Experimental investigation of thermal performance of ground source heat pump system for summer and monsoon seasons of Himalayan region of India: A case study

被引:2
|
作者
Kumar, Satish [1 ]
Murugesan, Krishnan [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, India
基金
英国工程与自然科学研究理事会;
关键词
Ground source heat pump system; Borehole heat exchanger; Air-conditioning; Psychrometric process; Coefficient of performance; COOLING PERFORMANCE; U-TUBE; ENERGY; SIMULATION; EFFICIENCY; EXCHANGER;
D O I
10.1016/j.renene.2024.121842
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present experimental research work examines the thermal interactions of borehole heat exchangers on the ground side and psychrometric process involved inside the room during cooling mode operation using a ground source heat pump system (GSHP). An experimental facility of 17.5 kW cooling capacity GSHP system, consisting of five parallelly connected double U-tube borehole heat exchangers fitter with a commercially available heat pump system has been employed. The experiments were performed during peak summer and monsoon (rainy) seasons for space cooling applications for 45 hours of continuous operation in a city located in the Himalayan range of India. Analysis of results obtained indicate that during the summer season the hourly heat rejected to the ground is maximum for peak weather conditions due to high cooling load demand on the user side. On increasing the building load (increase in ambient temperature), there is a slight decrease in COPsys in both the seasons. During heavy rain season, the latent cooling load increases up to 1.5 times of the sensible cooling load. The average value of sensible heat factor is found to be 0.6 for the case of the peak summer season and 0.51 for the rainy season.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Experimental study of thermal performance of a ground source heat pump system installed in a Himalayan city of India for composite climatic conditions
    Sivasakthivel, T.
    Murugesan, K.
    Kumar, Surya
    Hu, Pingfang
    Kobiga, P.
    ENERGY AND BUILDINGS, 2016, 131 : 193 - 206
  • [2] Experimental investigation of thermal performance of a ground source heat pump system for spring season
    Mao, Qianjun
    Chen, Yufeng
    ENERGY AND BUILDINGS, 2017, 152 : 336 - 340
  • [3] Study of technical, economical and environmental viability of ground source heat pump system for Himalayan cities of India
    Sivasakthivel, T.
    Murugesan, K.
    Sahoo, P. K.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 48 : 452 - 462
  • [4] Experimental investigation and performance analysis on ground source heat pump system for greenhouse cooling
    Chai, Lilong
    Ma, Chengwei
    Zhang, Xiaohui
    Qu, Mei
    Chen, Qingyun
    Yu, Fei
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2008, 24 (12): : 150 - 154
  • [5] Experimental investigation of the cooling performance of a ground source heat pump system in Denizli, Turkey
    Karabacak, Rasim
    Acar, Sengul Guven
    Kumsar, Halil
    Gokgoz, Ali
    Kaya, Mustafa
    Tulek, Yahya
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (02): : 454 - 465
  • [6] Experimental thermal performance evaluation of a horizontal ground-source heat pump system
    Inalli, M
    Esen, H
    APPLIED THERMAL ENGINEERING, 2004, 24 (14-15) : 2219 - 2232
  • [7] Experimental investigation of ground-source heat pump system coupled to vertical and horizontal ground loops: A case study
    Kerme, Esa Dube
    Alzahrani, Waleed Saeed
    Fung, Alan S.
    Leong, Wey H.
    RENEWABLE ENERGY, 2024, 236
  • [8] Analysis of thermal performance and economy of ground source heat pump system: a case study of the large building
    Han, Jingyang
    Cui, Minghui
    Chen, Junyi
    Lv, Wenjuan
    GEOTHERMICS, 2021, 89
  • [9] Experimental investigation and control optimization of a ground source heat pump system
    Xia, Lei
    Ma, Zhenjun
    McLauchlan, Craig
    Wang, Shugang
    APPLIED THERMAL ENGINEERING, 2017, 127 : 70 - 80
  • [10] The Experimental Thermal Performance Analysis of the Ground Source Heat Pump System Dependent on Environmental Conditions
    Karabacak, R.
    Acar, S. Gueven
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2010, 32 (12) : 1142 - 1158