A comprehensive low voltage ride through control strategy of wind turbine driven double-fed induction generation adapted to multi-type faults

被引:0
|
作者
机构
[1] Yu, Fang
[2] Liu, Qihui
[3] Xie, Mengli
[4] Zhang, Jianhua
来源
Yu, F. (125610805@qq.com) | 1600年 / Automation of Electric Power Systems Press卷 / 37期
关键词
Wind farm - Asynchronous generators - Electric power transmission networks - Electric fault currents - Electric power system control - Electric equipment protection - Reactive power - Electric power system protection - Power control - Timing circuits;
D O I
10.7500/AEPS201202057
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [42] Research on Low Voltage Ride-through Control of Permanent Magnet Direct Drive Wind Turbine Generators during Grid Faults
    Meng, Jingjia
    2024 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, ICMA 2024, 2024, : 824 - 828
  • [43] Coordinated Control Approaches for Low-Voltage Ride-Through Enhancement in Wind Turbines With Doubly Fed Induction Generators
    Rahimi, Mohsen
    Parniani, Mostafa
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (03) : 873 - 883
  • [44] Doubly fed induction generator wind turbines: A novel integrated protection circuit for low-voltage ride-through strategy
    Justo, Jackson John
    Mwasilu, Francis
    Jung, Jin-Woo
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (05)
  • [45] Research on Low and High Voltage Interlocking Fault Ride-Through Control Strategy for Doubly-Fed Wind Turbines
    Zhu, Darui
    Cheng, Jiakang
    Chen, Jie
    Duan, Jiandong
    PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 2, ICWPT 2023, 2024, 1159 : 403 - 411
  • [46] Closure to Discussion on "A Genetic Algorithm-Based Low Voltage Ride-Through Control Strategy for Grid Connected Doubly Fed Induction Wind Generators"
    Vrionis, Theodoros
    Koutiva, Xanthi
    Vovos, Nicholas A.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (01) : 549 - 549
  • [47] Low Voltage Ride through Method to Enhance DC-link Voltage Stability in Grid-Connected Doubly Fed Induction Generator Wind Turbine
    Ngom, Ibrahima
    Mboup, Alioune Baadara
    Diop, Moustapha
    Ndiaye, Alphousseyni
    Thiam, Mouhamadou
    Thiaw, Lamine
    INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ENERGY TECHNOLOGIES (ICECET 2021), 2021, : 384 - 388
  • [48] Low voltage ride through of doubly-fed induction generator connected to the grid using sliding mode control strategy
    Saad, Naggar H.
    Sattar, Ahmed A.
    Mansour, Abd El-Aziz M.
    RENEWABLE ENERGY, 2015, 80 : 583 - 594
  • [49] Research on suppression strategy of IGBT junction temperature rise for doubly-fed wind turbine converter under low voltage ride through
    Wang, Zhihao
    Zhang, Xinyan
    Qiu, Yanjiang
    Zhao, Xiaoyue
    Shi, Sisi
    Zhou, Dengyu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (10): : 259 - 267
  • [50] A low-voltage ride-through capability enhancement scheme of doubly fed induction generator based wind plant considering grid faults
    Gayen, P. K.
    Chatterjee, D.
    Goswami, S. K.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2016, 8 (02)