Analysis on equivalence between UHF discharge signals caused by voltage pulses artificially injected into gis and that caused by actual partial discharge signals inside GIS

被引:0
|
作者
机构
[1] Li, Duanjiao
[2] Zheng, Shusheng
[3] Li, Liang
[4] Li, Xingwang
[5] Wang, Zengbin
来源
Li, Duanjiao | 1600年 / Power System Technology Press卷 / 38期
关键词
Equivalence - On-site calibration - Partial discharge signal - Sensitivity - Testing platforms - Ultra-high frequency - Voltage pulse - Voltage waveforms;
D O I
10.13335/j.1000-3673.pst.2014.10.044
中图分类号
学科分类号
摘要
It is the key procedure for on-site calibration of the sensitivity of (ultra-high-frequency) UHF test system by artificially injecting the voltage pulse into GIS, which is equivalent to the partial discharge (PD) inside the GIS. The distribution differences of time-domain amplitudes and frequency spectrum of UHF signals caused by artificial voltage pulse and actual PD inside the GIS are researched by experiments. A PD testing platform based on 220 kV GIS equipments is constructed and inside the cavity near the outgoing line the UHV electromagnetic waves caused by artificial voltage pulses and PD defects are transmitted respectively and the UHF signals are received by four disc antennae fixed on typical positions. The amplitudes of UHF signals at different positions are measured and the attenuation degrees of UHF signals caused by artificial voltage pulses and PD signals are contrasted. Applying Fourier transform to signal waves, the frequency spectrum distributions of the two kinds of UHF signals are contrasted. Research results show that the UHF signal caused by artificial voltage pulse and passed through the circuit breaker is attenuated a little bit more than the UHF signals caused by PD; the frequency spectrum distribution of the UHF signal caused by artificial voltage pulse is close to that of the UHF signal caused by PD, besides, the rising time of the voltage waveform of artificial voltage pulse varies within the range from 0.3 ns to 1ns and it does not influence the frequency spectrum distribution of UHF electromagnetic wave. The obtained research results are available for reference to the on-site calibration of sensitivity of UHF test system.
引用
收藏
相关论文
共 39 条
  • [21] Frequency-domain Transmission Characteristics of Electromagnetic Wave Signals Excited by Partial Discharge in GIS
    Miao Peiqing
    Li Xiuwei
    Ye Haifeng
    Sheng Gehao
    Jiang Xiuchen
    2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 511 - 515
  • [22] Estimation of Time Difference Between Partial Discharge UHF Signals Using Differential Energy Method
    Zhu, Ming-Xiao
    Xue, Jian-Yi
    Zhang, Jia-Ning
    Deng, Jun-Bo
    Mu, Hai-Bao
    Zhang, Guan-Jun
    Guo, An-Xiang
    Liu, Xiao-Wei
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [23] Measurement and analysis for pulse sequence of partial discharge signals under DC voltage
    Si, Wenrong
    Li, Junhao
    Yuan, Peng
    Guo, Hong
    Luo, Yongfen
    Li, Yanming
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2010, 25 (03): : 164 - 171
  • [24] Analysis of Discharge Faults Between Flanges Caused by Transient Enclosure Voltage
    Li, Jisheng
    He, Zeyu
    Wang, Yu
    Chen, Xiaoyue
    Liu, Yongcong
    IEEE ACCESS, 2020, 8 : 10981 - 10988
  • [25] Partial Discharge Characteristics of Metallic Protrusion in GIS under Different Lightning Impulse Voltage Waveforms Based on UHF Method
    Han, Xutao
    Li, Junhao
    Zhang, Liang
    Liu, Zehui
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (06) : 3722 - 3729
  • [26] A Denoising Method for Partial Discharge Ultrasonic Signals in GIS Based on Ultra-High Frequency Signal Synchronization
    Li, Xing
    Ding, Dengwei
    Xu, Yuan
    Jiang, Jinpeng
    Chen, Xiaoxin
    Yuan, Minghu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (06) : 3316 - 3325
  • [27] The Study of Partial Discharge in GIS under Impulse Voltage Based on Time-frequency Analysis
    Ren, Zhong
    Dong, Ming
    Ren, Ming
    Zhou, Hai-bin
    Miao, Jin
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 694 - 697
  • [28] Time-frequency analysis of E-M signals emitted from a partial discharge occurring in GIS using Wavelet transform
    Kawada, M
    Kawasaki, ZI
    Matsu-ura, K
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 57 - 60
  • [29] Frequency Analysis and Distance Dependence of Transient Earth Voltage Signals from Partial Discharge Sources
    Nakayama, Megumi
    Okada, Sho
    Ueno, Hideki
    Mutakamihigashi, Tatsuya
    IEEJ Transactions on Fundamentals and Materials, 2024, 144 (09) : 385 - 391
  • [30] Study on the Relationship between the Size of Resin Sprue on GIS and Intensity of UHF Electromagnetic Waves Radiated from Partial Discharge
    Li, Xingwang
    Wu, Siyang
    Ye, Qizheng
    Yang, Chu
    PIERS 2014 GUANGZHOU: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2014, : 1558 - 1561