Evaluating manganese removal in groundwater using pilot scale biofilters: The role of filter media characteristics during start-up

被引:1
|
作者
Arora, Hemant [1 ]
Peldszus, Sigrid [1 ]
Lamba-Rautapuro, Nicholas [2 ]
Slawson, Robin [2 ]
Kendall, Brian [3 ]
Huck, Peter M. [1 ]
机构
[1] Univ Waterloo, Dept Civil & Environm Engn, Waterloo, ON N2L 3G1, Canada
[2] Wilfrid Laurier Univ, Dept Biol, Waterloo, ON N2L 3C5, Canada
[3] Univ Waterloo, Dept Earth & Environm Sci, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Iron; ATP; Manganese oxides; Pore size distribution; Manganese oxidizing bacteria; Filter media; Groundwater; IRON; KINETICS; MN(II); WATER; BIRNESSITE; ADSORPTION; FE(II); OXIDES; MN2+; O-2;
D O I
10.1016/j.watres.2024.122711
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the influence of filter media characteristics on manganese (Mn) removal in groundwater biofilters during the start-up phase. Six pilot scale biofilters containing three different granular activated carbons (GAC), two anthracite, and one sand media were run for 133 days to examine their Mn removal performance at a drinking water utility, while also monitoring ATP and bacterial growth as indicators of biological activity. Key findings demonstrate the critical role of media characteristics, especially for GAC media. Initial Mn adsorption on GAC, with its higher surface area, higher macropore volume, and surface charge, promoted physicochemical and biological oxidation, thus contributing to the early onset of Mn removal during the start-up of the GAC biofilters. In contrast, biological processes dominated Mn removal on anthracite and sand biofilters during start-up. As expected, the presence of Mn-oxidizing bacteria was detected in biofilters, and ATP levels were correlated to Mn removal until the biofilters were acclimated, showing the potential of ATP as an acclimation monitoring metric. Once acclimated, all biofilters consistently reduced Mn levels from 60.9 +/- 4.5 mu g/L to below 5 mu g/L (>90 % removal), while concurrently removing iron, thereby highlighting the biofilter's effectiveness at low water temperatures (<15 C-degrees). This study demonstrates the advantage of GAC media for Mn removal in biofilters during start-up in regions with lower water temperatures.
引用
收藏
页数:11
相关论文
共 42 条
  • [31] IDENTIFICATION OF METAL TEMPERATURE DISTRIBUTION IN STEAM TURBINE DURING START-UP OPERATION USING PARTICLE FILTER AND MODEL ORDER REDUCTION
    Ito, Hiroshi
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 2D, 2019,
  • [32] Insights into the start-up of acidic nitritation using conventional activated sludge: Process dynamics, nitrifiers succession, and pilot-scale demonstration
    Kong, Zheng
    Wang, Zhiyao
    Hu, Zhetai
    Song, Yunqian
    Xu, Dongdong
    Li, Guanbin
    Dwyer, Jason
    Hu, Shihu
    WATER RESEARCH, 2025, 275
  • [33] Bacterial growth during the start-up period of pilot-scale biological activated carbon filters: Effects of residual ozone and chlorine and backwash intervals
    Lohwacharin, Jenyuk
    Phetrak, Athit
    Takizawa, Satoshi
    Kanisawa, Yuuma
    Okabe, Sadao
    PROCESS BIOCHEMISTRY, 2015, 50 (10) : 1640 - 1647
  • [34] Evolution of N-converting bacteria during the start-up of anaerobic digestion coupled biological nitrogen removal pilot-scale bioreactors treating high-strength animal waste slurry
    Anceno, Alfredo J.
    Rouseau, Pierre
    Beline, Fabrice
    Shipin, Oleg V.
    Dabert, Patrick
    BIORESOURCE TECHNOLOGY, 2009, 100 (14) : 3678 - 3687
  • [35] Fault detection of industrial large-scale gas turbine for fuel distribution characteristics in start-up procedure using artificial neural network method
    Park, Yeseul
    Choi, Minsung
    Choi, Gyungmin
    ENERGY, 2022, 251
  • [36] Fault detection of industrial large-scale gas turbine for fuel distribution characteristics in start-up procedure using artificial neural network method
    Park, Yeseul
    Choi, Minsung
    Choi, Gyungmin
    Energy, 2022, 251
  • [37] Systematic analysis of biomass characteristics associated membrane fouling during start-up of a hybrid membrane bioreactor using worm reactor for sludge reduction
    Li, Zhipeng
    Tian, Yu
    Ding, Yi
    Lu, Yaobin
    BIORESOURCE TECHNOLOGY, 2013, 136 : 155 - 162
  • [38] Unveiling the characterization and development of prokaryotic community during the start-up and long-term operation of a pilot-scale anaerobic membrane bioreactor for the treatment of real municipal wastewater
    Kong, Zhe
    Li, Lu
    Wu, Jiang
    Rong, Chao
    Wang, Tianjie
    Chen, Rong
    Sano, Daisuke
    Li, Yu-You
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 813
  • [39] Rapid start-up of an innovative pilot-scale staged PN/A continuous process for enhanced nitrogen removal from mature landfill leachate via robust NOB elimination and efficient biomass retention
    Jiang, Cancan
    Zhang, Liang
    Chi, Yongzhi
    Xu, Shengjun
    Xie, Yawen
    Yang, Dongmin
    Qian, Yunzhi
    Chen, Fuqiang
    Zhang, Weijun
    Wang, Dongsheng
    Tian, Zhe
    Zhang, Shujun
    Li, Yu-You
    Zhuang, Xuliang
    WATER RESEARCH, 2024, 249
  • [40] Investigation on transient behavior of residual heat removal pumps in 1000 MW nuclear power plant using a 1D-3D coupling methodology during start-up period
    Zhou, Banglun
    Yuan, Jianping
    Lu, Jiaxing
    Hong, Feng
    ANNALS OF NUCLEAR ENERGY, 2017, 110 : 560 - 569