Heat transfer enhancement of PCM in the triple-pipe helical-coiled latent heat thermal energy storage unit and complete melting time correlation

被引:0
|
作者
Zhao, Chuang-Yao [1 ,2 ,6 ]
Jia, Chen-Yi [1 ,2 ]
Xu, Ling-Ling [1 ,2 ]
Zhang, Fang-Fang [3 ]
Qi, Di [1 ,2 ]
Song, Bing-Ye [1 ,2 ]
Liu, Qing [4 ]
Jiang, Jun-Min [5 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Minist Educ China, Int Joint Lab Low Carbon Built Environm, Beijing, Peoples R China
[3] Zhengzhou Univ Light Ind, Sch Energy & Power Engn, Zhengzhou 450001, Peoples R China
[4] Xian Univ Architecture & Technol, Sch Resources Engn, Xian 710055, Peoples R China
[5] Xian Univ Architecture & Technol, Sch Mech & Elect Engn, Xian, Peoples R China
[6] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal energy storage; Phase change material; Melting process; Triplex-pipe; Helical-coil; Dimensional analysis; PHASE-CHANGE MATERIAL; PERFORMANCE ANALYSIS; NATURAL-CONVECTION; WATER NANOFLUID; METAL FOAM; TUBE; EXCHANGER; SYSTEM; SHELL; SOLIDIFICATION;
D O I
10.1016/j.renene.2024.121528
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Secondary flows induced in helical-coiled pipes significantly enhance the thermal storage performance of latent heat thermal energy storage units. This paper presents a three-dimensional model of a triple-pipe helical-coiled system to investigate the melting characteristics of phase change material within it. A correlation for the complete melting time was developed based on the simulation results. The findings indicate that the thermal- hydraulic fields of the heat transfer fluids and phase change material deflect from the vertical central axis at cross-sections. The secondary flows within the inner pipe are more effective in enhancing melting than those in the outer pipe. Melting performance improves with increasing inner pipe diameter, coil diameter (from 100 mm to 160 mm), inclination angle, or heat transfer fluid temperature, or decreasing helical pitch. The inner pipe diameter, helical pitch and heat transfer fluid temperature exhibit more pronounced influences. An inner pipe diameter of 30 mm, a coil diameter of 160 mm, a helical pitch of 80 mm, an inclination angle of 90 degrees, a heat transfer fluid temperature of 360 K, and a heat transfer fluid Reynolds number of 2000, respectively produce a faster melting process. The developed correlation for the triple-pipe helical-coiled pipe thermal storage unit accurately predicts 96 % of the 45 data within +/- 11 %.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Influence of heat transfer fluid on thermal performance improvement of latent heat storage unit with helical fins
    He, Fan
    Li, Shanshan
    Zuo, Yaoguo
    Gao, Yanna
    Pang, Feng
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 49
  • [22] Performance evaluation of the multiple layer latent heat thermal energy storage unit combined with nanoparticle for heat transfer enhancement
    Zhang C.
    Wang N.
    Xu H.
    Luo Z.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2023, 42 (05): : 2332 - 2342
  • [23] Heat transfer enhancement in water when used as PCM in thermal energy storage
    Cabeza, LF
    Mehling, H
    Hiebler, S
    Ziegler, F
    APPLIED THERMAL ENGINEERING, 2002, 22 (10) : 1141 - 1151
  • [24] Experimental improvements of heat transfer in a latent heat thermal energy storage unit with embedded heat sources
    Lacroix, M
    Duong, T
    ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (08) : 703 - 716
  • [25] Heat transfer enhancement and performance study on latent heat thermal energy storage system using different configurations of spherical PCM balls
    Surya, A.
    Prakash, R.
    Nallusamy, N.
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [26] A systematic review of metal foam and heat pipe enhancement in Latent Heat Thermal Energy Storage system
    Varthani, A. Jaisatia
    Shasthri, S.
    Baljit, S.
    Kausalyah, V.
    JOURNAL OF ENERGY STORAGE, 2022, 56
  • [27] Heat Transfer Properties of a Latent Thermal Storage Unit with Flat Microheat Pipe Arrays
    Liu, J.
    Diao, Y. H.
    Zhao, Y. H.
    Li, F. F.
    Zhu, T. T.
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (05)
  • [28] HEAT TRANSFER ANALYSIS OF A LOW-TEMPERATURE HEAT PIPE-ASSISTED LATENT HEAT THERMAL ENERGY STORAGE SYSTEM WITH NANO-ENHANCED PCM
    Mahdavi, Mahboobe
    Tiari, Saeed
    Pawar, Vivek
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 6B, 2019,
  • [29] Development of correlation for melting time of phase change material in latent heat storage unit
    Manish, Rathod K.
    Jyotirmay, Banerjee
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 2125 - 2130
  • [30] Heat transfer enhancement of latent heat thermal energy storage with longitudinal stepped fins inside heat transfer fluid
    Lu, Yongwen
    Chi, Bowen
    Zuo, Hongyang
    Xu, Huaqian
    Zeng, Kuo
    Gao, Junjie
    Yang, Haiping
    Chen, Hanping
    JOURNAL OF ENERGY STORAGE, 2024, 87