Long-Term Radiometric Stability of Uncooled and Shutterless Microbolometer-Based Infrared Cameras

被引:0
|
作者
Gazzano, Olivier [1 ]
Chambon, Mathieu [1 ]
Ferrec, Yann [1 ]
Druart, Guillaume [1 ]
机构
[1] Univ Paris Saclay, DOTA, ONERA, F-91120 Palaiseau, France
关键词
long-wave infrared; microbolometer; radiometric calibration; imaging system; NONUNIFORMITY CORRECTION; CALIBRATION;
D O I
10.3390/s24196387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Uncooled and shutterless microbolometer cameras are good candidates for infrared imaging systems installed on small satellites or small unmanned aerial vehicles: they are light and passive since no cooling system or mechanical shutter is required and they can be operated at ambient temperatures. However, the radiometric compensation has to be carefully performed to make the system compatible with applications where the radiometric accuracy of the images is mandatory. In this paper, we study the impact of the camera environment to the radiometric accuracy of the images. We propose and test hardware and software solutions to improve this accuracy and the quality of the radiometric images. We show that the radiometric calibration of the camera with our model is valid over a long time period- about 3 years-using in-door experiments.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Long-Term Stability in Orthodontics
    Jones, David
    SPECIAL CARE IN DENTISTRY, 2012, 32 (01) : 32 - 32
  • [42] Long-term stability of slopes
    Ter-Martirosian, Z. G.
    Proshin, M. V.
    Proceedings of the 16th International Conference on Soil Mechanics and Geotechnical Engineering, Vols 1-5: GEOTECHNOLOGY IN HARMONY WITH THE GLOBAL ENVIRONMENT, 2005, : 2587 - 2590
  • [43] Long-term stability - Comment
    Arnone, R
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (02) : A17 - A18
  • [44] Long-term infrared photometry of Seyferts
    Glass, IS
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2004, 350 (03) : 1049 - 1066
  • [45] Long-term Stability of LSM-YSZ Based Cathodes
    Baque, L. C.
    Jorgensen, P. S.
    Hansen, K. V.
    Sogaard, M.
    SOLID OXIDE FUEL CELLS 13 (SOFC-XIII), 2013, 57 (01): : 2027 - 2036
  • [46] REPROCESSING OF SUOMI NPP CRIS SENSOR DATA RECORDS AND IMPACTS ON RADIOMETRIC AND SPECTRAL LONG-TERM ACCURACY AND STABILITY
    Chen, Yong
    Han, Yong
    Weng, Fuzhong
    2017 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2017, : 4178 - 4181
  • [47] Reprocessing of Suomi NPP CrIS Sensor Data Records to Improve the Radiometric and Spectral Long-Term Accuracy and Stability
    Chen, Yong
    Iturbide-Sanchez, Flavio
    Tremblay, Denis
    Tobin, David
    Strow, Larrabee
    Wang, Likun
    Mooney, Daniel L.
    Johnson, David
    Predina, Joe
    Suwinski, Lawrence
    Revercomb, Henry E.
    Sun, Ninghai
    Zhang, Bin
    Cao, Changyong
    Kalluri, Satya
    Zhou, Lihang
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [48] Optimization of a Deep Convective Cloud Technique in Evaluating the Long-Term Radiometric Stability of MODIS Reflective Solar Bands
    Mu, Qiaozhen
    Wu, Aisheng
    Xiong, Xiaoxiong
    Doelling, David R.
    Angal, Amit
    Chang, Tiejun
    Bhatt, Rajendra
    REMOTE SENSING, 2017, 9 (06):
  • [49] Detection and Long-Term Analysis of Anomalous Pixels Based on Scene and On-Orbit Radiometric Traceability
    Zhao, Xue
    Hu, Zhuoyue
    Bian, Ji
    Wang, Qiyao
    Zhu, Min
    Chen, Fansheng
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2024, 21
  • [50] LONG-TERM STABILITY OF HYDROGENATED AMORPHOUS-GERMANIUM MEASURED BY INFRARED-ABSORPTION
    GHAZALA, MA
    BEYER, W
    WAGNER, H
    JOURNAL OF APPLIED PHYSICS, 1991, 70 (08) : 4540 - 4543