Parallel MRI based on combination of nonlinear GRAPPA and SENSE

被引:0
|
作者
机构
[1] Jiang, Ming-Feng
[2] Zhu, Li-Tao
[3] Wang, Ya-Ming
[4] Xia, Ling
[5] Gong, Ying-Lan
来源
Jiang, Ming-Feng | 1865年 / Zhejiang University卷 / 48期
关键词
Acceleration rates - Hybrid techniques - NLGRAPPA-SENSE - Nonlinear GRAPPA - Parallel magnetic resonance imaging(pMRI) - Reconstruction accuracy - Sensitivity encoding - Sensitivity map;
D O I
10.3785/j.issn.1008-973X.2014.10.022
中图分类号
学科分类号
摘要
The nonlinear GRAPPA method was applied to estimate the undersampled K-space data in order to overcome the inaccuracy of sensitivity map of each coil calculated by zero-padding method. Then the accurate sensitivity map of each coil was calculated. The sensitivity encoding (SENSE) method was adopted to reconstruct the MR image from the under-sampled K-space data based on the accurate sensitivity map. The proposed hybrid technique was tested on MR brain image reconstructions at various acceleration rates. Experimental results show that the proposed method can achieve significant improvements in reconstruction accuracy when compared with the nonlinear GRAPPA and SENSE methods, with lower artificial power (AP) and higher signal to noise ratio (SNR). ©, 2014, Zhejiang University. All right reserved.
引用
收藏
相关论文
共 50 条
  • [31] A nonlinear regularization strategy for GRAPPA calibration
    Bydder, Mark
    Jung, Youngkyoo
    MAGNETIC RESONANCE IMAGING, 2009, 27 (01) : 137 - 141
  • [32] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [33] Variation of noise in multi-run functional MRI using generalized autocalibrating partially parallel acquisition (GRAPPA)
    Cheng, Hu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (02) : 462 - 470
  • [34] The Effect of Reconstruction and Acquisition Parameters for GRAPPA-Based Parallel Imaging on the Image Quality
    Bauer, S.
    Markl, M.
    Honal, M.
    Jung, B. A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 402 - 409
  • [35] REPRESENTATION OF GUNN DIODES BY PARALLEL COMBINATION OF NONLINEAR CONDUCTANCE AND NONLINEAR CAPACITANCE
    MIZUSHINA, S
    TAKAO, I
    PROCEEDINGS OF THE IEEE, 1973, 61 (01) : 137 - 138
  • [36] A comparison of fast MRI of hips with and without parallel imaging using SENSE
    Ryan, M
    Cunningham, P
    Cantwell, C
    Brennan, D
    Eustace, S
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (928): : 299 - 302
  • [37] 并行磁共振成像GRAPPA-SENSE技术
    王达
    包尚联
    中国医学影像技术, 2011, 27 (08) : 1688 - 1693
  • [38] Performance Analysis of 2-D GRAPPA and Partial Fourier GRAPPA for 3-D MRI
    Shan He
    Guoxi Xie
    Yiu-Cho Chung
    Yu Ding
    Xin Liu
    Bensheng Qiu
    Applied Magnetic Resonance, 2013, 44 : 1199 - 1212
  • [39] Iterative GRAPPA (iGRAPPA) for improved parallel imaging reconstruction
    Zhao, Tiejun
    Hu, Xiaoping
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 903 - 907
  • [40] Performance Analysis of 2-D GRAPPA and Partial Fourier GRAPPA for 3-D MRI
    He, Shan
    Xie, Guoxi
    Chung, Yiu-Cho
    Ding, Yu
    Liu, Xin
    Qiu, Bensheng
    APPLIED MAGNETIC RESONANCE, 2013, 44 (10) : 1199 - 1212