Field Measurement and Numerical Simulation of Sound Insulation Characteristics of Buildings Along Elevated Urban Rail Lines

被引:0
|
作者
Wang, Teng [1 ,2 ]
He, Wei [3 ]
Wang, Dongyang [1 ,2 ]
Chen, Jialiang [1 ,2 ,4 ]
机构
[1] Beijing Oriental Yuhong Waterproof Technol Co Ltd, Beijing 101111, Peoples R China
[2] Beiijao Zane Rail Technol Beijing Co Ltd, Beijing 101111, Peoples R China
[3] China Univ Geosci Wuhan, Fac Engn, Wuhan 430074, Peoples R China
[4] Tsinghua Univ, Sch Civil Engn, Beijing 100084, Peoples R China
关键词
elevated urban rail transit; sound insulation characteristics; wall-windows assembly model; field measurement; finite element analysis;
D O I
10.3390/buildings14123799
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The noise pollution issue along elevated urban rail transit lines has attracted considerable attention; however, research on the sound insulation characteristics of buildings during operational train noise remains limited. In this study, a field testing campaign was conducted in a building featuring facades constructed from aerated concrete blocks embedded with single-layer glass sliding windows along an elevated rail transit line. The sound insulation characteristics of the building were obtained based on measured data. By neglecting the influence of lateral sound transmission, a window-wall assembly model was proposed for simulating the building's sound insulation capability. To ensure the accuracy of the prediction results, initial simulations were first performed on individual elements and compared against the experimental sound insulation curves to identify key parameters. Subsequently, simulations of the window-wall assembly model were carried out and compared with test data to determine the acoustic boundary treatment. The results showed that the amount of sound insulation measured in the buildings ranged from 11.16 dB (A) to 19.85 dB (A) during train passage, exhibiting a notable dip in sound insulation within the frequency range of 80 Hz to 100 Hz. Conversely, the predicted sound insulation of 26.38 dB was much higher, also showing a significant dip at around 100 Hz. The simulated values aligned closely with the measured values below 500 Hz; however, discrepancies were observed in mid-to-high frequency ranges above this threshold. To this end, further simulations were performed on a window-wall assembly model incorporating air gaps to take into account air leakage effects. The results indicated that the presence of air gaps considerably diminished high-frequency sound insulation; when accounting for window air leakage effects, the simulated results approached closer alignment with the measured ones.
引用
收藏
页数:18
相关论文
共 21 条
  • [21] Field measurement and numerical simulation of combined solar heating operation modes for domestic buildings based on the Qinghai-Tibetan plateau case
    Liu, Zhijian
    Wu, Di
    Yu, Hancheng
    Ma, Wensheng
    Jin, Guangya
    ENERGY AND BUILDINGS, 2018, 167 : 312 - 321