In vivo measurements of moment arm lengths of three elbow flexors at rest and during isometric contractions

被引:0
|
作者
机构
[1] Akagi, Ryota
[2] 2,Iwanuma, Soichiro
[3] Hashizume, Satoru
[4] Kanehisa, Hiroaki
[5] Yanai, Toshimasa
[6] Kawakami, Yasuo
来源
Akagi, R. | 1600年 / Human Kinetics Publishers Inc.卷 / 28期
关键词
The purpose of this study was to determine in vivo moment arm lengths (MAs) of three elbow flexors at rest and during low- and relatively high-intensity contractions; and to examine the contraction intensity dependence of MAs at different joint positions. At 50°; 80° and 110° of elbow flexion; MAs of the biceps brachii; brachialis and brachioradialis were measured in 10 young men using sagittal images of the right arm obtained by magnetic resonance imaging; at rest and during 20% and 60% of isometric maximal voluntary elbow flexion. In most conditions; MAs increased with isometric contractions; which is presumably due to the contraction-induced thickening of the muscles. This phenomenon was especially evident in the flexed elbow positions. The influence of the contraction intensities on the increases in MAs varied across the muscles. These results suggest that in vivo measurements of each elbow flexor MA during contractions are essential to properly examine the effects on the interrelationships between elbow flexion torque and individual muscle forces. © 2012 Human Kinetics; Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [21] Circadian rhythm in the torque developed by elbow flexors during isometric contraction, effect of sampling schedules
    Gauthier, A
    Davenne, D
    Gentil, C
    VanHoecke, J
    CHRONOBIOLOGY INTERNATIONAL, 1997, 14 (03) : 287 - 294
  • [22] EMG POWER SPECTRA OF ELBOW EXTENSORS DURING RAMP AND STEP ISOMETRIC CONTRACTIONS
    BILODEAU, M
    ARSENAULT, AB
    GRAVEL, D
    BOURBONNAIS, D
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1991, 63 (01): : 24 - 28
  • [23] Acute Testosterone Deficiency Affects Electrical Properties Of Elbow Flexors And Extensors During Voluntary Contractions
    Quinzi, Federico
    Bazzucchi, Ilenia
    Conti, Alessandra
    Felici, Francesco
    Romanelli, Francesco
    Sgro', Paolo
    Di Luigi, Luigi
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 801 - 801
  • [24] THE EFFECT OF SEAT HEIGHT ON MUSCLE LENGTHS, VELOCITIES AND MOMENT ARM LENGTHS DURING CYCLING
    RUGG, SG
    GREGOR, RJ
    JOURNAL OF BIOMECHANICS, 1987, 20 (09) : 899 - 899
  • [25] Residual force enhancement during voluntary contractions of knee extensors and flexors at short and long muscle lengths
    Shim, Jaeho
    Garner, Brian
    JOURNAL OF BIOMECHANICS, 2012, 45 (06) : 913 - 918
  • [26] Lower excitability of the corticospinal tract to transcranial magnetic stimulation during lengthening contractions in human elbow flexors
    Sekiguchi, H
    Kimura, T
    Yamanaka, K
    Nakazawa, K
    NEUROSCIENCE LETTERS, 2001, 312 (02) : 83 - 86
  • [27] DIFFERENCES IN ACTIVATION PATTERNS IN ELBOW FLEXOR MUSCLES DURING ISOMETRIC, CONCENTRIC AND ECCENTRIC CONTRACTIONS
    NAKAZAWA, K
    KAWAKAMI, Y
    FUKUNAGA, T
    YANO, H
    MIYASHITA, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 66 (03): : 214 - 220
  • [28] Electromyographic measures of muscle activation and changes in muscle architecture of human elbow flexors during fatiguing contractions
    Rudroff, Thorsten
    Staudenmann, Didier
    Enoka, Roger M.
    JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (06) : 1720 - 1726
  • [29] POWER SPECTRUM OF ELECTROMYOGRAPHY IN ARM AND LEG MUSCLES DURING ISOMETRIC CONTRACTIONS AND FATIGUE
    TARKKA, IM
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 1984, 24 (03): : 189 - 194
  • [30] Comparison of surface electromyography and myotonometric measurements during voluntary isometric contractions
    Leonard, CT
    Brown, JS
    Price, TR
    Queen, SA
    Mikhailenok, EL
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (06) : 709 - 714