Development of smart sensor for ultra-high-frequency partial discharge detection

被引:0
|
作者
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing [1 ]
400030, China
不详 [2 ]
650217, China
不详 [3 ]
330096, China
机构
来源
Gaodianya Jishu | / 12卷 / 3944-3951期
基金
中国国家自然科学基金;
关键词
Hilbert fractal antennas - Parasitic conductor - Scanning methods - Stacked structure - UHF detection;
D O I
10.13336/j.1003-6520.hve.2015.12.010
中图分类号
学科分类号
摘要
To satisfy the requirements of ultra-high frequency (UHF) partial discharge on-line monitoring, we proposed a novel smart sensor for UHF partial discharge online detection based on stacked multiple-arm Hilbert fractal antenna and level scanning system. Moreover, we improved the traditional Hilbert fractal patch by adding parasitic arm and cascading patch structure, and designed a cascading multiple-arm Hilbert fractal antenna with small size, wide frequency band and high gain, which was used as the antenna of smart sensor. The level scanning module for data collection obtained by level scanning method was used as the data acquisition unit of smart sensor. The needle-plate discharge experiment in air was carried out in laboratory, and the full waveform signal sample method and the smart sensor were used to capture and process the signal simultaneously. The experimental results show that the proposed smart sensor can process the UHF partial discharge signal quickly and directly, output the partial discharge figures with small amount of output data, and lower the cost of hardware and small volume of equipment. The discharge figures obtained by the two methods are nearly same, which proves that the smart sensor can capture and process the partial discharge signal accurately. © 2015, High Voltage Engineering Editorial Department of CEPI. All right reserved.
引用
收藏
相关论文
共 50 条
  • [1] Partial discharge detection in GIS using ultra-high-frequency method
    Sun, Yanzhou
    Wang, Xudong
    Yin, Hua
    Yu, Fashan
    [J]. ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 695 - +
  • [2] Application of ultra-high-frequency partial discharge detection in power transformers
    Zhao, Xiao-Hui
    Lu, Xiu-Li
    Yang, Jing-Gang
    Yuan, Peng
    Li, Yan-Ming
    [J]. Gaodianya Jishu/High Voltage Engineering, 2007, 33 (08): : 111 - 114
  • [3] Ultra-high-frequency Partial Discharge Detection with Scanning and Comparing Method
    Yan, Jinping
    Du, Lin
    Li, Jian
    Wang, Youyuan
    [J]. 2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [4] Experimental Investigation of Partial Discharge Detection in Medium-voltage Switchgear Based on Ultra-High-Frequency Sensor
    Wang, Liuhuo
    Ning, Wenjun
    Wang, Lijun
    Lu, Hong
    Wang, Haijing
    Jia, Shenli
    Wu, Ji
    [J]. 2013 2ND INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2013,
  • [5] An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers
    Li, Jian
    Li, Xudong
    Du, Lin
    Cao, Min
    Qian, Guochao
    [J]. ENERGIES, 2016, 9 (05)
  • [6] Development of multi-band ultra-high-frequency sensor for partial discharge monitoring based on the meandering technique
    Ye Hai-feng
    Qian Yong
    Dong Yue
    Sheng Ge-hao
    Jiang Xiu-chen
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2014, 8 (05) : 327 - 335
  • [7] Study on the Application of an Ultra-High-Frequency Fractal Antenna to Partial Discharge Detection in Switchgears
    Yao, Chenguo
    Chen, Pan
    Huang, Congjian
    Chen, Yu
    Qiao, Panpan
    [J]. SENSORS, 2013, 13 (12): : 17362 - 17378
  • [8] Detection and Analysis of Partial Discharge using Ultra High Frequency Sensor
    Reddy, P. Gurumurthy
    Kundu, Prasanta
    [J]. 2014 ANNUAL INTERNATIONAL CONFERENCE ON EMERGING RESEARCH AREAS: MAGNETICS, MACHINES AND DRIVES (AICERA/ICMMD), 2014,
  • [9] New ultra high frequency sensor for detection of partial discharge for GIS
    Hu, Di-Jun
    Chen, Jie-Hua
    Li, Zhong
    Feng, Yun-Ping
    [J]. Gaoya Dianqi/High Voltage Apparatus, 2003, 39 (04):
  • [10] Partial discharge detection for GIS using narrow band ultra-high-frequency (UHF) method
    Sun, YZ
    Yin, H
    Zhang, QG
    Yu, FS
    Wang, H
    Qiu, YC
    [J]. Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 748 - 751