Pulse-Echo Ultrasound for Quantitative Measurements of Two Uncorrelated Elastic Parameters

被引:1
|
作者
Hansen, Rune [1 ,2 ]
Ervik, Oyvind [2 ,3 ]
Amini, Naseh [4 ]
Solberg, Stian [4 ]
Berg, Sigrid [1 ]
Ayyalasomayajula, Venkat [5 ]
Skallerud, Bjorn [5 ]
Leira, Hakon Olav [2 ,6 ]
Sorger, Hanne [2 ,3 ]
Avdal, Jorgen [1 ]
机构
[1] SINTEF Digital, Dept Hlth Res, Postboks 4760 Torgarden, N-7465 Trondheim, Norway
[2] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, Trondheim, Norway
[3] Levanger Hosp, Nord Trondelag Hosp Trust, Clin Med, Levanger, Norway
[4] SURF Technol, Trondheim, Norway
[5] Norwegian Univ Sci & Technol, Dept Struct Engn, Trondheim, Norway
[6] St Olavs Hosp, Dept Thorac Med, Trondheim, Norway
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2025年 / 51卷 / 01期
关键词
Ultrasound; Elastic properties; Nonlinear acoustics; Dual-frequency; Shear waves; ACOUSTIC NONLINEARITY; SHEAR-WAVE; BIOMEDICAL FREQUENCIES; REFLECTION MODE; SOUND SPEED; TISSUE; ELASTOGRAPHY; CONTRAST; SINGLE; STRAIN;
D O I
10.1016/j.ultrasmedbio.2024.08.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: This paper describes the relationship between elastic tissue properties and strain and presents an initial investigation of pulse-echo ultrasound to measure two uncorrelated elastic parameters in tissue-mimicking phantoms. The two elastic parameters are the shear modulus, related to deformation of shape, and what we in the paper define as the nonlinear compressibility, related to deformation of volume. Methods: We prepared tissue-mimicking phantoms containing lesions of variable shear modulus and variable nonlinear compressibility. An in-house framework for shear wave imaging was developed using ultrasound radiation force at 4.5 MHz to induce shear waves and plane wave imaging with pulses in a frequency band centered around 12.5 MHz to track the shear waves. For measurements of nonlinear compressibility, co-propagating dual-frequency pulse complexes at 0.7 MHz and 14 MHz were applied. Algorithms were implemented on a Verasonics Vantage ultrasound scanner and a custom-made multi-frequency ultrasound transducer was used. Mechanical indentation measurements were performed to validate ultrasound measurements of the shear modulus. For the nonlinear compressibility, ultrasound measurements were compared to results derived from the literature. Results: We found good agreement in elasticity results from ultrasound measurements and mechanical indentation as well as when comparing with results derived from the literature. Conclusion: Results of the current investigation were promising. We plan patient studies involving thyroid lesions and liver steatosis to explore whether measurements of elastic parameters related both to shape deformation and volume deformation are useful in clinical practice.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 50 条
  • [31] Monitoring mineral slurry flow using pulse-echo ultrasound
    Stener, Jan F.
    Carlson, Johan E.
    Sand, Anders
    Palsson, Bertil I.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2016, 50 : 135 - 146
  • [32] Comparison of Pulse-Echo Methods for Measuring Ultrasound Attenuation in the Liver
    Kim, H.
    Musack, R.
    Varghese, T.
    Kliewer, M.
    Jiang, J.
    Hall, T.
    Zagzebski, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [33] COMPARISON OF COMPUTED ULTRASOUND TOMOGRAPHY AND PULSE-ECHO IMAGING IN THE HEAD
    DINES, KA
    FRY, FJ
    PATRICK, JT
    GILMOR, RL
    RADIOLOGY, 1982, 144 (04) : 949 - 949
  • [34] FRACTURE DISCRIMINATION USING A NOVEL PULSE-ECHO ULTRASOUND DEVICE
    Karjalainen, Janne
    Riekkinen, Ossi
    Schousboe, John
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 : 637 - 637
  • [35] A LOW-COST GATE FOR ULTRASOUND PULSE-ECHO STUDIES
    LANGRILL, LN
    GOLDSTEIN, A
    MEDICAL PHYSICS, 1980, 7 (06) : 710 - 711
  • [36] Noninvasive temperature imaging using diagnostic pulse-echo ultrasound
    Ebbini, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 2528 - 2528
  • [37] PRESCREENING FOR LOW HIP BMD BY USING PULSE-ECHO ULTRASOUND
    van den Berg, P.
    Schweitzer, D. H.
    OSTEOPOROSIS INTERNATIONAL, 2017, 28 : S531 - S531
  • [38] Defects Detection Using a Smart Ultrasound Pulse-Echo Technique
    Lee, Wan Jae
    Chang, Wenji Victor
    Yang, Wei
    Kim, Byungsoo
    POLYMER COMPOSITES, 2010, 31 (06) : 1105 - 1112
  • [39] Development of Polygonal Buffer Rods for Ultrasonic Pulse-Echo Measurements
    Foudzi, F. M.
    Ihara, I.
    3RD INTERNATIONAL SYMPOSIUM ON LASER ULTRASONICS AND ADVANCED SENSING, 2014, 520
  • [40] Scatterer size estimation in pulse-echo ultrasound using focused sources: Calibration measurements and phantom experiments
    Bigelow, TA
    O'Brien, WD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (01): : 594 - 602