Safety distance for live working on ±400 kV DC transmission line interconnecting Qinghai power grid with tibet power grid

被引:0
|
作者
Ding, Yujian [1 ]
Sun, Hui [2 ]
Li, Jun [3 ]
Zhou, Jun [1 ]
Li, Qingfeng [1 ]
Bai, Wei [3 ]
Ma, Le [3 ]
机构
[1] China Electric Power Research Institute, Haidian District, Beijing,100192, China
[2] School of Electrical and Electronic Engineering, North China Electric Power University, Baoding,Hebei,071003, China
[3] Province Maintenance Company of State Grid Qinghai Electric Power Corporation, Xining,Qinghai Province,810000, China
来源
关键词
D O I
10.13335/j.1000-3673.pst.2014.10.043
中图分类号
学科分类号
摘要
引用
收藏
页码:2894 / 2899
相关论文
共 50 条
  • [1] Digital/analog hybrid simulation of Tibet grid integrated with ±400 kV DC transmission line from Qinghai to Tibet
    Guo, Hu
    Xie, Guoping
    Zhu, Yiying
    Chen, Lingfang
    Dianwang Jishu/Power System Technology, 2013, 37 (02): : 455 - 459
  • [2] Voltage and reactive power control of the Tibet regional power grid after Qinghai-Tibet DC connection
    Tang, Xiaojun
    Liu, Dongran
    Chen, Qiyu
    Ma, Min
    Ma, Shiying
    Cuo, Mu
    Cidan, Yuzhen
    Chen, Yun
    Dianwang Jishu/Power System Technology, 2010, 34 (09): : 94 - 99
  • [3] Development and Application of ±500 kV DC Transmission Line Arrester in China Power Grid
    Gu, Shanqiang
    Wan, Shuai
    Wang, Jian
    Chen, Jiahong
    Li, Tao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (01) : 209 - 217
  • [4] Criteria for Applying of Live Working Technologies in Romanian Transmission Power Grid
    Morar, D.
    Rodean, I.
    Oltean, M.
    Brabete, L.
    2014 11TH INTERNATIONAL CONFERENCE ON LIVE MAINTENANCE (ICOLIM), 2014,
  • [5] Lightning protection level for 500 kV high altitude transmission lines in the Tibet power grid and Sichuan power grid interconnection project
    Chen X.
    Xia C.
    Yin Y.
    Wang C.
    Zhang Y.
    Liang M.
    Gaodianya Jishu/High Voltage Engineering, 2016, 42 (05): : 1535 - 1540
  • [6] Bird-related fault analysis and prevention measures of ±400 kV Qinghai-Tibet DC transmission line
    Ding, Yujian
    Zhou, Jun
    Li, Changkan
    Liu, Guilin
    Wang, Huapeng
    Yao, Xiuyuan
    Wang, Xi
    Wang, Shenghui
    ENERGY REPORTS, 2021, 7 : 426 - 433
  • [7] Fault Analysis and Treatment of Bird Dropping Flashover on ±400kV Qinghai-Tibet DC Transmission Line
    Zhou J.
    Zhang X.
    Wang S.
    Lü J.
    Wang J.
    Peng B.
    Wang X.
    Ding Y.
    Wang X.
    Yang M.
    Gao Y.
    Wang B.
    Dianwang Jishu/Power System Technology, 2020, 44 (03): : 1168 - 1174
  • [8] Fault classification on transmission line of 10kV rural power grid
    Lv, Chunyu
    Zhang, Shuguang
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, 2016, 43 : 384 - 387
  • [9] Analysis on safety protective equipments for live working on ±800 kV UHV DC transmission line
    Hu, Yi
    Liu, Kai
    Hu, Jian-Xun
    Liu, Ting
    Xiao, Bin
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (10): : 2357 - 2361
  • [10] Investigation on ferroresonance due to power transformer energization in high voltage 400 kV transmission grid
    Polewaczyk, Mateusz
    Robak, Sylwester
    Szewczyk, Marcin
    ARCHIVES OF ELECTRICAL ENGINEERING, 2019, 68 (04) : 771 - 786