共 7 条
Experimental investigation on the impact of the asymmetrical heat exchange and operation modes on the thermal performance of a bored energy pile in unsaturated soil: A case study in Brazil
被引:0
|作者:
Formigari, Ricardo Caires
[1
]
Tsuha, Cristina de Hollanda Cavalcanti
[1
]
机构:
[1] Univ Sao Paulo, Dept Geotech Engn, Ave Trabalhador Saocarlense 400, BR-13566590 Sao Carlos, SP, Brazil
来源:
关键词:
Energy piles;
Unsaturated soils;
Thermal performance tests (TPT);
Hot-dominated climates;
Unbalanced load heat exchanger pipe configuration operation mode;
DESIGN;
FOUNDATION;
SIMULATION;
EFFICIENCY;
BEHAVIOR;
SYSTEM;
STATE;
D O I:
10.1016/j.geothermics.2024.103201
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
Energy piles are a type of geothermal exchanger, used in ground source heat pump systems, to provide heating or cooling energy for thermal comfort purposes, due to their cost advantages compared to deep borehole heat exchangers. This type of technology is still not used in Brazil, where the hot dominating weather and spacecooling demand predominate, and soils in unsaturated condition cover a significant part of the land surface. In this case of unbalanced heat transfer to the ground, this system may cause the increase of pile and ground temperatures over time, reducing its efficiency. Additionally, in unsaturated soils the ground thermal conductivity is normally inferior compared to saturated soils, and for this reason the increase of pile and ground temperatures with time may be more significant. Moreover, the positive impact of a groundwater flow on the heat transfer performance does not occur. Therefore, the current work investigates the thermal performance of energy piles with three different heat exchanger pipe configurations, in a typical Brazilian unsaturated tropical soil, with the aim of providing fundamental guidance for future application of this sustainable technology for the challenging combination of predominant cooling demand and unsaturated soil condition. For this study, asymmetrical and spiral pipe configurations and different operation modes were evaluated by field experiments to verify if these variables can influence the energy pile performance. Thermal performance tests were carried out on bored energy piles installed at a site of unsaturated soil in Sao Carlos city, Brazil. The energy pile of asymmetrical W-pipe configuration under intermittent operation mode presented a better heat transfer performance, and a lower increase of the average pile temperature compared to the spiral configuration case. These aspects can be advantageous for energy pile groups and also for the heat transfer performance and thermomechanical behaviour of a single energy pile.
引用
收藏
页数:16
相关论文