Influence of core window height on thermal characteristics of dry-type transformers

被引:0
|
作者
Dawood, Kamran [1 ]
Kul, Seda [2 ]
机构
[1] Astor Enerji, Dept Res & Dev, Ankara, Turkiye
[2] Karamanoglu Mehmetbey Univ, Elect & Elect Engn Dept, Karaman, Turkiye
关键词
Core window; Dry-type transformer; Finite element analysis; Thermal analysis; Power transformer; TEMPERATURE; PERFORMANCE; EFFICIENCY; ONAN;
D O I
10.1016/j.csite.2025.105746
中图分类号
O414.1 [热力学];
学科分类号
摘要
Elevated temperatures in transformer windings and cores pose a significant risk of damage to power transformers. The objective of this work is to analyze the influence of core window dimensions on the thermal efficiency of power transformers. Analytical approaches are limited in their ability to consider the impact of core window dimensions on the transformer's thermal behavior. Conversely, experimental methods are both expensive and time-consuming. To overcome these constraints, this work assesses and optimizes the temperature distribution in dry-type power transformers using finite element models, specifically examining the impact of the core window. The thermal model treats core and winding losses as sources of heat generation. Four different transformers, with varying heights of the transformer core window, have been modeled to assess the impact of window height on the thermal conditions of the transformers. The simulation findings indicate that variations in core window height have a significant impact on the transformer's thermal properties. By comparing the model's predictions of short-circuit impedance with experimental data, this study demonstrates the model's capability to reliably estimate parameters influenced by core window variations, thereby validating its usefulness.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] DRY-TYPE TRANSFORMERS
    Wimmer, Jeffrey
    Tanner, M. R.
    Nunn, Tommy
    Kern, Joel
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2013, 19 (05) : 68 - 75
  • [2] THERMAL CONSIDERATIONS IN SPECIFYING DRY-TYPE TRANSFORMERS
    PIERCE, LW
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (04) : 1090 - 1098
  • [3] Thermal analysis of cast-resin dry-type transformers
    Eslamian, M.
    Vahidi, B.
    Eslamian, A.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) : 2479 - 2488
  • [4] Research on thermal aging characteristics of silicone rubber composite materials for dry-type distribution transformers
    Li, Woyang
    Zhou, Lijun
    Qian, Yunyun
    Lei, Qian
    Xia, Yingyi
    Wang, Dongyang
    E-POLYMERS, 2025, 25 (01)
  • [5] Thermal modeling of disc-type winding for ventilated dry-type transformers
    Lee, Moonhee
    Abdullah, Hussein A.
    Jofriet, Jan C.
    Patel, Dhiru
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (01) : 121 - 129
  • [6] Enhanced thermal modeling of three-phase dry-type transformers
    Americo, Jonatas P.
    Leite, Jean V.
    Mazzola, Cristian F.
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 58
  • [7] Air temperature effect on thermal models for ventilated dry-type transformers
    Lee, Moonhee
    Abdullah, Hussein A.
    Jofriet, Jan C.
    Patel, Dhiru
    Fahrioglu, Murat
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (03) : 783 - 789
  • [8] A Review of Thermal and Electrical Designs for Dry-type Transformers and Future Perspectives
    Xu, Hang
    Matharage, Shanika
    Wang, Zhongdong
    Squire, Darron
    Syzwala, Henry
    Fazakarley, Mark
    2024 IEEE ELECTRICAL INSULATION CONFERENCE, EIC 2024, 2024, : 380 - 383
  • [9] Partial discharge localization on dry-type transformers
    Szczechowski, Janusz
    Siodla, Krzysztof
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [10] Power factor testing dry-type transformers
    White, JR