Performance evaluation of the combined helium Brayton cycle and organic Rankine cycles for solar power tower application-A comparative study

被引:0
|
作者
Khan, Yunis [1 ]
Singh, Deepak [2 ]
Kumar, Saket [3 ]
Mishra, Subhash [4 ]
Anjum, Aftab [5 ]
Asdaque, P. M. G. Bashir [6 ]
机构
[1] Indian Inst Technol ISM, Dept Mech Engn, Dhanbad 826004, Jharkhand, India
[2] Sardar Patel Coll Engn, Dept Mech Engn, Mumbai 400058, Maharashtra, India
[3] Dronacharya Grp Inst, Dept Mech Engn, Greater Noida, Uttar Pradesh, India
[4] IMS Engn Coll, Dept Mech Engn, Ghaziabad 201015, Uttar Pradesh, India
[5] Delhi Technol Univ, Dept Mech Engn, Bawana Rd, Delhi 110042, India
[6] Dayananda Sagar Univ, Dept Mech Engn, Bangalore, India
关键词
ENERGY;
D O I
10.1063/5.0239706
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar energy is the prime renewable energy source to provide the carbon-free power. However, various irreversibilities are associated with the solar power tower (SPT) system, and they cannot be avoided. Therefore, to enhance the performance of the solar power plant, in this work, four configurations of the combined cycles have been considered for harvesting the solar heat from the SPT system, and the performance of all the considered power systems was compared with the SPT-based conventional helium Brayton cycle (HBC) system. These four proposed combined cycles used HBC as the topping cycle and basic organic Rankine cycle (ORC), recuperative ORC, regenerative ORC, and regenerative-recuperative ORC (RRORC) as bottoming cycles separately. Energy and exergy analyses of the proposed power generation systems were performed based on numerical technique using the computational software engineering equation solver. It was concluded that the SPT-HBC-RRORC system was considered the best-performing power generation system among the other considered power systems. The SPT-HBC-RRORC system achieved energy efficiency, exergy efficiency, and net work output, respectively, as 7.69%, 8.09%, and 21.69% higher than that of the conventional system (SPT-HBC). However, the SPT-HBC-RRORC system achieved 5.44%, 5.08%, and 18.51% higher energy efficiency, exergy efficiency, and net work output, respectively, than that of the SPT-HBC-basic ORC. Therefore, the SPT-HBC-RRORC system is far better than the conventional SPT-HBC system. The parametric analysis indicates that the parameters related to the solar subsection significantly influence the power generation unit's performance.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Performance evaluation of a combined cycle power plant integrated with organic Rankine cycle and absorption refrigeration system
    Njoku, I. H.
    Oko, C. O. C.
    Ofodu, J. C.
    COGENT ENGINEERING, 2018, 5 (01):
  • [22] Performance of S-CO2 Brayton Cycle and Organic Rankine Cycle (ORC) Combined System Considering the Diurnal Distribution of Solar Radiation
    Wei Gao
    Mingyu Yao
    Yong Chen
    Hongzhi Li
    Yifan Zhang
    Lei Zhang
    Journal of Thermal Science, 2019, 28 : 463 - 471
  • [23] Performance comparison of different supercritical carbon dioxide Brayton cycles integrated with a solar power tower
    Al-Sulaiman, Fahad A.
    Atif, Maimoon
    ENERGY, 2015, 82 : 61 - 71
  • [24] Performance of S-CO2 Brayton Cycle and Organic Rankine Cycle(ORC) Combined System Considering the Diurnal Distribution of Solar Radiation
    GAO Wei
    YAO Mingyu
    CHEN Yong
    LI Hongzhi
    ZHANG Yifan
    ZHANG Lei
    JournalofThermalScience, 2019, 28 (03) : 463 - 471
  • [25] Performance of S-CO2 Brayton Cycle and Organic Rankine Cycle (ORC) Combined System Considering the Diurnal Distribution of Solar Radiation
    Gao Wei
    Yao Mingyu
    Chen Yong
    Li Hongzhi
    Zhang Yifan
    Zhang Lei
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (03) : 463 - 471
  • [26] Hybridisation of biomass and concentrated solar power systems in transcritical organic Rankine cycles: A micro combined heat and power application
    Morrone, Pietropaolo
    Algieri, Angelo
    Castiglione, Teresa
    ENERGY CONVERSION AND MANAGEMENT, 2019, 180 : 757 - 768
  • [27] Energy-exergy analysis for performance improvement of Brayton-Rankine combined cycle system by utilizing a solar absorption refrigeration cycle (case study: Kahnuj Combined Cycle Power Plant)
    Esfandiari, Moslem
    Pourfayaz, Fathollah
    Kasaeian, Alibakhsh
    Gholami, Ali
    ENERGY SCIENCE & ENGINEERING, 2024, 12 (01) : 201 - 214
  • [28] Techno-economic assessment of a solar-based novel power generation system formed from a helium Brayton cycle and an organic Rankine flash cycle
    Department of Mechanical Engineering, Amity University, Noida, India
    不详
    不详
    Front. Energy Res., 2024,
  • [29] Energy and exergy analysis of a closed Brayton cycle-based combined cycle for solar power tower plants
    Zare, V.
    Hasanzadeh, M.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 128 : 227 - 237
  • [30] Evaluation of performance improvement of the combined biomass gasifier power cycle using low-temperature bottoming cycles: Organic Rankine cycle, Kalina and Goswami
    Hosseinpour, Mohammad
    Ozgoli, Hassan Ali
    Mirzahosseini, Seyed Alireza Hajiseyed
    Hemmasi, Amir Hooman
    Mehdipour, Ramin
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2022, 41 (05)