Analysis of Tear Glucose Concentration with Electrospray Ionization Mass Spectrometry

被引:0
|
作者
Taormina, Christopher R. [1 ]
Baca, Justin T. [1 ]
Asher, Sanford A. [1 ]
Grabowski, Joseph J. [1 ]
Finegold, David N. [2 ]
机构
[1] Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, United States
[2] Department of Pediatrics, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States
关键词
We have developed a mass spectrometry-based method that allows one to accurately determine the glucose concentration of tear fluid. We used a 1 μL micro-capillary to collect tear fluid from the tear meniscus with minimal irritation of the eye. We analyzed the 1 μL volume of collected tear fluid with liquid-chromatography electrospray ionization mass spectrometry with the use of D-glucose-6,6-d2 as an internal standard. Repeated measurements and a recovery experiment on pooled, onion-induced tears showed that the analysis of the glucose in tears was precise (4% relative standard deviation) and provided 100% recovery. We found the tear glucose concentration of one fasting nondiabetic subject to be 13 to 51 μM while the onion-induced tear glucose concentration of a different nondiabetic subject to be 211 to 256 μM. © 2007 American Society for Mass Spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:332 / 336
相关论文
共 50 条
  • [31] HEMOGLOBIN ANALYSIS BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    WHITE, EL
    UHRIG, MS
    REED, EA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 63 - ANYL
  • [32] GEOPORPHYRIN ANALYSIS USING ELECTROSPRAY IONIZATION MASS-SPECTROMETRY
    VANBERKEL, GJ
    QUINONES, MA
    QUIRKE, JME
    ENERGY & FUELS, 1993, 7 (03) : 411 - 419
  • [33] Desorption electrospray ionization mass spectrometry for the analysis of pharmaceuticals and metabolites
    Kauppila, TJ
    Wiseman, JM
    Ketola, RA
    Kotiaho, T
    Cooks, RG
    Kostiainen, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (03) : 387 - 392
  • [34] Analysis of peptide synthesis products by electrospray ionization mass spectrometry
    Burdick, DJ
    Stults, JT
    SOLID-PHASE PEPTIDE SYNTHESIS, 1997, 289 : 499 - 519
  • [35] Analysis of black writing ink by electrospray ionization mass spectrometry
    Williams, Mary R.
    Moody, Chris
    Arceneaux, Lei-Ann
    Rinke, Caitlin
    White, Katie
    Sigman, Michael E.
    FORENSIC SCIENCE INTERNATIONAL, 2009, 191 (1-3) : 97 - 103
  • [36] Carbohydrate and steroid analysis by desorption electrospray ionization mass spectrometry
    Kauppila, Tiina J.
    Talaty, Nari
    Jackson, Ayanna U.
    Kotiaho, Tapio
    Kostiainen, Risto
    Cooks, R. Graham
    CHEMICAL COMMUNICATIONS, 2008, (23) : 2674 - 2676
  • [37] Analysis of hydrophobic proteins and peptides by electrospray ionization mass spectrometry
    Schaller, J
    Pellascio, BC
    Schlunegger, UP
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (04) : 418 - 426
  • [38] Effects of salt concentration on analyte response using electrospray ionization mass spectrometry
    Constantopoulos, TL
    Jackson, GS
    Enke, CG
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (07) : 625 - 634
  • [39] Effects of solvent parameters on the electrospray ionization tandem mass spectrometry response of glucose
    Thacker, Jonathan B.
    Schug, Kevin A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (15) : 1191 - 1198
  • [40] Targeted metabolomic analysis of Escherichia coli by desorption electrospray ionization and extractive electrospray ionization mass spectrometry
    Jackson, Ayanna U.
    Werner, Sean R.
    Talaty, Narl
    Song, Yishu
    Campbell, Karinna
    Cooks, R. Graham
    Morgan, John A.
    ANALYTICAL BIOCHEMISTRY, 2008, 375 (02) : 272 - 281