared optical imaging system
    Yu, Jhao-Ming
    Pan, Min-Cheng
    Pan, Min-Chun
    OPTICAL ENGINEERING, 2014, 53 (01)
  • [50] Development of a new readout system for the near-infrared detector of HONIR
    Ui, Takahiro
    Sako, Shigeyuki
    Yamashita, Takuya
    Akitaya, Hiroshi
    Kawabata, Koji S.
    Nakaya, Hidehiko
    Moritani, Yuki
    Itoh, Ryosuke
    Takaki, Katsutoshi
    Urano, Takeshi
    Ueno, Issei
    Ohsugi, Takashi
    Yoshida, Michitoshi
    Nakao, Hikaru
    Hashiba, Yasuhito
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY V, 2014, 9147