Voltage control scheme in distribution network with double feed induction generator wind farm

被引:0
|
作者
Zhao, Jingjing [1 ]
Li, Xin [1 ]
Hao, Jutao [2 ]
机构
[1] State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, 400044 Chongqing, China
[2] School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, 200093 Shanghai, China
来源
关键词
27;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:709 / 718
相关论文
共 50 条
  • [21] A Voltage Control Scheme in a Distribution Feeder with Wind Energy Sources
    Petinrin, J. O.
    Shaaban, Mohamed
    [J]. 2015 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2015, : 60 - 65
  • [22] Performance of a variable speed double-fed induction generator wind turbine during network voltage unbalance conditions
    Kearney, Joseph
    Conlon, Michael F.
    [J]. PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 36 - +
  • [23] Analysis of a variable speed double-fed induction generator wind turbine during network voltage unbalance conditions
    Kearney, Joseph
    Conlon, Michael F.
    [J]. 2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 1060 - 1064
  • [24] A new model for double output induction generator in wind farm using integral manifold theory
    Arzaghi-Harris, D
    Sedighizadeh, M
    Kalantar, M
    [J]. TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C456 - C459
  • [25] A STATCOM based control scheme for grid connected wind driven Induction Generator
    Sumathy, N.
    Prakash, S. Lenin
    [J]. 2012 THIRD INTERNATIONAL CONFERENCE ON COMPUTING COMMUNICATION & NETWORKING TECHNOLOGIES (ICCCNT), 2012,
  • [26] A Predictive Voltage Control Scheme For A Variable Speed Doubly Fed Induction Generator
    Mossa, Mahmoud A.
    Do, Ton Due
    Echeikh, Hamdi
    Diab, Ahmed A. Zaki
    [J]. 2021 IEEE 12TH ENERGY CONVERSION CONGRESS AND EXPOSITION - ASIA (ECCE ASIA), 2021, : 1491 - 1497
  • [27] Static compensator for maintaining voltage stability of wind farm integration to a distribution network
    Lahacani, N. Aouzellag
    Aouzellag, D.
    Mendil, B.
    [J]. RENEWABLE ENERGY, 2010, 35 (11) : 2476 - 2482
  • [28] Voltage Stability Indices Studies on Optimal Location of Wind Farm in Distribution Network
    Ismail, Bazilah
    Naain, Muhammad Mat
    Wahab, Noor Izzri Abdul
    Shaberon, Nur Syahidah Mohd
    Awalin, Lilik Jamilatul
    Alhamrouni, Ibrahim
    [J]. 2017 3RD IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2017, : 111 - 116
  • [29] Study on Adaptive Voltage Control Strategy of Double-Fed Wind Farm
    Cao, Na
    Jin, Ding
    Song, Zongen
    Chong, Kai
    Qi, Luxiang
    [J]. 2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 3565 - 3570
  • [30] The Robustness Test of the Double Fed Induction Generator Control Used in a Wind Fnergy Conversion System in the Voltage Dips Event
    Elmouhi, Noureddine
    Essadki, Ahmed
    Elaimani, Hind
    Chakib, Rachid
    [J]. 2018 6TH INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2018, : 358 - 363