The mid-infrared atmospheric transmittance and radiation were calculated with four different HITRAN databases using LBL software. Results show that atmospheric transmittance is increases with the transmission path decreases. Radiation decreases with the transmission path decreases. The transmittance average absolute deviation of HITRAN96, HITRAN2k and HITRAN04 is small in the three downlink propagation. But the transmittance absolute deviation is larger in some bands, such as the maximum absolute deviation of HITRAN2k up to 0.81 in transmission path from 100 to 10 km. The radiation average absolute deviation level of HITRAN96, HITRAN2k and HITRAN04 is 10-6 in the three downlink propagation. The deviation caused by old versions of the database should be considered for calculating infrared atmospheric transmittance and radiation. The difference caused by different versions of the database should be considered.
引用
收藏
相关论文
共 50 条
  • [21] Recording of mid-infrared radiation in photochromic polymers
    1600, American Inst of Physics, Woodbury, NY, USA (74):
  • [22] Recording of mid-infrared radiation in photochromic polymers
    Weiss, V.
    Friesem, A.A.
    Krongauz, V.A.
    Journal of Applied Physics, 1993, 74 (06): : 4248 - 4250
  • [23] Bracket debonding by mid-infrared laser radiation
    Jelinkova, H.
    Sulc, J.
    Dostalova, T.
    Koranda, P.
    Nemec, M.
    Hofmanova, P.
    LASER PHYSICS LETTERS, 2009, 6 (03) : 222 - 228
  • [24] Study on Atmospheric Transmission Characteristics of the Mid-Infrared Laser
    Zhang, Yizhuo
    Hu, Wenhua
    Wang, Yanxin
    STRUCTURAL ENGINEERING, VIBRATION AND AEROSPACE ENGINEERING, 2014, 482 : 273 - 276
  • [25] Mid-infrared atmospheric transmittance measurements by using the second and third harmonics of tunable TEA-CO2 laser
    Harasaki, A
    Sakuma, J
    Itoh, T
    Chonan, T
    Fukuyama, Y
    Horie, R
    Sugii, M
    PROPAGATION AND IMAGING THROUGH THE ATMOSPHERE, 1997, 3125 : 410 - 418
  • [26] Calculation of silicon antireflective microstructures for mid-infrared applications
    Song, Y. M.
    Chang, K. S.
    2014 14TH INTERNATIONAL CONFERENCE ON NUMERICAL SIMULATION OF OPTOELECTRONIC DEVICES (NUSOD 2014), 2014, : 33 - +
  • [27] Focal Lengths Calculation of Metalens at Mid-infrared Wavelength
    Zhang, Xiaodong
    Wu, Xinpeng
    Zhu, Xue
    Ye, Guoyong
    Jiang, Liying
    RUSSIAN PHYSICS JOURNAL, 2024, 67 (05) : 667 - 674
  • [28] ATMOSPHERIC TRANSMITTANCE IN INFRARED
    MCCLATCH.RA
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1973, 63 (04) : 485 - 485
  • [29] Ultra-smooth processing of lithium niobate for outstanding mid-infrared transmittance
    Tian, Ke-Shuai
    Li, Hong-Yu
    Wang, Zhen
    Zheng, Jia-Xin
    Zhang, Xin
    Wang, Lei
    Liu, Xue-Qing
    OPTICS LETTERS, 2024, 49 (18) : 5067 - 5070
  • [30] Infrared radiation measurement based on proportional corrected atmospheric transmittance
    Yang, Ci-Yin
    Zhang, Jian-Ping
    Cao, Li-Hua
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2012, 20 (07): : 1626 - 1635