First in-vivo magic angle directional imaging using dedicated low-field MRI

被引:0
|
作者
Ristic, Mihailo [1 ]
Chappell, Karyn E. [1 ]
Lanz, Harry [1 ]
McGinley, John [1 ]
Gupte, Chinmay [2 ]
Amiras, Dimitris [3 ]
机构
[1] Imperial Coll London, Dept Mech Engn, Fac Engn, London, England
[2] Imperial Coll London, Dept Surg & Canc, Fac Med, London, England
[3] Imperial Coll NHS Healthcare Trust, Dept Radiol, London, England
基金
英国惠康基金;
关键词
collagen; magic angle effect; musculoskeletal imaging; ARTICULAR-CARTILAGE; MAGNETIC-RESONANCE; COLLAGEN; RELAXATION; ANISOTROPY; MAXIMIZATION; ORIENTATION; TENDONS; WATER; T-2;
D O I
10.1002/mrm.30332
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To report the first in-vivo results from exploiting the magic angle effect, using a dedicated low-field MRI scanner that can be rotated about two axes. The magic angle directional imaging (MADI) method is used to depict collagen microstructures with 3D collagen tractography of knee ligaments and the meniscus. Methods: A novel low-field MRI system was developed, based on a transverse field open magnet, where the magnet can be rotated about two orthogonal axes. Sets of volume scans at various orientations were obtained in healthy volunteers. The experiments focused on the anterior cruciate ligament (ACL) and the meniscus of the knee. The images were co-registered, anatomical regions of interest (ROIs) were selected and the collagen fiber orientations in each voxel were estimated from the observed image intensity variations. The 3D collagen tractography was superimposed on conventional volume images. Results: The MADI method was successfully employed for the first time producing in-vivo results comparable to those previously reported for excised animal specimens using conventional MRI. Tractography plots were generated for the ACL and the menisci. These results are consistent with the known microstructure of collagen fibers in these tissues. Conclusion: Images obtained using low-field MRI with 1mm(3) resolution were of sufficient quality for the MADI method, which was shown to produce high quality in-vivo information of collagen microstructures. This was achieved using a cost effective and sustainable low-field magnet making the technique potentially accessible and scalable, potentially changing the way we image injuries or disease in joints.
引用
收藏
页码:1077 / 1089
页数:13
相关论文
共 50 条
  • [21] Imaging of the lung using low-field magnetic resonance imaging
    Hinsen, Maximilian
    Heiss, Rafael
    Nagel, Armin M.
    Levy, Simon
    Uder, Michael
    Bickelhaupt, Sebastian
    May, Matthias S.
    ZEITSCHRIFT FUR PNEUMOLOGIE, 2024, : 29 - 37
  • [22] Imaging of the lung using low-field magnetic resonance imaging
    Hinsen, Maximilian
    Heiss, Rafael
    Nagel, Armin M.
    Levy, Simon
    Uder, Michael
    Bickelhaupt, Sebastian
    May, Matthias S.
    RADIOLOGE, 2022, 62 (05): : 418 - 428
  • [23] SPECT low-field MRI system for small-animal imaging
    Goetz, Christian
    Breton, Elodie
    Choquet, Philippe
    Israel-Jost, Vincent
    Constantinesco, Andre
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (01) : 88 - 93
  • [24] COMBINATION OF BIOMARKERS AND BONE IMAGING MARKERS FROM LOW-FIELD MRI
    Granlund, R. B.
    Byrjalsen, I.
    Karsdal, M. A.
    Dam, E. B.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S56 - S57
  • [25] Detection of stroke by portable, low-field MRI: A milestone in medical imaging
    Basser, Peter
    SCIENCE ADVANCES, 2022, 8 (16)
  • [26] Magic-angle spinning solid-state multinuclear NMR on low-field instrumentation
    Sorensen, Morten K.
    Bakharev, Oleg
    Jensen, Ole
    Jakobsen, Hans J.
    Skibsted, Jorgen
    Nielsen, Niels Chr.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 238 : 20 - 25
  • [27] CHARACTERIZATION OF THE MAGIC ANGLE EFFECT IN THE EQUINE DEEP DIGITAL FLEXOR TENDON USING A LOW-FIELD MAGNETIC RESONANCE SYSTEM
    Spriet, Mathieu
    McKnight, Alexia
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (01) : 32 - 36
  • [28] GATED CARDIAC IMAGING USING LOW-FIELD NMR
    NORRIS, DG
    HUTCHISON, JMS
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (07): : 779 - 787
  • [29] MR imaging evaluation of inflammatory arthritis in the wrist using a low-field dedicated extremity system (Artoscan(TM))
    Gindele, A
    Peterfy, C
    Hottya, G
    Hackl, F
    Uffmann, M
    Lang, P
    Otte, M
    Dion, E
    Genant, HK
    ARTHRITIS AND RHEUMATISM, 1996, 39 (09): : 441 - 441
  • [30] Low-field dedicated magnetic resonance imaging: a potential tool for assisting perinatal autopsy
    Langer, B
    Choquet, P
    Ravier, S
    Gasser, B
    Schlaeder, G
    Constantinesco, A
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 12 (04) : 271 - 275