A new approach of fault line detection in small current grounding system

被引:0
|
作者
Li, Bo [1 ]
机构
[1] Electronics and Information Engineering College, Liaoning University of Technology, No. 169, Shiying Street, Guta District, Jinzhou 121001, China
来源
ICIC Express Letters | 2014年 / 8卷 / 06期
关键词
Frequency domain analysis - Fault detection - Time domain analysis;
D O I
暂无
中图分类号
学科分类号
摘要
To improve accuracy of the existing fault line detection (FLD) method and seek a universal detection approach for both neutral non-grounding system (NUS) and neutral grounding system via arc-suppression coil (NES), we discuss a new approach applying Dempster-Shafer (D-S) evidence theory in this paper. First, the mechanism of single-phase-to-ground (SPTG) fault is presented. For small current grounding system (SCGS), the mathematical analysis on zero-sequence current is implemented. Afterwards, the criterion on magnitude-comparison of zero-sequence current in frequency domain and the criterion on amplitude-comparison of the fifth harmonic in time domain are proposed. Further, a multi-criterion FLD approach integrated D-S evidence theory is advanced. The simulation results confirm the reliability of our proposed approach. © 2014 ISSN 1881-803X.
引用
收藏
页码:1703 / 1709
相关论文
共 50 条
  • [41] Research on fault location method in small current grounding system based on active protection
    Cao Jingjin
    Lu Jiayang
    Lu Dongyang
    Zhang Na
    Yu Hua
    Han Yu
    2017 4TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE), 2017, : 1158 - 1162
  • [42] A composite ground faulted line detection device in small current neutral grounding network
    Zhongshan Polytechnic, Zhongshan 528404, China
    Gaoya Dianqi, 2007, 4 (298-300+303):
  • [43] Fault line detection based on rough set theory in indirectly grounding power system
    Pang, Qing-Le
    Sun, Tong-Jing
    Zhong, Mai-Ying
    Yang, Fu-Gang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (04): : 60 - 64
  • [44] Fault Line Detection Method for Flexible Grounding System Based on Changes of Phase Difference Between Zero Sequence Current and Voltage
    Li J.
    Li Y.
    Wang W.
    Song J.
    Zhang Y.
    Dianwang Jishu/Power System Technology, 2021, 45 (12): : 4847 - 4855
  • [45] Fault line detection method for a flexible grounding system based on a zero-sequence current amplitude ratio multiplication coefficient
    Zhou Y.
    Tang T.
    Zeng X.
    Luo C.
    Yang Z.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (23): : 112 - 120
  • [46] Research and Application of Monitoring Method of Small Current Grounding Fault in Distribution Line Based on Cloud Computing
    Hua Guanghui
    Chen Mingjia
    Liu Haixuan
    Ye Rongbo
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1363 - 1369
  • [47] Study on Detection of Grounding Capacitive Current in Resonance Grounding System
    Yu, Meng
    Lian, Huan
    Pan, Peiming
    COMPUTING, CONTROL AND INDUSTRIAL ENGINEERING IV, 2013, 823 : 546 - 549
  • [48] Reduction of the fault current passing through the grounding system of an HV substation supplied by cable line
    Popovic, Ljubivoje M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 99 : 493 - 499
  • [49] Simulation on Faulty Line Selection of Small Current Grounding System Based on Wavelet Transform
    Dou, Xinyu
    Li, Chunming
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [50] High Impedance Grounding Fault Detection in Resonance Grounding System Based on Nonlinear Distortion of Zero-sequence Current
    Zhu, Jiran
    Haiguo, Tang
    Leng, Hua
    Sun, Jiao
    Huang, Chun
    2020 5TH INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA 2020), 2020, : 74 - 78