Safety distance for live working on ±400 kV DC transmission line interconnecting Qinghai power grid with tibet power grid

被引:0
|
作者
Ding, Yujian [1 ]
Sun, Hui [2 ]
Li, Jun [3 ]
Zhou, Jun [1 ]
Li, Qingfeng [1 ]
Bai, Wei [3 ]
Ma, Le [3 ]
机构
[1] China Electric Power Research Institute, Haidian District, Beijing,100192, China
[2] School of Electrical and Electronic Engineering, North China Electric Power University, Baoding,Hebei,071003, China
[3] Province Maintenance Company of State Grid Qinghai Electric Power Corporation, Xining,Qinghai Province,810000, China
来源
关键词
D O I
10.13335/j.1000-3673.pst.2014.10.043
中图分类号
学科分类号
摘要
引用
收藏
页码:2894 / 2899
相关论文
共 50 条
  • [21] Research on safety protection for live working on ±800kV DC transmission line with AC and DC multi-circuit transmission lines
    Xie, Yan
    Xiang, Tao
    Li, Mu
    3RD INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2017, 61
  • [22] Research on Safety Protection for Live Working on ±500kV DC Transmission Line with AC and DC Multi-circuit Transmission Lines
    Xie, Yan
    Li, Mu
    Zheng, Changzheng
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS, MECHATRONICS AND CIVIL ENGINEERING (ICAMMCE 2017), 2017, 121 : 53 - 56
  • [23] Calculation of geomagnetically induced currents in the 400 kV power grid in southern Sweden
    Wik, M.
    Viljanen, A.
    Pirjola, R.
    Pulkkinen, A.
    Wintoft, P.
    Lundstedt, H.
    SPACE WEATHER-THE INTERNATIONAL JOURNAL OF RESEARCH AND APPLICATIONS, 2008, 6 (07):
  • [24] Modeling of a 400 kV Transmission Line of Bangladesh Power System Network
    Emrose, Md Tanvir
    Chowdhury, A. H.
    Hasan, S. M. Mehedi
    2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1134 - 1139
  • [25] Power-Line Communications: Smart Grid, Transmission, and Propagation
    Anatory, Justinian
    Ribeiro, Moises V.
    Tonello, Andrea M.
    Zeddam, Ahmed
    JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2013, 2013
  • [26] Shielding Failure Risk Assessment for 500kV Typical Transmission Line in Anhui Power Grid
    Zhao, Chun
    Zhen, Shiling
    Xie, Yaoheng
    Gu, Shanqiang
    Ding, Li
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 725 - +
  • [27] Study of increasing 500kV transmission line capacity of East China electric power grid
    Zhang, QP
    Qian, ZY
    Proceedings of the World Engineers' Convention 2004, Vol F-B, Power and Energy, 2004, : 376 - 380
  • [28] FIRST 500-KV AC TRANSMISSION-LINE DESIGNS FOR BONNEVILLE POWER ADMINISTEATIONS GRID
    OSIPOVICH, AA
    POLAND, MG
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (01): : 28 - +
  • [29] Analysis of live working on Yun-Guang ±800 kV DC transmission line
    Xiao, Yong
    Fan, Ling-Meng
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (09): : 2206 - 2211
  • [30] Analysis on blocking of Qinghai-Tibet DC system caused by transformer energizing in northwest China 750 kV grid
    Zhou, Peipeng
    Xiang, Zutao
    Du, Ning
    Ban, Liangeng
    Xie, Guoping
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (10): : 129 - 133