Comprehensive study of a geothermal multi-generation system composed of absorption refrigeration, vapor compression refrigeration, and a fan coil unit to sustain sport facilities

被引:0
|
作者
Wang, Xu [1 ]
Wang, Tianpeng [2 ]
Khani, Ahmad [3 ]
Su, Zhanguo [1 ,3 ]
机构
[1] Huainan Normal Univ, Fac Phys Educ, Huainan 232038, Anhui, Peoples R China
[2] Huainan Normal Univ, Fac Law, Huainan 232038, Anhui, Peoples R China
[3] Krirk Univ, Int Coll, Bangkok 10220, Thailand
关键词
Geothermal system; Thermodynamic analysis; Exergoeconomic analysis; Single-effect absorption refrigeration; Fan coil unit; Sustainable sport facilities; DEHUMIDIFICATION SYSTEMS; PERFORMANCE ASSESSMENT; TRIGENERATION SYSTEM; WATER PRODUCTION; POWER-SYSTEM; ENERGY; HYBRID; OPTIMIZATION; HYDROGEN; WIND;
D O I
10.1016/j.renene.2024.122289
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Over the past years, considerable focus has been placed on advancing sustainable energy solutions for buildings, aimed at reducing carbon emissions, enhancing energy performance, and fostering a higher scope of eco-friendly behavior concerning working and residential environments. Specifically, sport facilities raise a need for thorough attention due to relatively high requisites in terms of volume and diversity. This paper delved into thermodynamic and exergoeconomic investigation for a system that combines cascade absorption refrigeration system with a vapor compression refrigeration system, powered by geothermal renewable reservoir of energy. This innovative system served the purpose of generating four distinct outputs: electricity, cooling, potable water, and heating, which are the main requisites of an independent sport facility. Key system performance parameters, such as net power output, COP, SUCP, energy efficiency, and exergy efficiency, in its BM, are measured at 69.74 kW, 0.35, 55.9$/GJ, 48.1 %, and 21.44 %, respectively. This research explored the impact of various factors, including flow rates and pressure from the geothermal source, condenser temperature, the ratio of fresh air, temperatures at the evaporator-condenser interface of the absorption refrigeration section, and the vapor compression refrigeration system's evaporator temperature. Furthermore, the analysis revealed that the highest exergy destruction occurs during geofluid reinjection, accounting for approximately 53 % of the total exergy destruction. All calculations were conducted using the EES, accounting for the outdoor weather conditions specific to the summer climate in Shanghai.
引用
收藏
页数:16
相关论文
共 14 条
  • [11] Advanced Cascaded Recompression Absorption System Equipped with Ejector and Vapor-Injection Enhanced Vapor Compression Refrigeration System: ANN based Multi-Objective Optimization
    Khan, Yasin
    Naqib-Ul-Islam, S.M.
    Faruque, Md Walid
    Ehsan, M. Monjurul
    Thermal Science and Engineering Progress, 2024, 49
  • [12] Energy, exergy, economic and environmental (4E) analyses based comparative performance study and optimization of vapor compression-absorption integrated refrigeration system
    Jain, Vaibhav
    Sachdeva, Gulshan
    Kachhwaha, Surendra Singh
    ENERGY, 2015, 91 : 816 - 832
  • [13] Thermo-economic and environmental analyses based multi-objective optimization of vapor compression-absorption cascaded refrigeration system using NSGA-II technique
    Jain, Vaibhav
    Sachdeva, Gulshan
    Kachhwaha, Surendra Singh
    Patel, Bhavesh
    ENERGY CONVERSION AND MANAGEMENT, 2016, 113 : 230 - 242
  • [14] Design and multi-objective optimization of a multi-generation system based on PEM electrolyzer, RO unit, absorption cooling system, and ORC utilizing machine learning approaches; a case study of Australia
    Shakibi, Hamid
    Faal, Mehrdad Yousefi
    Assareh, Ehsanolah
    Agarwal, Neha
    Yari, Mortaza
    Latifi, Seyed Ali
    Ghodrat, Maryam
    Lee, Moonyong
    ENERGY, 2023, 278