Analysis of Tear Glucose Concentration with Electrospray Ionization Mass Spectrometry

被引:0
|
作者
Taormina, Christopher R. [1 ]
Baca, Justin T. [1 ]
Asher, Sanford A. [1 ]
Grabowski, Joseph J. [1 ]
Finegold, David N. [2 ]
机构
[1] Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, United States
[2] Department of Pediatrics, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States
关键词
We have developed a mass spectrometry-based method that allows one to accurately determine the glucose concentration of tear fluid. We used a 1 μL micro-capillary to collect tear fluid from the tear meniscus with minimal irritation of the eye. We analyzed the 1 μL volume of collected tear fluid with liquid-chromatography electrospray ionization mass spectrometry with the use of D-glucose-6,6-d2 as an internal standard. Repeated measurements and a recovery experiment on pooled, onion-induced tears showed that the analysis of the glucose in tears was precise (4% relative standard deviation) and provided 100% recovery. We found the tear glucose concentration of one fasting nondiabetic subject to be 13 to 51 μM while the onion-induced tear glucose concentration of a different nondiabetic subject to be 211 to 256 μM. © 2007 American Society for Mass Spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:332 / 336
相关论文
共 50 条
  • [1] Analysis of tear glucose concentration with electrospray ionization mass spectrometry
    Taormina, Christopher R.
    Baca, Justin T.
    Asher, Sanford A.
    Grabowski, Joseph J.
    Finegold, David N.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (02) : 332 - 336
  • [2] Aluminum speciation of coagulants with low concentration: Analysis by electrospray ionization mass spectrometry
    Zhao, He
    Liu, Huijuan
    Qu, Jiuhui
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2011, 379 (1-3) : 43 - 50
  • [3] Analysis of metal species by using electrospray ionization mass spectrometry and capillary electrophoresis electrospray ionization mass spectrometry
    Schramel, O
    Michalke, B
    Kettrup, A
    JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) : 231 - 242
  • [4] Analysis of perchlorate in groundwater by electrospray ionization mass spectrometry/mass spectrometry
    Koester, CJ
    Beller, HR
    Halden, RU
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) : 1862 - 1864
  • [6] Electrospray ionization mass spectrometry
    Banks, JF
    Whitehouse, CM
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A, 1996, 270 : 486 - 519
  • [7] Electrospray Ionization for Mass Spectrometry
    不详
    LC GC NORTH AMERICA, 2012, 30 (02) : 182 - 182
  • [8] Analysis of rabbit tear proteins by high-pressure liquid chromatography/electrospray ionization mass spectrometry
    Zhou, L
    Beuerman, RW
    Barathi, A
    Tan, D
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (05) : 401 - 412
  • [9] Protein analysis by desorption electrospray ionization mass spectrometry
    Venter, Andre R.
    MASS SPECTROMETRY REVIEWS, 2024,
  • [10] Analysis of vegetable oil by electrospray ionization mass spectrometry
    Gao, Lin
    Yu, Jian-Er
    Zhu, Feng-Ying
    Wang, Fu
    Huadong Ligong Daxue Xuebao /Journal of East China University of Science and Technology, 2007, 33 (03): : 379 - 382