Influence of core window height on thermal characteristics of dry-type transformers

被引:0
|
作者
Dawood, Kamran [1 ]
Kul, Seda [2 ]
机构
[1] Astor Enerji, Dept Res & Dev, Ankara, Turkiye
[2] Karamanoglu Mehmetbey Univ, Elect & Elect Engn Dept, Karaman, Turkiye
关键词
Core window; Dry-type transformer; Finite element analysis; Thermal analysis; Power transformer; TEMPERATURE; PERFORMANCE; EFFICIENCY; ONAN;
D O I
10.1016/j.csite.2025.105746
中图分类号
O414.1 [热力学];
学科分类号
摘要
Elevated temperatures in transformer windings and cores pose a significant risk of damage to power transformers. The objective of this work is to analyze the influence of core window dimensions on the thermal efficiency of power transformers. Analytical approaches are limited in their ability to consider the impact of core window dimensions on the transformer's thermal behavior. Conversely, experimental methods are both expensive and time-consuming. To overcome these constraints, this work assesses and optimizes the temperature distribution in dry-type power transformers using finite element models, specifically examining the impact of the core window. The thermal model treats core and winding losses as sources of heat generation. Four different transformers, with varying heights of the transformer core window, have been modeled to assess the impact of window height on the thermal conditions of the transformers. The simulation findings indicate that variations in core window height have a significant impact on the transformer's thermal properties. By comparing the model's predictions of short-circuit impedance with experimental data, this study demonstrates the model's capability to reliably estimate parameters influenced by core window variations, thereby validating its usefulness.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Analysis of temperature distribution in cast-resin dry-type transformers
    Rahimpour, Ebrahim
    Azizian, Davood
    ELECTRICAL ENGINEERING, 2007, 89 (04) : 301 - 309
  • [32] Thermal-ageing characteristics of dry-type transformer epoxy composite insulation
    Wang, Yongqiang
    Feng, Changhui
    Fei, Ruoyu
    Luo, Yu
    HIGH PERFORMANCE POLYMERS, 2020, 32 (07) : 741 - 752
  • [33] Thermal-aging characteristics of epoxy/glass fiber composite materials for dry-type air-core reactors
    Bian, Bo
    Xia, Guowei
    Li, Jingwei
    Shao, Shuai
    Duan, Qijun
    Xie, Qing
    POLYMER COMPOSITES, 2021, 42 (08) : 3773 - 3785
  • [34] SPECIFYING DRY-TYPE DISTRIBUTION TRANSFORMERS FOR SOLID-STATE APPLICATIONS
    KERSZENBAUM, I
    MAZUR, A
    MISTRY, M
    FRANK, J
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1991, 27 (01) : 173 - 178
  • [35] Analysis of Temperature Distribution in Cast-resin Dry-type Transformers
    Ebrahim Rahimpour
    Davood Azizian
    Electrical Engineering, 2007, 89 : 301 - 309
  • [36] Dry-type transformers: Specification, installation, and operational impacts in a marine environment
    Equisales Associates Inc., Houston, TX 77047, United States
    不详
    不详
    IEEE Ind Appl Mag, 2013, 5 (68-75):
  • [37] Investigation on Vibration Characteristics of Amorphous Metal Alloy Core Dry-type Distribution Transformer
    Kammeugue Noubissi Romaric
    Daosheng Liu
    Boxue Du
    CES Transactions on Electrical Machines and Systems, 2022, 6 (03) : 324 - 331
  • [38] A comparison of liquid-filled and dry-type transformers for industrial applications
    Dooley, PK
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (01) : 222 - 226
  • [39] A comparison of liquid-filled and dry-type transformers for industrial applications
    Dooley, PK
    CONFERENCE RECORD OF 1997 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 1997, : 108 - 112
  • [40] Specifying dry-type distribution transformers for solid-state applications
    Kerszenbaum, Isadoro
    Mazur, Alexander
    Mistry, Mahendra
    Frank, Jerome
    IEEE Transactions on Industry Applications, 1991, 27 (1 pt 1) : 173 - 178