A novel ratiometric fluorescent nanosensor based-on UiO-66-NH2 capped carbon dots for nitrite determination

被引:1
|
作者
He, Ming-Qin [1 ,2 ]
Li, Hong-Wei [1 ,2 ]
Wu, Yuqing [1 ,2 ]
机构
[1] Jilin Univ, Coll Chem, State Key Lab Supramol Struct & Mat, 2699 Qianjin St, Changchun 130012, Peoples R China
[2] Jilin Univ, Inst Theoret Chem, Coll Chem, 2 Liutiao Rd, Changchun 130023, Peoples R China
关键词
Nitrite determination; CDs; UiO-66-NH2; Ratiometric fluorescence; METAL-ORGANIC FRAMEWORK;
D O I
10.1016/j.saa.2024.125422
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Nitrite is a commonly used food preservative and a water contaminant that has garnered significant attention due to its harmful effects on human health. Developing a simple and sensitive method for determining nitrite levels is crucial for safeguarding public health. In this paper, we present a novel ratiometric fluorescent nanosensor (CDs@UiO-66-NH2), created by combining orange-red-emitting CDs with blue-emitting UiO-66-NH2. This ratiometric probe detects nitrite ions (NO2-) based on the diazotization reaction between the amino group in UiO-66-NH2 and the target NO2-, where the blue emission of UiO-66-NH2 is quenched but the orange-red emission of CDs remains stable. The probe demonstrated a detection range of 0.5-20 mu M with a limit of detection (LOD) of 0.157 mu M for NO2-. Due to the probe's distinct color changes in response to NO2-, RGB values can be easily read using a smartphone, enabling ultrasensitive visual detection of NO2- with an LOD of 0.76 mu M. This sensor was successfully applied to detect NO2- in environmental water samples. Finally, a smartphone-based RGB reading method using CDs@UiO-66-NH2 for visual quantitative detection of NO2- was proposed, broadening the application of CDs@UiO-66-NH2 in environmental protection.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A novel electrochemical sensor based on AuPd/UiO-66-NH2/GN composites for sensitive dopamine detection
    Zhou, Ying
    Li, Ruichun
    Zhang, Guomei
    Zhang, Yan
    Zhang, Caihong
    Shuang, Shaomin
    ANALYST, 2022, 147 (24) : 5655 - 5662
  • [22] A fluorescent sensor based on pentafluoropropanoic acid-functionalized UiO-66-NH2 for enhanced selectivity and sensitivity of dicloran detection
    Sun, Xueqin
    Fan, Yan
    Zhang, Wenyuan
    Yang, Xiaogang
    Liu, Jiacheng
    MICROCHIMICA ACTA, 2025, 192 (02)
  • [23] Metal-organic framework (UiO-66 and UiO-66-NH2)-based adsorbents for bilirubin removal used in hemoperfusion
    Liu, Yi
    Yuan, Zhipeng
    Chen, Yanrong
    RSC ADVANCES, 2023, 13 (50) : 35078 - 35087
  • [24] Adsorptive removal of Cr(VI) onto UiO-66-NH2 and its determination by radioanalytical techniques
    Suraj Prakash Tripathy
    Satyabrata Subudhi
    Rashmi Acharya
    Raghunath Acharya
    Mira Das
    Kulamani Parida
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 322 : 983 - 992
  • [25] UiO-66-NH2 and Zeolite-Templated Carbon Composites for the Degradation and Adsorption of Nerve Agents
    Lee, Jaeheon
    Ka, Dongwon
    Jung, Heesoo
    Cho, Kyeongmin
    Jin, Youngho
    Kim, Minkun
    MOLECULES, 2021, 26 (13):
  • [26] Adsorptive removal of Cr(VI) onto UiO-66-NH2 and its determination by radioanalytical techniques
    Tripathy, Suraj Prakash
    Subudhi, Satyabrata
    Acharya, Rashmi
    Acharya, Raghunath
    Das, Mira
    Parida, Kulamani
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (02) : 983 - 992
  • [27] Dual-emissive EY/UiO-66-NH2 as a ratiometric probe for turn-on sensing and cell imaging of hypochlorite
    Yu, Fangfang
    Wang, Yihan
    Liu, Tengfei
    Liu, Xiaohui
    Jiang, Hui
    Wang, Xuemei
    ANALYST, 2022, 147 (17) : 3867 - 3875
  • [28] New Chemistry for Mixed Matrix Membranes: Growth of Continuous Multilayer UiO-66-NH2 on UiO-66-NH2-Based Polyacrylonitrile for Highly Efficient Separations
    Aghili, Fatemeh
    Ghoreyshi, Ali Asghar
    Rahimpour, Ahmad
    Van der Bruggen, Bart
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (16) : 7825 - 7838
  • [29] A dual-functional fluorescent nanoprobe based on UIO-66-NH2 for the continuous detection of o-phenylenediamine and Ag+
    Si, Yanmei
    Li, Yansong
    Zhou, Ranxu
    Zhang, Xin
    Liu, Wei
    Yue, Duyuan
    Yan, Yehao
    NEW JOURNAL OF CHEMISTRY, 2024, 48 (45) : 19096 - 19100
  • [30] A metal organic framework, UiO-66-NH2, based on a molybdenum Schiff base complex for the efficient electrochemical determination of diphenoxylate
    Saeednia, Samira
    Rezaeinasab, Masoud
    Iranmanesh, Parvaneh
    Razgaleh, Sobhan Abbasi
    ANALYTICAL METHODS, 2024, : 762 - 771