Fast Implementation of Iterative Reconstruction with Exact Ray-Driven Projector on GPUs

被引:9
|
作者
Xu F. [1 ]
机构
[1] Siemens Corporate Research, Princeton
关键词
graphics processing units; image reconstruction; tomography;
D O I
10.1016/S1007-0214(10)70005-5
中图分类号
学科分类号
摘要
Iterative methods are popular choices in image reconstruction fields due to their capability of recovering object information from incomplete acquisition data. However, the computation process involves frequent uses of forward and backward projections that are computationally expensive. Past research has proved that a forward projector that can produce high quality images is crucial to achieve a good convergence rate. In this paper a high performance iterative reconstruction framework is introduced, where two most popular iterative algorithms: Simultaneous Algebraic Reconstruction Technique (SART) and Ordered-subsets Expectation Maximization (OSEM) are supported. The framework utilizes Siddon's ray-driven method to generate forward projected images. Benefited from functionalities offered by current generation of graphics processing units (GPUs), it achieves better performance when compared to previous GPU implementations that use grid-interpolated methods, on top of the significant speedups over CPU-based solutions. © 2010 Tsinghua University Press.
引用
收藏
页码:30 / 35
页数:5
相关论文
共 35 条
  • [21] A Fast CPU/GPU Ray Projector for Fully 3D List-Mode PET Reconstruction
    Bert, Julien
    Visvikis, Dimitris
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4126 - 4130
  • [22] Based on Model-driven Fast Iterative Shrinkage Thresholding Network for Bioluminescence Tomography Reconstruction
    Zhang, Heng
    He, Xiaowei
    Guo, Hongbo
    Liu, Yanqiu
    Li, Shuangchen
    Zhao, Yizhe
    He, Xuelei
    Yu, Jingjing
    Hou, Yuqin
    MEDICAL IMAGING 2023, 2023, 12464
  • [23] A Fully GPU-Based Ray-Driven Backprojector via a Ray-Culling Scheme with Voxel-Level Parallelization for Cone-Beam CT Reconstruction
    Park, Hyeong-Gyu
    Shin, Yeong-Gil
    Lee, Ho
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (06) : 709 - 720
  • [24] A ray-driven approach to analytical SPECT reconstruction of non-uniform attenuation with variable focal-length fan-beam collimators
    Wen, JH
    Li, TF
    Liang, ZR
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 731 - 735
  • [25] Forward-Projection Architecture for Fast Iterative Image Reconstruction in X-Ray CT
    Kim, Jung Kuk
    Fessler, Jeffrey A.
    Zhang, Zhengya
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2012, 60 (10) : 5508 - 5518
  • [26] A fast and efficient implementation of an iterative beam hardening correction scheme for X-ray CT
    Fuchs, TO
    Kalender, WA
    RADIOLOGY, 2000, 217 : 405 - 405
  • [27] Fast implementation of the single scatter simulation algorithm and its use in iterative image reconstruction of PET data
    Werling, A
    Bublitz, O
    Doll, J
    Adam, LE
    Brix, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16): : 2947 - 2960
  • [28] Fast implementation of the single scatter simulation algorithm and its use in iterative image reconstruction of PET data
    Werling, A
    Bublitz, O
    Doll, J
    Adam, LE
    Brix, G
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1158 - 1162
  • [29] Fast parallel algorithm for three-dimensional distance-driven model in iterative computed tomography reconstruction
    陈建林
    李磊
    王林元
    蔡爱龙
    席晓琦
    张瀚铭
    李建新
    闫镔
    Chinese Physics B, 2015, 24 (02) : 517 - 524
  • [30] Fast parallel algorithm for three-dimensional distance-driven model in iterative computed tomography reconstruction
    Chen Jian-Lin
    Li Lei
    Wang Lin-Yuan
    Cai Ai-Long
    Xi Xiao-Qi
    Zhang Han-Ming
    Li Jian-Xin
    Yan Bin
    CHINESE PHYSICS B, 2015, 24 (02)