Design of a low-cost force insoles to estimate ground reaction forces during human gait

被引:0
|
作者
Guevara, Nelson E. [1 ,2 ,3 ]
Rengifo, Carlos F. [1 ,2 ]
Bolanos, Yamir H. [3 ]
Fernandez, Daniel A. [1 ,2 ,3 ]
Sierra, Wilson A. [4 ]
Rodriguez, Luis E. [4 ]
机构
[1] Univ Cauca, Res Grp Automat, Popayan, Colombia
[2] Univ Cauca, Dept Elect Instrumentat & Control, Popayan, Colombia
[3] Corp Univ Autonoma Cauca, Fac Engn & Nat Sci, Popayan, Colombia
[4] Escuela Colombiana Ingn Julio Garavito, Fac Biomed Engn, Bogota, Colombia
来源
HARDWAREX | 2024年 / 20卷
关键词
Ground reaction forces; Force insoles; Piezo-resistive sensors; ESP32; microcontrollers; Low-cost; 3D printing; PRESSURE;
D O I
10.1016/j.ohx.2024.e00589
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a low-cost electronic system for estimating ground reaction forces (GRF) during human gait. The device consists of one master node and two slave nodes. The master node sends instructions to slave nodes that sample and store data from two force insoles located at the participant's feet. These insoles are equipped with 14 piezo-resistive FlexiForce A301 sensors (FSR). The slave nodes are attached to the ankles and feet of each participant. Subsequently, the start command is transmitted through the master node, which is connected to the USB port of a personal computer (PC). Once the walking session is completed, the information obtained by the slave nodes can be downloaded by accessing the access point generated by these devices through Wi-Fi communication. The GRF estimation system was validated with force platforms (BTS Bioengineering P6000, Italy), giving on average a fit measure equal to 68.71%+/- 4.80% in dynamic situations. Future versions of this device are expected to increase this fit by using machine learning models.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] A probabilistic method to estimate gait kinetics in the absence of ground reaction force measurements
    Tanghe, Kevin
    Afschrift, Maarten
    Jonkers, Ilse
    De Groote, Friedl
    De Schutter, Joris
    Aertbelien, Erwin
    JOURNAL OF BIOMECHANICS, 2019, 96
  • [22] Ground reaction forces during human standing
    Shimba, T.
    Engineering in Medicine, 1983, 12 (04): : 177 - 182
  • [23] Ground reaction force and EMG responses during gait in treadmill
    Sacco, ICN
    Serrao, JC
    Sá, MR
    Amadio, AC
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 112 - 112
  • [24] ASYMMETRIES IN GROUND REACTION FORCE PATTERNS IN NORMAL HUMAN GAIT
    HERZOG, W
    NIGG, BM
    READ, LJ
    OLSSON, E
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1989, 21 (01): : 110 - 114
  • [25] Computation of Ground Reaction Forces During Gait using Kinematic Data
    Song, Sung Jae
    Kim, Sei Yoon
    Kim, Young Tae
    Lee, Sang Don
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2010, 34 (04) : 431 - 437
  • [26] Foot landing position during gait influences ground reaction forces
    Simpson, KJ
    Jiang, P
    CLINICAL BIOMECHANICS, 1999, 14 (06) : 396 - 402
  • [27] Design and testing of a high-speed treadmill to measure ground reaction forces at the limit of human gait
    Bundle, Matthew W.
    Powell, Michael O.
    Ryan, Laurence J.
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (09) : 892 - 897
  • [28] Force plate analysis of ground reaction forces in relation to gait velocity of healthy Beagles
    Ichinohe, Tom
    Takahashi, Hiromi
    Fujita, Yukihiro
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2022, 83 (09)
  • [29] Ground reaction forces of the canine hindlimb: Are there differences between gait on treadmill and force plate?
    Drueen, Svenja
    Boeddeker, Jasmin
    Nolte, Ingo
    Wefstaedt, Patrick
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 2010, 123 (7-8): : 339 - 345
  • [30] Influence of insole materials on friction and ground reaction force during gait
    Pauk, J.
    Tolstoj-Sienkiewicz, J.
    Ihnatouski, M.
    Kuzmierowski, T.
    Chojnowski, E.
    JOURNAL OF FRICTION AND WEAR, 2015, 36 (04) : 319 - 323