Three phase short circuit fault transient analysis of wind farm installed with DFIG wind turbine system

被引:0
|
作者
Department of Thermal Engineering, Tsinghua University, Beijing 100084, China [1 ]
不详 [2 ]
机构
来源
Kongzhi Lilun Yu Yingyong/Control Theory and Applications | 2008年 / 25卷 / 01期
关键词
Dynamic models - MATLAB - Transient analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Three phase short circuit fault transient analysis of wind farm installed with DFIG wind turbine system deals with the impact between the wind farm and electrical network. First, based on theoretical analysis, a dynamic model of wind turbine system and power grid were built. Then, applying Matlab/Simulink to parameters of the system, the simulation model of wind farm was programmed. Finally, with the digital simulation and analysis, the transient characteristics of key parameters of the wind farm and wind turbine unit were discussed. The built model and simulation results provided the theoretical basis of research of the impact between the wind farm and the electrical network.
引用
收藏
页码:141 / 144
相关论文
共 50 条
  • [41] Voltage Transient Study of Wind Farm under Power System Fault
    Zhang, Xin-yan
    Wang, Wei-qing
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 169 - +
  • [42] Limiting the Fault Current of a DFIG Wind Turbine System Using Resistive Ladder Network
    Thapaliya, Sudeep
    Rahim, A. H. M. A.
    2022 INTERNATIONAL CONFERENCE ON ENERGY AND POWER ENGINEERING, ICEPE, 2022,
  • [43] Oscillatory Stability and Eigenvalue Sensitivity Analysis of A DFIG Wind Turbine System
    Yang, Lihui
    Xu, Zhao
    Ostergaard, Jacob
    Dong, Zhao Yang
    Wong, Kit Po
    Ma, Xikui
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 328 - 339
  • [44] Enhancing DFIG wind turbine during three-phase fault using parallel interleaved converters and dynamic resistor
    Okedu, Kenneth E.
    IET RENEWABLE POWER GENERATION, 2016, 10 (08) : 1211 - 1219
  • [45] Short Circuit Behavior of Wind Turbine Generators
    Walling, Reigh A.
    Reichard, Michael L.
    2009 62ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2009, : 492 - 502
  • [46] Fault Diagnosis of Wind Turbine Gearboxes Based on DFIG Stator Current Envelope Analysis
    Cheng, Fangzhou
    Qu, Liyan
    Qiao, Wei
    Wei, Chun
    Hao, Liwei
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2019, 10 (03) : 1044 - 1053
  • [47] Diagnosis of Rotor Winding Inter -turn Short Circuit Fault in Wind Turbine Based on DFIG using Hybrid TSA/DWT Approach
    Sabir, Hamza
    Ouassaid, Mohammed
    Ngote, Nabil
    2018 6TH INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2018, : 404 - 409
  • [48] Investigation of a converter fault for a DFIG wind turbine and analysis of the resulting gearbox component loads
    Roeder, Julian
    Jacobs, Georg
    Bosse, Dennis
    Herzog, Fabian
    Graf, Lukas
    WINDEUROPE ANNUAL EVENT 2022, 2022, 2257
  • [49] Impedance Modeling of DFIG-Wind Turbine System
    Liao, Xiaozhong
    Sun, Hang
    Li, Zhen
    Wong, Siu-Chung
    Tian, Li
    Wang, Miaoyuan
    Liu, Xiangdong
    2015 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2015, : 245 - 248
  • [50] The system of nonlinear adaptive control for wind turbine with DFIG
    Medvedev, Mikhail
    Mazalov, Andrey
    EAI Endorsed Transactions on Energy Web, 2014, 1 (02) : 1 - 9