Low global warming potential R1234yf in a mobile air-conditioning system: a study on performance prediction using different machine learning approaches

被引:0
|
作者
Prabakaran, Rajendran [1 ]
Gomathi, B. [2 ]
Jeyalakshmi, P. [3 ]
Thangamuthu, Mohanraj [4 ]
Lal, Dhasan Mohan [5 ]
Kim, Sung Chul [1 ]
机构
[1] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[2] PSG Inst Technol & Appl Res, Dept Comp Sci & Engn, Coimbatore 641062, India
[3] Hindusthan Coll Engn & Technol, Dept Mech Engn, Coimbatore 641032, India
[4] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Mech Engn, Coimbatore, India
[5] Anna Univ, Dept Mech Engn, Refrigerat & Air Conditioning Div, Chennai 600025, India
关键词
Mobile air-conditioning; Artificial neural networks; Simple recurrent neural networks; Extreme gradient boosting; Coefficient of performance; Exergy efficiency; REFRIGERANT R1234YF; OPTIMIZATION; SIMULATION;
D O I
10.1007/s10973-024-13715-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Machine learning (ML) approaches have admirable potential to forecast the performance of the mobile air-conditioning (MAC) system with low global warming potential R1234yf instead of conventional mathematical and simulation approaches. In this work, three different ML algorithms-artificial neural network (ANN), simple recurrent neural network (SRNN), and extreme gradient boosting (XGB)-have been employed for predicting the energy and exergy performance. Compressor speed, condenser-side air velocity/temperature, and evaporator-side air flow rate/temperature were considered as influencing input parameters. In energy analysis, performance indexes, namely refrigerant flow rate, cooling capacity, compressor power, and coefficient of performance (COP), were considered as output parameters, while total exergy destruction and exergy efficiency (eta ex) were accounted for as exergy metrics. First, the heat mapping method was used to rank the correlation among the input and output factors, and results revealed that compressor speed and evaporator-side air temperature are identified as the most and least influencing parameters on the forecast of energy and exergy performance metrics. Among the three models, the use of the XGB model showed excellent prediction efficiency on COP and eta ex with root-mean-squared error of 0.0756 and 0.9786, respectively, while the corresponding correlation coefficients were 0.9749 and 0.9119. Predicting eta ex using ANN and SRNN showed weak performance with a determination coefficient less than 0.70; moreover, prediction performance on energy indexes using ANN and SRNN models was good and almost identical. Overall, it is inferred that using XGB over ANN and SRNN can deliver superior prediction efficiency with enhanced reliability and can be employed as a forecasting platform for MACs under widespread working conditions.
引用
收藏
页码:14415 / 14432
页数:18
相关论文
共 42 条
  • [21] Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems
    Meng, Zhaofeng
    Zhang, Hua
    Lei, Mingjing
    Qin, Yanbin
    Qiu, Jinyou
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 : 362 - 370
  • [22] Drop-in Performance Analysis and Effect of IHX for an Automotive Air Conditioning System with R1234yf as a Replacement of R134a
    Direk, Mehmet
    Kelesoglu, Alper
    Akin, Ahmet
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2017, 63 (05): : 314 - 319
  • [23] Performance of Automotive Ultra-Low Temperature Economized Vapor Injection Heat Pump Air Conditioning Using R1234yf Refrigerant
    Liu Y.
    Li W.
    Zhang L.
    Shi J.
    Chen J.
    Chen, Jiangping (jpchen_sjtu@163.com), 2020, Shanghai Jiaotong University (54): : 1108 - 1116
  • [24] Experimental study on evaporator performance in mobile air conditioning system using HFO-1234yf as working fluid
    Qi, Zhaogang
    APPLIED THERMAL ENGINEERING, 2013, 53 (01) : 124 - 130
  • [25] Experimental investigation of performance and exergy analysis of automotive air conditioning systems using refrigerant R1234yf at various compressor speeds
    Cho, Honghyun
    Park, Chasik
    APPLIED THERMAL ENGINEERING, 2016, 101 : 30 - 37
  • [26] R152a-R13I1 mixture as an alternative to R1234yf for a mobile air conditioning: an estimation of flammability properties, thermodynamic and environmental performance
    Mayakrishnan, Chelliah
    Prabakaran, Rajendran
    Lal, Dhasan Mohan
    Kim, Sung Chul
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (22) : 13095 - 13115
  • [27] Performance augmentation of retrofitted sustainable R1234yf in R134a air conditioning system using Al2O3-SiO2 hybrid nanolubricant
    Sharif, M. Z.
    Azmi, W. H.
    Ghazali, M. F.
    Ali, Hafiz Muhammad
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (19) : 10203 - 10215
  • [28] Performance augmentation of retrofitted sustainable R1234yf in R134a air conditioning system using Al2O3–SiO2 hybrid nanolubricant
    M. Z. Sharif
    W. H. Azmi
    M. F. Ghazali
    Hafiz Muhammad Ali
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 10203 - 10215
  • [29] Measurements and modeling of the vapor-liquid equilibrium properties of low-global-warming-potential refrigerant R32/R1234yf/R1123 ternary mixtures
    Miyamoto, Hiroyuki
    Nakamura, Yuuhei
    Minai, Kyouhei
    Yamada, Tessei
    FLUID PHASE EQUILIBRIA, 2022, 558
  • [30] The Effect of Internal Heat Exchanger Using R1234ze(E) as an Alternative Refrigerant in a Mobile Air-Conditioning System
    Direk, Mehmet
    Soylu, Eren
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2018, 64 (02): : 114 - 120