Module development and energy simulation analysis of the variable refrigerant volume system based on energyplus

被引:0
|
作者
Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China [1 ]
机构
来源
Xitong Fangzhen Xuebao | 2007年 / 20卷 / 4808-4811期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate energy consumption features of the new-generation variable refrigerant volume (VRV-II) system, an energy calculation module for the system was developed based on the dynamic building energy simulation program, EnergyPlus. A building energy comparison analysis among the VRV system and several popular air conditioning systems was implemented, using a typical commercial building model. Simulation results show that the VRV system is the most energy-efficient plan. For the traditional systems, the water-cooled screw chiller is more energy efficient than the air-cooled screw chiller as the plant scheme, and the Fan-coil plus outdoor-air system are found more energy efficient than the variable-air-volume system as the system plan.
引用
收藏
相关论文
共 50 条
  • [41] Development and validation of an HVAC on/off controller in EnergyPlus for energy simulation of residential and small commercial buildings
    Cetin, Kristen S.
    Fathollahzadeh, Mohammad Hassan
    Kunwar, Niraj
    Huyen Do
    Tabares-Velasco, Paulo Cesar
    ENERGY AND BUILDINGS, 2019, 183 : 467 - 483
  • [42] Energy use analysis of the variable refrigerant flow (VRF) system versus the multi - split unit using TRNSYS
    Y. H. Yau
    M. ‘Amir
    Heat and Mass Transfer, 2020, 56 : 671 - 690
  • [43] Comparative energy analysis of a constant air volume (CAV) system and a variable air volume (VAV) system for a software laboratory
    Refrigeration and Air Conditioning Division, Department of Mechanical Engineering, Anna University, Chennai, India
    不详
    Int. J. Vent., 2006, 2 (229-237):
  • [44] Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions
    Li, Yueming
    Wu, Jingyi
    Shiochi, Sumio
    ENERGY AND BUILDINGS, 2009, 41 (09) : 949 - 957
  • [45] Development of an Optimal Start Control Strategy for a Variable Refrigerant Flow (VRF) System
    Lee, Yusung
    Kim, Woohyun
    ENERGIES, 2021, 14 (02)
  • [46] Heat Recovery Variable Refrigerant Volume System Installation and Experiences from its Summer Operation
    Strakova, Zuzana
    Vojtassak, Jozef
    Takacs, Jan
    Kurcova, Maria
    Stefanic, Pavol
    Malisek, Samuel
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 2024, 68 (01): : 1 - 5
  • [47] Design and Development of Variable Rate Spraying System Based on Canopy Volume Measurement
    Hu, Kaiqun
    Fu, Zetian
    Ji, Ronghua
    Wang, Jun
    Qi, Lijun
    COMPUTER AND COMPUTING TECHNOLOGIES IN AGRICULTURE V, PT I, 2012, 368 : 402 - +
  • [48] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916
  • [49] Design framework for variable refrigerant flow systems with enhancement of interoperability between BIM and energy simulation
    Choi, Myunghwan
    Cho, Sangeun
    Lim, Jinsung
    Shin, Hyoungsub
    Li, Zhi
    Kim, Jay J.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (12) : 6009 - 6019
  • [50] Design framework for variable refrigerant flow systems with enhancement of interoperability between BIM and energy simulation
    Myunghwan Choi
    Sangeun Cho
    Jinsung Lim
    Hyoungsub Shin
    Zhi Li
    Jay J. Kim
    Journal of Mechanical Science and Technology, 2018, 32 : 6009 - 6019