Interference removal in mass spectrometry for the determination of trace gold,mercury and selenium in nickel-based superalloys by ICP-MS/MS

被引:0
|
作者
Wang, Zhaoying [1 ,2 ]
Chen, Xiongfei [1 ]
Xu, Yan [3 ]
Mo, Shumin [1 ]
Zhang, Fang [1 ]
Tong, Jian [1 ]
Liu, Ying [1 ]
机构
[1] Guobiao (Beijing)Testing and Certification Co.,Ltd, National Analysis and Testing Center of Nonferrous Metals and Electronic Materials, Beijing,101407, China
[2] Beijing General Research Institute for Nonferrous Metals, Beijing,100088, China
[3] China National Accreditation Service for Conformity Assessment, Beijing,100062, China
关键词
Beryllium alloys - Cerium alloys - Cesium alloys - Gold alloys - Hafnium alloys - Inductively coupled plasma mass spectrometry - Levitation melting - Nickel - Nickel oxide - Nitrogen - Rhodium alloys - Selenium - Sulfur - Tantalum - Tantalum alloys - Zinc;
D O I
10.13595/j.cnki.issn1000-0720.2023053103
中图分类号
学科分类号
摘要
:The traditional single-quad inductively coupled plasma mass spectrometry(ICP-MS)cannot eliminate the mass spectrometry interference caused by the polyatomic ions formed by Ta,W and Ni elements and carrier gas Ar in the determination of trace impurity elements Au,Hg and Se in the second-generation nickel-based single crystal high-temperature alloy CMSX-4. Based on triple quadrupole-inductively coupled plasma mass spectrometry (ICP-MS/MS)technology,the working conditions of the instrument were studied by investigating the effects of mass spectrum interference cancellation under different collision or reaction modes (No Gas mode, He mode,O2 on-mass mode,and O2 mass-shift mode). A method was established for the determination of trace impurity elements Au,Hg and Se in CMSX-4. The results showed that the mass spectrometry interference of TaO+ on Au+ and WO+ on Hg+ can be effectively eliminated by using O2 on-mass mode;the mass spectrometry interference of NiO+ and ArAr+ on Se+ can be effectively eliminated by using O2 mass-shift mode. Considering the signal intensities and background equivalent concentrations of the 3 elements to be measured,the O2 flow rate was determined to be 0.60 mL/min. Also,133 Cs was selected as the internal standard element for the measurement of Au and Hg,while103 Rh was selected for the measurement of Se after comparing the effects of correcting matrix effects and analyte signal drift by internal standard elements. The linear equations of Au,Hg and Se have been established under the optimal conditions,and the linear correlation coefficients were 0.9991. The detection limits of Au,Hg,and Se were 0.11-0.29 ng/mL. The relative standard deviations (RSDs)were 2.0%-9.5%,and the spiked recoveries of Au and Hg were 96.1%-107.2% by determining the samples of 3 supplemental levels and the recoveries of the bidding recycling of 9 groups. The results showed no significant difference between the identification value by t-test of Se in the standard substance in the nickel-based high-temperature alloys. © 2024, Youke Publishing Co.,Ltd. All rights reserved.
引用
收藏
页码:1183 / 1189
相关论文
共 50 条
  • [21] Facilitation of trace elemental determination in plutonium oxide by inductively coupled plasma mass spectrometry (ICP-MS)
    Giglio, J
    Cummings, D
    Krsul, J
    PLUTONIUM FUTURES - THE SCIENCE, 2003, 673 : 116 - 116
  • [22] Interference-free determination of ultra-trace concentrations of arsenic and selenium using methyl fluoride as a reaction gas in ICP-MS/MS
    Bolea-Fernandez, Eduardo
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) : 919 - 929
  • [23] ICP-MS analysis of trace selenium in the Great Salt Lake
    Moellmer, William O.
    Miller, Theron G.
    Wilbur, Steve
    Soffey, Emmett
    Spectroscopy (Santa Monica), 2007, 22 (01) : 32 - 41
  • [24] ICP-MS analysis of trace selenium in the Great Salt Lake
    Moellmer, William O.
    Miller, Theron G.
    Wilbur, Steve
    Soffey, Emmett
    SPECTROSCOPY, 2007, 22 (01) : 32 - +
  • [25] Mercury determination with ICP-MS: signal suppression by acids
    L. Jian
    W. Goessler
    K. J. Irgolic
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 48 - 53
  • [26] The determination of mercury in microwave digests of foodstuffs by ICP-MS
    Entwisle, J
    AMERICAN LABORATORY, 2004, 36 (06) : 11 - +
  • [27] Inductively coupled plasma - Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra) trace elements - A tutorial review
    Balcaen, Lieve
    Bolea-Fernandez, Eduardo
    Resano, Martin
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2015, 894 : 7 - 19
  • [28] Mercury determination with ICP-MS: signal suppression by acids
    Jian, L
    Goessler, W
    Irgolic, KJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (01): : 48 - 53
  • [29] Determination of Trace Impurities in Silicon Carbide by ICP-MS
    Naka, H.
    Kurayasu, H.
    Bunseki Kagaku, 45 (12):
  • [30] Accurate determination of trace silver in geological reference materials by inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)
    Li, Jiawei
    Zong, Keqing
    Yan, Dong
    Du, Yaowei
    Wang, Zaicong
    Gao, Wei
    Li, Ming
    Lin, Jie
    Zhang, Wen
    Chen, Haihong
    Hu, Zhaochu
    Liu, Yongsheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (10) : 1984 - 1994