A ventilated cooling ceiling with integrated latent heat storage - Monitoring results

被引:0
|
作者
机构
[1] Weinläder, Helmut
[2] Körner, Werner
[3] Strieder, Birgit
来源
Weinläder, Helmut | 1600年 / Elsevier Ltd卷 / 82期
关键词
Storage (materials) - Cooling - Heat storage - Latent heat - Ceilings - Ventilation - Energy efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
A ventilated cooling ceiling with integrated phase change material (PCM) as latent heat storage was installed in two offices and a conference room. The ceiling was rear ventilated to improve the heat transfer between PCM and room air and its cooling properties were monitored during summer 2009 and 2010. During the day, the ventilation was purely in circulating operation, while cool outside air was used during the night to regenerate the PCM. The ventilated ceiling with PCM reduced the maximum operative room temperature in the office rooms by up to 2 K compared to a reference room without cooling system. For an operative room temperature of 28 °C and a volume flow rate of 300 m3/h, a cooling power of 30 W/m2 was measured in the conference room. In the demonstration rooms, it was not possible to insert the fresh air directly onto the PCM as planned. Instead, the outer air entered the rooms via tilted windows or ventilation flaps in the façade, so the cool night air did not reach the suspended ceiling but instead sank to the floor and mixed with the warmer room air. Due to this, the PCM in the suspended ceiling often could not be regenerated completely. © 2014 Elsevier B.V. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [21] Transient heat transfer characteristics of cooling fluid loop with latent heat storage unit
    Zhang, Xuan
    Li, Bo
    Yu, Cheng
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [22] PERFORMANCE OF SOLAR SORPTION COOLING SYSTEMS WITH HEAT REJECTION ASSISTED BY A LATENT HEAT STORAGE
    Hagel, K.
    Helm, M.
    Schweigler, C.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2856 - 2863
  • [23] Thermal performance of a latent heat energy storage ventilated panel for electric load management
    Laouadi, A
    Lacroix, M
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (02) : 275 - 286
  • [24] Numerical Study of a Ventilated Room: Effect of Heating Floor and Cooling Ceiling
    Khattari, Youness
    Benghoulam, Mahjoub
    Arid, Ahmed
    Elrhafiki, Tank
    PROCEEDINGS OF 2017 INTERNATIONAL RENEWABLE & SUSTAINABLE ENERGY CONFERENCE (IRSEC' 17), 2017, : 974 - 979
  • [25] Application of a phase change material to a thermoelectric ceiling radiant cooling panel as a heat storage layer
    Lim, Hansol
    Kang, Yong-Kwon
    Jeong, Jae-Weon
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [26] Latent heat storage
    Schatz, Oskar
    Nader, Frederick R.
    Ross, Steven
    Automotive Engineering International, 1992, 100 (02): : 58 - 61
  • [27] Low-energy resilient cooling through geothermal heat dissipation and latent heat storage
    Mehmood, Sajid
    Lizana, Jesus
    Friedrich, Daniel
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [28] Numerical simulation of porous latent heat thermal energy storage for thermoelectric cooling
    Trelles, JP
    Dufly, JJ
    APPLIED THERMAL ENGINEERING, 2003, 23 (13) : 1647 - 1664
  • [29] PERFORMANCE CHARACTERISTICS OF A NATURAL CIRCULATION COOLING/LATENT HEAT STORAGE SYSTEM.
    Sakitani, Katsumi
    Sahara, Yoshio
    Honda, Hiroshi
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1987, 53 (493): : 2857 - 2862
  • [30] Development of salt hydrate eutectics as latent heat storage for air conditioning and cooling
    Efimova, Anastasia
    Pinnau, Sebastian
    Mischke, Matthias
    Breitkopf, Cornelia
    Ruck, Michael
    Schmidt, Peer
    THERMOCHIMICA ACTA, 2014, 575 : 276 - 278