Long-Term Radiometric Stability of Uncooled and Shutterless Microbolometer-Based Infrared Cameras

被引:0
|
作者
Gazzano, Olivier [1 ]
Chambon, Mathieu [1 ]
Ferrec, Yann [1 ]
Druart, Guillaume [1 ]
机构
[1] Univ Paris Saclay, DOTA, ONERA, F-91120 Palaiseau, France
关键词
long-wave infrared; microbolometer; radiometric calibration; imaging system; NONUNIFORMITY CORRECTION; CALIBRATION;
D O I
10.3390/s24196387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Uncooled and shutterless microbolometer cameras are good candidates for infrared imaging systems installed on small satellites or small unmanned aerial vehicles: they are light and passive since no cooling system or mechanical shutter is required and they can be operated at ambient temperatures. However, the radiometric compensation has to be carefully performed to make the system compatible with applications where the radiometric accuracy of the images is mandatory. In this paper, we study the impact of the camera environment to the radiometric accuracy of the images. We propose and test hardware and software solutions to improve this accuracy and the quality of the radiometric images. We show that the radiometric calibration of the camera with our model is valid over a long time period- about 3 years-using in-door experiments.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Compensating internal temperature effects in uncooled microbolometer-based infrared cameras
    Pedreros, Felipe
    Pezoa, Jorge E.
    Torres, Sergio N.
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XXIII, 2012, 8355
  • [2] Shutterless non-uniformity correction for the long-term stability of an uncooled long-wave infrared camera
    Liu, Chengwei
    Sui, Xiubao
    Gu, Guohua
    Chen, Qian
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (02)
  • [3] Microbolometer arrays enable uncooled infrared cameras
    Hecht, Jeff
    LASER FOCUS WORLD, 2012, 48 (04): : 70 - 74
  • [4] Microbolometer-based MWIR infrared camera
    Budzier, Helmut
    Krause, Volker
    Gerlach, Gerald
    Wassiliew, Dimitar
    TM-TECHNISCHES MESSEN, 2007, 74 (09) : 450 - 455
  • [5] Modeling transient thermal behavior of shutter-less microbolometer-based infrared cameras
    Tempelhahn, A.
    Budzier, H.
    Krause, V.
    Gerlach, G.
    ELECTRO-OPTICAL AND INFRARED SYSTEMS: TECHNOLOGY AND APPLICATIONS XI, 2014, 9249
  • [6] THz Imaging and Radiometric Measurements Using a Microbolometer-based Camera
    Bolduc, M.
    Terroux, M.
    Marchese, L.
    Tremblay, B.
    Savard, E.
    Doucet, M.
    Oulachgar, H.
    Alain, C.
    Jeronimek, H.
    Bergeron, A.
    2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
  • [7] Radiometric cloud imaging with an uncooled microbolometer thermal infrared camera
    Shaw, JA
    Nugent, PW
    Pust, NJ
    Thurairajah, B
    Mizutani, K
    OPTICS EXPRESS, 2005, 13 (15): : 5807 - 5817
  • [8] Improving the shutter-less compensation method for TEC-less microbolometer-based infrared cameras
    Tempelhahn, A.
    Budzier, H.
    Krause, V.
    Gerlach, G.
    INFRARED TECHNOLOGY AND APPLICATIONS XLI, 2015, 9451
  • [9] Noise-equivalent power characterization of an uncooled microbolometer-based THz imaging camera
    Bolduc, Martin
    Terroux, Marc
    Tremblay, Bruno
    Marchese, Linda
    Savard, Eric
    Doucet, Michel
    Oulachgar, Hassane
    Alain, Christine
    Jerominek, Hubert
    Bergeron, Alain
    TERAHERTZ PHYSICS, DEVICES, AND SYSTEMS V: ADVANCE APPLICATIONS IN INDUSTRY AND DEFENSE, 2011, 8023
  • [10] Calibration of uncooled LWIR microbolometer imagers to enable long-term field deployment
    Nugent, Paul W.
    Shaw, Joseph A.
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XXV, 2014, 9071