Total transfer capability assessment incorporating corrective controls for transient stability using TSCOPF

被引:0
|
作者
Hakim L. [1 ]
Kubokawa J. [2 ]
Yorino N. [1 ]
Zoka Y. [1 ,3 ]
Sasaki Y. [1 ]
机构
[1] Hiroshima University, Higashi-hiroshima 739-8527, 1-4-1, Kagamiyama
[2] Hiroshima Institute of Technology, Saeki-ku, Hiroshima 731-5143, 2-1-1, Miyake
[3] Graduate School of Engineering, Hiroshima University, Higashi-hiroshima 739-8527, 1-4-1, Kagamiyama
关键词
Corrective control; Total transfer capability; Transient stability constrained optimal power flow;
D O I
10.1541/ieejpes.130.399
中图分类号
学科分类号
摘要
Advancements have been made towards inclusion of both static and dynamic security into transfer capability calculation. However, to the authors' knowledge, work on considering corrective controls into the calculation has not been reported yet. Therefore, we propose a Total Transfer Capability (TTC) assessment considering transient stability corrective controls. The method is based on the Newton interior point method for nonlinear programming and transfer capability is approached as a maximization of power transfer with both static and transient stability constraints are incorporated into our Transient Stability Constrained Optimal Power Flow (TSCOPF) formulation. An interconnected power system is simulated to be subjected to a severe unbalanced 3-phase 4-line to ground fault and following the fault, generator and load are shed in a pre-defined sequence to mimic actual corrective controls. In a deregulated electricity market, both generator companies and large load customers are encouraged to actively participate in maintaining power system stability as corrective controls upon agreement of compensation for being shed following a disturbance. Implementation of this proposai on the actual power system operation should be carried out through combining it with the existing transient stabilization controller system. Utilization of these corrective controls results in increasing TTC as suggested in our numerical simulation. As Lagrange multipliers can also describe sensitivity of both inequality and equality constraints to the objective fonction, then selection of which generator or load to be shed can be carried out on the basis of values of Lagrange multipliers of its respective generator's rotor angle stability and active power balance equation. Hence, the proposal in this paper can be utilized by system operator to assess the maximum TTC for specific loads and network conditions. © 2010 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:399 / 406
页数:7
相关论文
共 50 条
  • [41] Transient stability assessment using artificial neural network
    Sanyal, KK
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, : 633 - 637
  • [42] Transient Stability Assessment using Gated Recurrent Unit
    Zhou, Yuhao
    Yang, Yude
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 560 - 564
  • [43] Transient stability assessment using artificial neural networks
    ElAmin, IM
    AlShams, AAM
    ELECTRIC POWER SYSTEMS RESEARCH, 1997, 40 (01) : 7 - 16
  • [44] Versatile and Robust Transient Stability Assessment via Instance Transfer Learning
    Meghdadi, Seyedali
    Tack, Guido
    Liebman, Ariel
    Langrene, Nicolas
    Bergmeir, Christoph
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [45] A Method for Power System Transient Stability Assessment Based on Transfer Learning
    Ren, Junyu
    Chen, Jinfu
    Li, Benyu
    Zhao, Ming
    Shi, Hengchu
    You, Hao
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [46] Incorporating dynamic security into market dispatch using accurate transient stability constraints
    Jayasekara, B.
    Annakkage, U. D.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 52 - +
  • [47] BC Hydro's Transmission Reliability Margin Assessment in Total Transfer Capability Calculations
    Li, Wenyuan
    Vaahedi, Ebrahim
    Lin, Zhenhua
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) : 4796 - 4802
  • [48] Reactive Power Control Method for Enhancing the Transient Stability Total Transfer Capability of Transmission Lines for a System with Large-Scale Renewable Energy Sources
    Zhang, Yuwei
    Liu, Wenying
    Wang, Fangyu
    Zhang, Yaoxiang
    Li, Yalou
    ENERGIES, 2020, 13 (12)
  • [49] A transient stability assessment method for power systems incorporating residual networks and BiGRU-attention
    Shan Cheng
    Qiping Xu
    Haidong Wang
    Zihao Yu
    Rui Wang
    Tao Ran
    Global Energy Interconnection, 2025, 8 (01) : 143 - 159
  • [50] Multi-task Transient Stability Assessment of Power System Incorporating Graph Embedding Algorithm
    Sun L.
    Peng J.
    Bai J.
    Chen X.
    Tian Y.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (02): : 83 - 91