High robust eddy current tuned tandem mass dampers-inerters for structures under the ground acceleration

被引:11
|
作者
Cao, Liyuan [1 ]
Li, Xueqin [1 ]
Huang, Yu [2 ]
Li, Chunxiang [1 ]
Pan, Hang [1 ]
机构
[1] Shanghai Univ, Sch Mech & Engn Sci, Dept Civil Engn, 333 Nanchen Rd, Shanghai 200444, Peoples R China
[2] Tongji Univ, Coll Civil Engn, Dept Geotech Engn, Shanghai 200092, Peoples R China
关键词
Vibration control; Eddy current tuned tandem mass dampers-inerters; Pattern-search algorithm; Earthquakes; H2 optimal control; VIBRATION CONTROL; OPTIMAL-DESIGN; SYSTEMS; PERFORMANCE;
D O I
10.1016/j.soildyn.2024.109040
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In this work, a novel eddy current tuned tandem mass dampers-inerters, referred to as EC-TTMDI is proposed, a theoretical analysis model of the vibration control mechanism is established, and parameterized analysis and design are conducted using the intelligent optimization algorithm. This model is the single-degree-of-freedom (SDOF) structure with EC-TTMDI subjected to Gaussian white noise base excitation. Specifically, the expression for the displacement variance of the SDOF structure-EC-TTMDI system was firstly obtained with resorting to both the equivalent linearization of eddy current damper (ECD) and residue theorem. The optimization objective function was then defined as minimization of the displacement variance, which is product of the white noise intensity and the square of H2 norm of the model transfer function. Employing the pattern-search algorithm, the variation trends of the objective function and the optimum design parameters were subsequently scrutinized. The vibration damping mechanism of EC-TTMDI is then revealed in terms of control effectiveness, robustness, structural frequency response, suppression bandwidth, and stroke. Finally, the time history response analysis of the SDOF structure-EC-TTMDI system subjected to the near-field impulse, near-field non-impulse, and far-field earthquakes was conducted to further confirm the performance superiority of EC-TTMDI. Results demonstrates that EC-TTMDI offers higher robustness and better control effectiveness compared to TTMDI and TMDI. Furthermore, EC-TTMDI features the damping force limiting characteristic, which enhances the integrity and reliability of TTMDI.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Multiple active-passive tuned mass dampers for structures under the ground acceleration (vol 32, pg 949, 2003)
    Li, CX
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2003, 32 (15): : 2451 - 2451
  • [22] Bidirectional pendulum-type tuned tendem mass dampers-inerters for integrated control of alongwind and crosswind responses in super-tall buildings
    Pan, Hang
    Li, Chunxiang
    Cao, Liyuan
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [23] Performance of dual-layer multiple tuned mass dampers for structures under ground excitations
    Li, Chunxiang
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2006, 6 (04) : 541 - 557
  • [24] Optimum properties of multiple tuned mass dampers for reduction of translational and torsional response of structures subject to ground acceleration
    Li, CX
    Qu, WL
    ENGINEERING STRUCTURES, 2006, 28 (04) : 472 - 494
  • [25] Clutching inerters enhanced tuned mass dampers for structural response mitigation under impulsive and seismic excitations
    Wang, Jingjing
    Zhang, Chao
    Liu, Zhibin
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (02):
  • [26] OPTIMIZATION OF TUNED MASS DAMPERS ATTACHED TO DAMPED STRUCTURES - MINIMIZATION OF MAXIMUM DISPLACEMENT AND ACCELERATION
    Stepanek, Jan
    Maca, Jiri
    NANO & MACRO MECHANICS (NMM 2020), 2021, 30 : 98 - 103
  • [27] Experimental and analytical study on vibration control effects of eddy-current tuned mass dampers under seismic excitations
    Lu, Zheng
    Huang, Biao
    Zhang, Qi
    Lu, Xilin
    JOURNAL OF SOUND AND VIBRATION, 2018, 421 : 153 - 165
  • [28] ROBUST OPTIMUM DESIGN OF TUNED MASS DAMPERS FOR HIGH-RISE BUILDINGS UNDER MODERATE EARTHQUAKES
    Marano, Giuseppe Carlo
    Greco, Rita
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2009, 18 (08): : 823 - 838
  • [29] Optimum tuning of Tuned Mass Dampers for frame structures under earthquake excitation
    Salvi, Jonathan
    Rizzi, Egidio
    STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (04): : 707 - 725
  • [30] Tuned Mass Dampers for Offshore-Structures under Wave-Loading
    Meinhardt, Christian
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 3388 - 3394