Field tests elimination of the gas temperature deviation in large scale, advanced low NOx, tangentially fired pulverized coal boiler

被引:0
|
作者
机构
[1] Liu, Fuguo
[2] Xu, Wei
[3] Hu, Daijun
[4] Xian, Lanhui
来源
Liu, F. (lephico@163.com) | 1600年 / Chinese Mechanical Engineering Society卷 / 49期
关键词
27;
D O I
10.3901/JME.2013.18.159
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Numerical simulation on gas temperature deviation in a coal fired 1025t/h boiler
    Xu, Minghou
    Yuan, Jianwei
    Ding, Shifa
    Cao, Handing
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 1996, 16 (04): : 266 - 270
  • [32] Industrial Experiment on NOx Reduction by Urea Solution Injection in the Fuel-Rich Zone of a 330 MW Tangentially Pulverized Coal-Fired Boiler
    Bai, Hao
    Zhang, Zhongxiao
    Li, Zixiang
    Wu, Xiaojiang
    Guo, Xinwei
    Zhang, Jian
    Bi, Degui
    ACS OMEGA, 2022, 7 (14): : 11853 - 11861
  • [33] Impact of co-firing lean coal on NOx emission of a large-scale pulverized coal-fired utility boiler during partial load operation
    Yang Zheng
    Xiaotao Gao
    Changdong Sheng
    Korean Journal of Chemical Engineering, 2017, 34 : 1273 - 1280
  • [34] INFLUENCE OF BLADE ABSENCE ON PERFORMANCE OF DC TYPE LOW-NOX BURNER FOR PULVERIZED-COAL FIRED BOILER
    Wang, Zhiqiang
    Dong, Yong
    Sun, Shaozeng
    CBEE 2009: PROCEEDINGS OF THE 2009 INTERNATIONAL CONFERENCE ON CHEMICAL, BIOLOGICAL AND ENVIRONMENTAL ENGINEERING, 2010, : 404 - +
  • [35] Experimental investigations on visualization of three-dimensional temperature distributions in a large-scale pulverized-coal-fired boiler furnace
    Zhou, HC
    Lou, C
    Cheng, Q
    Jiang, ZW
    He, J
    Huang, BY
    Pei, ZL
    Lu, CX
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2005, 30 : 1699 - 1706
  • [36] An analysis of the cause leading to steam temperature deviation in a large-sized tangentially fired boiler and measures taken for its alleviation
    Zhang, Y.
    Li, P.-Y.
    Fu, Z.-H.
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 2001, 16 (03): : 336 - 337
  • [37] Numerical study of NOx reduction by reburning mechanically-activated micronized coal in a full-scale tangentially-fired boiler
    Chernetskiy, M.
    Dekterev, A.
    Hanjalic, K.
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON TURBULENCE HEAT AND MASS TRANSFER (THMT-15), 2015, : 779 - 782
  • [38] Optimization of operating conditions to achieve combustion stability and reduce NOx emission at half-load for a 550-MW tangentially fired pulverized coal boiler
    Jiang, Yu
    Lee, Byoung-Hwa
    Oh, Dong-Hun
    Jeon, Chung-Hwan
    FUEL, 2021, 306
  • [39] Effects of burner tilt angle on the combustion and NOx emission characteristics of a 700 MWe deep-air-staged tangentially pulverized-coal-fired boiler
    Tan, Peng
    Tian, Dengfeng
    Fang, Qingyan
    Ma, Lun
    Zhang, Cheng
    Chen, Gang
    Zhong, Lijin
    Zhang, Honggang
    FUEL, 2017, 196 : 314 - 324
  • [40] Application of the computational method for predicting NOx reduction within large scale coal-fired boiler
    Adamczyk, Wojciech P.
    Werle, Sebastian
    Ryfa, Arkadiusz
    APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 343 - 350