Experimental study on tensile properties of semi-grouting sleeve after high temperature

被引:0
|
作者
Zhu J.-N. [1 ,2 ]
Guo D.-D. [1 ]
Ma J.-F. [1 ]
Wu Y.-P. [1 ]
Ma J.-J. [1 ]
机构
[1] School of Civil Engineering, Xi'an University of Architecture & Technology, Xi'an
[2] Key Lab of Structural Engineering and Earthquake Resistance, Ministry of Education (XAUAT), Xi'an
来源
Gongcheng Lixue/Engineering Mechanics | 2020年 / 37卷 / 05期
关键词
Anchoring length; Cementitious grout; Failure mode; High temperature; Semi-grouting sleeves;
D O I
10.6052/j.issn.1000-4750.2019.06.0322
中图分类号
学科分类号
摘要
The compressive strength test and uniaxial tensile test of standard test block of grouting material and cast iron semi-grouting sleeve connector were carried out at room temperature, 200℃, 300℃, 400℃ and 600℃, respectively. The influence of temperature on the performance of grouting material, and the influence of anchoring length and protective layer thickness on the tensile properties of semi-grouting sleeve connection specimen after high temperature were studied, and the change of failure mode of semi-grouting sleeve connection after high temperature was analyzed. The results showed that the compressive strength of grouting material decreased with the increase of temperature, and that the loss of compressive strength of grouting material was 73% after 600℃ temperature. After high temperature, the fracture failure of sleeve specimen gradually changed from steel-bar yield failure to steel bar yield pull-out failure, and finally became pull-out failure of steel bar before yielding, and the tensile performance of unprotected specimens were lower than that of protected specimens at all cases of temperature. Based on the test data, the calculation formula is respectively developedfor the compressive strength of grouting material varying with temperature and for the ultimate tensile force of semi-grouting sleeve varying with temperature and with anchoring length, which provided a reference for related design and engineering construction. © 2020, Engineering Mechanics Press. All right reserved.
引用
收藏
页码:104 / 111
页数:7
相关论文
共 17 条
  • [11] Zhang H., Zhang R., Bai Y., Et al., Fire resistance limit and safety analysis of steel frame assemblies, Engineering Mechanics, 8, pp. 121-126, (2008)
  • [12] Song T., Han L., Some new developments of the fire performance research on composite structures, Engineering Mechanics, 25, pp. 230-253, (2008)
  • [13] GB/T50448-2015, Technical code for application of cementitious grout, (2015)
  • [14] Wang G., Experiment study on connection behaviour of gout-filled pipe splices connector in hightemperature, (2017)
  • [15] Yu Q., Yuan W., You G., Experiment and finite element analysis on bonding properties between deformed bars and grouting material, Structural Engineers, 32, 6, pp. 113-122, (2016)
  • [16] Xiao J., Huang J., Zhao Y., On bond behavior between HPC and fine grain steel bar after elevated temperatures, Journal of Tongji University (Natural Science), 37, 10, pp. 1296-1301, (2009)
  • [17] Li W., Guo Z., Experimental investigation of strength and deformation of concrete at elevated temperature, Journal of Building Structures, 14, 1, pp. 8-16, (1993)