Analysis of flow instabilities for once-through steam generator

被引:0
|
作者
State Key Laboratory of Multiphase Flow, Xi'an Jiaotong University, Xi'an 710049, China [1 ]
不详 [2 ]
机构
来源
Hedongli Gongcheng | 2008年 / 5卷 / 43-47期
关键词
Heat transfer and flows - Laplace transformations - Nyquist stability criterion - Once through steam generator - Perturbation theory - Resistance factors - Stability analysis - Two-phase flow instabilities;
D O I
暂无
中图分类号
学科分类号
摘要
This paper analyzes the two-phase flow instabilities in parallel tubes using frequency domain control theory for steam generator in order to disclose the mechanism of flow instability. The mathematics expressions of heat transfer and flow of steam generator are proposed, and the eigenfunction of the close loop system is deduced using linearize perturbation theory and Laplace transformation. System stability is judged by Nyquist stability criterion of automatic control theory. On the above bases, the computer code is derived, and the stability analysis of steam generator is made by using this code. The results show that there is certain relations between the system stability and the channel number. The increasing of entrance resistance factor enhances the system stability; and the reducing of operation load impairs the system stability gradually.
引用
收藏
相关论文
共 50 条
  • [21] Load following dynamic characteristic analysis of casing once-through steam generator
    Liu, Jian-Ge
    Peng, Min-Jun
    Zhang, Zhi-Jian
    Xu, Wen-Qi
    Cheng, Shou-Yu
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (02): : 175 - 182
  • [22] Numerical Simulation of Full Range Flow and Heat Transfer in Once-through Steam Generator
    Shi J.-X.
    Sun B.-Z.
    Yu X.
    Zhao Y.-J.
    Liu S.-H.
    [J]. 2017, Atomic Energy Press (51): : 425 - 431
  • [23] Structural integrity confirmation of a once-through steam generator from the viewpoint of flow instability
    Kang, Han-Ok
    Seo, Jae-Kwang
    Kim, Yong Wan
    Yoon, Juhyeon
    Kim, Keungkoo
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2007, 44 (01) : 64 - 72
  • [24] Analysis of steady-state characteristics of casing once-through steam generator
    Liu, Jian-Ge
    Peng, Min-Jun
    Zhang, Zhi-Jian
    Li, Hua
    [J]. Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2009, 30 (07): : 757 - 762
  • [25] Failure Analysis of Once-Through Steam Generator (OTSG) External Piping Welds
    Saini, Nitin
    Wang, Yajing
    Li, Leijun
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (03) : 1180 - 1195
  • [26] Numerical studies of a helical coil once-through steam generator
    Xia, Genglei
    Yuan, Yuan
    Peng, Minjun
    Lv, Xing
    Sun, Lin
    [J]. ANNALS OF NUCLEAR ENERGY, 2017, 109 : 52 - 60
  • [27] Multiple Models Predictive Control of Once-Through Steam Generator
    Tai Yun
    Hou Su-xia
    Zhao Fu-yu
    [J]. ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 3, 2008, : 993 - 1000
  • [28] ONCE-THROUGH STEAM GENERATOR BOOSTS PWR CYCLE EFFICIENCY
    SANKOVICH, MF
    MCDONALD, BN
    [J]. NUCLEAR ENGINEERING INTERNATIONAL, 1972, 17 (194): : 546 - +
  • [29] DYNAMIC MODELING OF A LARGE ONCE-THROUGH STEAM-GENERATOR
    SANATHANAN, CK
    SANDBERG, AA
    CLARK, FH
    BURKE, OW
    STONE, RS
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1972, 23 (03) : 321 - 330
  • [30] FUNDAMENTAL STUDY OF ONCE-THROUGH STEAM-GENERATOR DYNAMICS
    COULMAN, GA
    GOTTLIEB, I
    [J]. SIMULATION, 1976, 26 (04) : 124 - 124