Efficacy evaluation of bicarbonate formulations dry water fire extinguishing agents

被引:0
|
作者
Wang, Xiang [1 ]
Jiang, Jun-Cheng [1 ,2 ]
Wang, Yong-Qi [1 ]
Chu, Sheng-Li [3 ]
Zhu, Fei-Hao [1 ]
Huang, An-Chi [1 ]
机构
[1] Changzhou Univ, Sch Safety Sci & Engn, 21 Gehu Mid Rd, Changzhou 213164, Jiangsu, Peoples R China
[2] Nanjing Tech Univ, Coll Safety Sci & Engn, 30 South Puzhu Rd, Nanjing 211816, Jiangsu, Peoples R China
[3] China Natl Petr Corp, Safety & Environm Protect Technol Res Inst, Bldg 1,Yard 1,Huangbei St, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Dry water fire extinguishing agent; Magnesium bicarbonate; Calcium bicarbonate; Thermogravimetric analysis; Fire extinguishing efficiency; THERMAL-STABILITY; BIOMASS GEL; MIST; PERFORMANCE;
D O I
10.1016/j.jlp.2024.105444
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The fire situation has gotten worse over the past few years. To put out flames, we desperately need more effective and sustainable fire extinguishing products. The primary goal of this research is to increase the dry water (DW) core-shell structure's stability and water retention-but more significantly, to increase the structure's fire extinguishing effectiveness. The following five materials are introduced in this article: dimethyl silicone oil, lauryl ether phosphate ester (AEO-3P), gelled adhesive, gallium bicarbonate (Ca(HCO3)(2)), and magnesium bicarbonate (Mg(HCO3)(2)). The water content of DW increased to 88%-94% with the addition of gel and dimethyl silicone oil, according to thermogravimetric analysis and moisture retention tests. By altering the characteristics of the liquid-solid interface between the hydrophobic silica and the aqueous solution, lauryl ether phosphate increased the stability of the DW structure. This study also examined and contrasted the effectiveness of five commercial dry powder fire extinguishing agents and DW fire extinguishing agents in terms of fire extinguishing efficiency. The findings indicate that the Mg(HCO3)(2) gel DW extinguishing time in n-heptane fire is the smallest (9 s), while the Ca(HCO3)(2) gel DW extinguishing time in anhydrous ethanol fire is the shortest (9 s). The extinguishing efficiency of the two is boosted by 66% and 55%, respectively, in comparison to commercial dry powder. By developing a new kind of stable, effective, and non-toxic fire extinguishing chemical, this work has benefited the firefighting and rescue sectors.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Sustained effect of dry water in a thermal environment after fire extinguishing: Fuel surface coating methods
    Zhang Tianwei
    Liu Xiangchen
    Wang Guofeng
    Liu Hao
    Xiao Lei
    Ye Qiaohan
    Liang Qiang
    Zhang Cunwei
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [32] Review of fire extinguishing agents and fire suppression strategies for lithium-ion battery fire
    Huang, Jiang
    Jin, Jianquan
    Zhao, Liang
    Liang, Jiaxin
    Chen, Yonggang
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2024, 46 (11): : 2121 - 2132
  • [33] Advanced fire extinguishing agents/media usable in timber industry
    Orlíková, K
    Hrdy, R
    Libor, S
    WOOD & FIRE SAFETY, PT 1 PROCEEDINGS, 2000, : 235 - 242
  • [34] Wood stack fire tests to evaluate the influence of extinguishing medium and driving pressure on fire extinguishing efficacy of forest trees
    Huang, Congbao
    Dai, Zhangyin
    Jiang, Zebiao
    Chen, Youcheng
    Zhong, Manyin
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 49
  • [35] Comparison of carbon dioxide and helium as fire extinguishing agents for spacecraft
    University of Southern California, OHE430, 3650 McClintock Ave., LA, CA 90089
    不详
    J. ASTM Int., 2006, 3
  • [36] Toxicological observations into some modern fire extinguishing agents.
    Joachimoglu, G
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1930, 56 : 785 - 787
  • [37] EXPERIMENTAL EVALUATION THE EFFECTIVENESS OF WATER MIST FIRE EXTINGUISHING SYSTEMS AT OIL AND GAS INDUSTRY
    Nyashina, G. S.
    Medvedev, V. V.
    Shevyrev, S. A.
    Vysokomornaya, O. V.
    THERMOPHYSICAL BASIS OF ENERGY TECHNOLOGIES 2015, 2016, 110
  • [38] HOT AEROSOL FIRE EXTINGUISHING AGENTS AND THE ASSOCIATED TECHNOLOGIES: A REVIEW
    Zhang, Xiaotian
    Ismail, Mohd Halim Shah
    Ahmadun, Fakhrul-Razi B.
    Abdullah, Norhafizah Bt. Hj.
    Hee, Choi
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2015, 32 (03) : 707 - 724
  • [39] Experimental evaluation of the effectiveness of water mist automated fire extinguishing systems for oil transportation
    Glushkov, D. O.
    Nyashina, G. S.
    Strizhak, P. A.
    Volkov, R. S.
    XIX INTERNATIONAL SCIENTIFIC SYMPOSIUM IN HONOR OF ACADEMICIAN M.A. USOV PROBLEMS OF GEOLOGY AND SUBSURFACE DEVELOPMENT, 2015, 27
  • [40] Design for water automatic fire extinguishing system of hydrogenerator
    Tang, Yize
    1998,