Automatic system for deformation measurement of anodes in an electrolytic process

被引:0
|
作者
delacalle, F. J. [1 ]
Fernandez, A. [2 ]
Lema, D. G. [1 ]
Usamentiaga, R. [1 ]
Garcia, D. F. [1 ]
机构
[1] Univ Oviedo, Campus Gijon, Gijon 33204, Asturias, Spain
[2] Iturcemi SL, Ave Siderurgia, Aviles 33490, Asturias, Spain
关键词
Industrial automation; Computer vision; Industrial control; Electrolysis; Industrial inspection; Image processing; INSPECTION;
D O I
10.1016/j.measurement.2024.115626
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper proposes a novel system for measuring the deformation of anodes automatically in an electrolytic process, eliminating the need for manual intervention. The system employs cameras to acquire lateral perspective images of the anodes. These images are processed using a computer vision algorithm to give measurements of anode deformation, while considering potential errors arising from scene and object geometry. The system's results align with measurements conducted by operators across 71 anodes and were validated over 3900 more anodes in four different locations under different lightning and environmental conditions. This system improves efficiency, by automating a task that was previously carried out manually, and also safety by eliminating the operators need of handling heavy loads and operating in hazardous environments.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Investigation of anodes for production of electrolytic zinc
    Hanley, HR
    Clayton, CY
    Walsh, DF
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1930, 91 : 275 - 282
  • [22] Electrolytic tinning lines with soluble anodes
    Haupt, Werner
    Kuhlmann, Joachim
    Sasse, Caesar
    MPT Metallurgical Plant and Technology International, 2012, 35 (03): : 68 - 73
  • [23] Measurement Automation System for Aluminum Electrolytic Capacitor Development
    Kovacs, Laszlo
    Fodor, Denes
    Klug, Otto
    Enisz, Krisztian
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2013, 16 (03) : 38 - 43
  • [24] VISCOSITY MEASUREMENT AS USED FOR AUTOMATIC PROCESS MONITORING
    BROOKFIELD, DW
    MINARD, RA
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1961, 91 (04) : 838 - &
  • [25] ELECTROLYTIC MANUFACTURE OF SODIUM CHLORATE WITH MAGNETITE ANODES
    MATSUMUR.T
    ITAI, R
    SHIBUYA, M
    ISHI, G
    ELECTROCHEMICAL TECHNOLOGY, 1968, 6 (11-1): : 402 - &
  • [26] Use of bimetallic anodes in the electrolytic synthesis of alloys
    Bechard, C
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1933, 196 : 1480 - 1482
  • [27] OPTIMIZATION OF THE POROUS STRUCTURE OF THE ANODES OF ELECTROLYTIC CAPACITORS
    ORLOV, VM
    RYUNGENEN, TI
    NOVICHKOV, VY
    SOVIET POWDER METALLURGY AND METAL CERAMICS, 1986, 25 (11): : 885 - 888
  • [28] ELECTROLYTIC PRODUCTION OF PERCHLORATE BY LEAD DIOXIDE ANODES
    OSUGA, T
    FUJII, S
    SUGINO, K
    SEKINE, T
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1969, 116 (02) : 203 - &
  • [29] Investigation of anodes for production of electrolytic zinc, II
    Hanley, HR
    Clayton, CY
    Walsh, DF
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1931, 96 : 142 - 146
  • [30] Automatic processing of interferometric SAR and accuracy of surface deformation measurement
    Deguchi, Tomonori
    Kato, Masatane
    Akcin, Hakan
    Kutoglu, Hakan Senol
    SAR IMAGE ANALYSIS, MODELING, AND TECHNIQUES VIII, 2006, 6363