Optimal power flow and grid frequency control of conventional and renewable energy source using evolutionary algorithm based FOPID controller

被引:0
|
作者
Upadhaya, Debodyuti [1 ]
Biswas, Soumen [2 ]
Dutta, Susanta [2 ]
Bhattacharya, Anagha [3 ]
机构
[1] JIS Coll Engn, Dept Elect Engn, Kalyani, Nadia, India
[2] Dr B C Roy Engn Coll, Dept Elect Engn, Durgapur 713206, India
[3] NIT Mizoram, Dept Elect Engn, Aizawl, Mizoram, India
关键词
FOPID controller; Gazelle Optimization Algorithm (GZA); Load Frequency Control (LFC); Optimal Power Flow (OPF); Renewable energy (Wind & solar & EV); EMISSION; SYSTEM; COST;
D O I
10.1016/j.ref.2024.100676
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The primary objective of optimal power flow (OPF) in power systems is to minimize fuel expenses while simultaneously addressing several critical factors,including reducing transmission losses, minimizing voltage variations, and enhancing overall system stability. As the energy landscape evolves, the integration of renewable energy sources (RES) into the power grid has become increasingly important. In this research article, a study of Automatic Generation Control including RES to achieve cost optimization highlighting the advantages of GZA algorithm through a comprehensive study with other two evolutionary algorithm has been done. The research focuses on a three-area system integrating renewable energy sources - specifically solar, wind, and electric vehicles (EVs) - within a deregulated environment. While these sources can significantly reduce fuel costs associated with thermal power plants, they also introduce new challenges. Specifically, the variability and unpredictability of renewable energy can lead to increased frequency deviations due to changes in load inertia. This frequency deviation can disrupt the synchronization of the power system, potentially compromising stability and reliability. Detail study has been done in the simulation results for frequency deviation to achieve LFC, emphasizing performance metrics like overshoot, undershoot, and steady-state stability. Both traditional PID and FOPID controllers were evaluated for their effectiveness in managing frequency deviations.LFC ensures that the frequency of the power system remains within acceptable limits, particularly in a multi-area system where different regions may experience varying loads and generation capabilities. Effective frequency control is essential for maintaining the balance between generation and consumption, which is vital for the smooth operation of the grid. This innovative approach aims to enhance frequency regulation by effectively managing the dynamics introduced by the incorporation of renewable energy sources alongside traditional thermal power generation. The findings aim to demonstrate the effectiveness of the evolutionary algorithm GZA in enhancing the overall performance of multi-area power systems with diverse generation sources. By providing insights into the benefits of advanced control strategies, this study has been introduced a novel approach to simultaneously minimize costs and manage frequency deviations, marking a significant advancement in the field.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Optimal Control for a Renewable-energy-based Micro-grid
    Ornelas-Tellez, Fernando
    2014 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2014,
  • [42] Optimal design of grid-connected hybrid renewable energy systems using multi-objective evolutionary algorithm
    Shi, Z. S.
    Wang, R.
    Zhang, X. Y.
    Zhang, Y.
    Zhang, T.
    SCIENTIA IRANICA, 2017, 24 (06) : 3148 - 3156
  • [43] Comparison of automatic load frequency control in two area power systems using pso algorithm based pid controller and conventional pid controller
    Singh, Ranjit
    Ramesh, L.
    INTERNATIONAL CONFERENCE ON APPLIED PHYSICS, POWER AND MATERIAL SCIENCE, 2019, 1172
  • [44] Control of Single Phase Power Inverter using Model Predictive Controller for Grid Integrated Renewable Energy Systems
    Chatterjee, A.
    Mohanty, K. B.
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 1678 - 1681
  • [45] Probabilistic optimal power flow in power systems with Renewable energy integration using Enhanced walrus optimization algorithm
    Hasanien, Hany M.
    Alsaleh, Ibrahim
    Ullah, Zia
    Alassaf, Abdullah
    AIN SHAMS ENGINEERING JOURNAL, 2024, 15 (03)
  • [46] Flow direction algorithm-based optimal power flow analysis in the presence of stochastic renewable energy sources
    Maheshwari, Ankur
    Sood, Yog Raj
    Jaiswal, Supriya
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 216
  • [47] Optimal Control Strategy of a Unified Power Flow Controller Incorporated with an Active Power Source
    Wang Qi
    Yi Jun
    Liu Liping
    2015 IEEE INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2015, : 264 - 269
  • [48] Design of cascade P-P-FOPID controller based on marine predators algorithm for load frequency control of electric power systems
    Hussain, Jahanzeab
    Zou, Runmin
    Akhtar, Samina
    Abouda, Khalid A.
    ELECTRICAL ENGINEERING, 2025, 107 (01) : 809 - 827
  • [49] NOVEL COOPERATIVE FPA-ATS ALGORITHM AND ITS APPLICATION TO OPTIMAL FOPID CONTROLLER DESIGN FOR LOAD FREQUENCY CONTROL
    Niyomsat, Thitipong
    Puangdownreong, Deacha
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2020, 16 (06): : 1877 - 1894
  • [50] Distributed optimal power flow for smart grid transmission system with renewable energy sources
    Lin, Shin-Yeu
    Chen, Jyun-Fu
    ENERGY, 2013, 56 : 184 - 192