Comparative analysis of hybrid geothermal-solar systems and solar PV with battery storage: Site suitability, emissions, and economic performance

被引:0
|
作者
Fedakar, Halil Ibrahim [1 ]
Dinçer, Ali Ersin [2 ]
Demir, Abdullah [3 ]
机构
[1] Department of Civil Engineering, Transportation Laboratory Abdullah Gul University, Kayseri,38080, Turkey
[2] Department of Civil Engineering, Hydraulics Laboratory Abdullah Gul University, Kayseri,38080, Turkey
[3] Department of Civil Engineering, Structural Eng. Laboratory, Abdullah Gul University, Kayseri,38080, Turkey
关键词
Carbon capture and utilization - Carbon sequestration;
D O I
10.1016/j.geothermics.2024.103175
中图分类号
学科分类号
摘要
Renewable energy integration has become a critical focus in the global effort to reduce carbon emissions and diversify energy sources. In regions with distinct geographic features, such as Türkiye, combining different renewable technologies can offer enhanced energy security. This study investigates the site suitability and economic and environmental performance of hybrid geothermal-solar systems and solar PV systems with battery storage across the provinces of Osmaniye, Hatay, and Kilis, of Türkiye. Using the fuzzy-AHP method, site suitability is evaluated, addressing a key gap in comparing these systems' adaptability to varying geographic conditions. This study is the first to directly compare these two renewable energy technologies in terms of site suitability. The findings reveal significant differences in site suitability, with solar PV systems with battery storage demonstrating broader applicability across the region. The suitable sites (20–100 % suitability) cover 1260.82 km² for solar PV systems with battery storage and only 122.18 km² for hybrid geothermal-solar systems. In terms of environmental impact, hybrid geothermal-solar systems exhibit significantly lower carbon emissions, averaging 44.6 kg CO₂/MWh, compared to 123.8 kg CO₂/MWh for solar PV systems with battery storage. Economically, hybrid geothermal-solar systems also outperform with a lower levelized cost of electricity of $0.091 kWh versus $0.254 kWh for solar PV systems. These results highlight the environmental and economic advantages of hybrid geothermal-solar systems, while also emphasizing their limited scalability to regions with geothermal activity. Conversely, solar PV systems, despite their higher emissions and costs, offer greater flexibility and potential for widespread deployment. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [21] Comparative study of photovoltaic and thermal solar systems with different storage capacities: Performance evaluation and economic analysis
    Bhattarai, Sujala
    Kafle, G. P. Krishna
    Euh, Seung-Hee
    Oh, Jae-Heun
    Kim, Dae Hyun
    ENERGY, 2013, 61 : 272 - 282
  • [22] Design of UPQC with Solar PV and Battery Storage Systems for Power Quality Improvement
    Srilakshmi, Koganti
    Jyothi, K. Krishna
    Kalyani, G.
    Goud, Y. Sai Prakash
    CYBERNETICS AND SYSTEMS, 2023,
  • [23] Current and future prospective for battery controllers of solar PV integrated battery energy storage systems
    Hasan, Mustafa
    Serra Altinoluk, H.
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [24] Performance Analysis and Optimization of a Hybrid Solar Geothermal Power Plant
    Maali, Rafika
    Khir, Tahar
    Ben Brahim, Ammar
    RECENT ADVANCES IN ENVIRONMENTAL SCIENCE FROM THE EURO-MEDITERRANEAN AND SURROUNDING REGIONS, VOLS I AND II, 2018, : 1581 - 1584
  • [25] Conventional and Advanced Exergy-Based Analysis of Hybrid Geothermal-Solar Power Plant Based on ORC Cycle
    Alibaba, Massomeh
    Pourdarbani, Razieh
    Manesh, Mohammad Hasan Khoshgoftar
    Herrera-Miranda, Israel
    Gallardo-Bernal, Ivan
    Hernandez-Hernandez, Jose Luis
    APPLIED SCIENCES-BASEL, 2020, 10 (15):
  • [26] Performance Analysis of a Rooftop Hybrid Connected Solar PV Syste
    Falih H.
    Hamed A.J.
    Khalifa A.H.N.
    Energy Engineering: Journal of the Association of Energy Engineering, 2022, 119 (04): : 1729 - 1744
  • [27] Thermodynamic, exergo-economic and exergo-environmental analysis of hybrid geothermal-solar power plant based on ORC cycle using emergy concept
    Alibaba, Massomeh
    Pourdarbani, Razieh
    Manesh, Mohammad Hasan Khoshgoftar
    Ochoa, Guillermo Valencia
    Forero, Jorge Duarte
    HELIYON, 2020, 6 (04)
  • [28] Technical and Economic Analysis of Battery Storage for Residential Solar Photovoltaic Systems in the Brazilian Regulatory Context
    Deotti, Lucas
    Guedes, Wanessa
    Dias, Bruno
    Soares, Tiago
    ENERGIES, 2020, 13 (24)
  • [29] Analysis and Optimization of a Geothermal, Biomass, Solar Hybrid System: An Application of PV*Sol Software
    Patarau, Toma
    Petreus, Dorin
    Etz, Radu
    2015 38TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE 2015), 2015, : 370 - 375
  • [30] Comparative analysis of solar-battery storage sizing in net metering and zero export systems
    Kumar, Piyush
    Malik, Nitin
    Garg, Anjali
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2022, 69 : 41 - 50