Fast Implementation of Iterative Reconstruction with Exact Ray-Driven Projector on GPUs

被引:9
|
作者
Xu F. [1 ]
机构
[1] Siemens Corporate Research, Princeton
关键词
graphics processing units; image reconstruction; tomography;
D O I
10.1016/S1007-0214(10)70005-5
中图分类号
学科分类号
摘要
Iterative methods are popular choices in image reconstruction fields due to their capability of recovering object information from incomplete acquisition data. However, the computation process involves frequent uses of forward and backward projections that are computationally expensive. Past research has proved that a forward projector that can produce high quality images is crucial to achieve a good convergence rate. In this paper a high performance iterative reconstruction framework is introduced, where two most popular iterative algorithms: Simultaneous Algebraic Reconstruction Technique (SART) and Ordered-subsets Expectation Maximization (OSEM) are supported. The framework utilizes Siddon's ray-driven method to generate forward projected images. Benefited from functionalities offered by current generation of graphics processing units (GPUs), it achieves better performance when compared to previous GPU implementations that use grid-interpolated methods, on top of the significant speedups over CPU-based solutions. © 2010 Tsinghua University Press.
引用
收藏
页码:30 / 35
页数:5
相关论文
共 35 条
  • [1] Fast Implementation of Iterative Reconstruction with Exact Ray-Driven Projector on GPUs
    Fang Xu Siemens Corporate Research
    TsinghuaScienceandTechnology, 2010, 15 (01) : 30 - 35
  • [2] Accuracy and Computing Time of a Ray-Driven Projector/back-Projector for Simulation and Reconstruction in Tomosynthesis and Cone Beam CT Imaging
    Han, T.
    Zhong, Y.
    Chen, L.
    Lai, C.
    Liu, X.
    Shen, Y.
    Ge, S.
    Yi, Y.
    Shaw, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Acceleration of Image Reconstruction with a Ray-Driven Method Using a GPGPU
    Ito, Ryo
    Ogawa, Koichi
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [4] Accurate PET Projector Approximations using Ray-Driven Projectors with Image Domain PSF Modeling
    Qi, Wenyuan
    Yang, Li
    Chan, Chung
    Asma, Evren
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [5] Matrix Implementation of Simultaneous Iterative Reconstruction Technique (SIRT) on GPUs
    Vazquez, Francisco
    Garzon, Ester M.
    Jesus Fernandez, Jose
    COMPUTER JOURNAL, 2011, 54 (11): : 1861 - 1868
  • [6] Fast perspective volume rendering with splatting by utilizing a ray-driven approach
    Mueller, K
    Yagel, R
    VISUALIZATION '96, PROCEEDINGS, 1996, : 65 - +
  • [7] Ray-driven analytical fan-beam SPECT reconstruction with nonuniform attenuation
    Wen, JH
    Li, TF
    Liang, ZR
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 629 - 632
  • [8] An investigation on the property and fast implementation of a ray-driven method for inversion of the attenuated radon transform with variable focusing fan-beam collimators
    Wen, JH
    Wang, ZG
    Li, B
    Liang, ZR
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2138 - 2142
  • [9] Analytical SPECT Reconstruction Algorithm for Helical Cone-beam Geometry Using Ray-driven Technology
    Zhang, Kangping
    Wen, Junhai
    Li, Cuifen
    Yang, Rui
    Dong, Haixiang
    Liang, Zhengrong
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [10] A Comparison Study on Ray-driven Approximation in Re-projection and Back-projection for CT Reconstruction
    Fan, Yi
    Lu, Hongbing
    Ma, Jianhua
    Zhu, Hongbin
    Liu, Yan
    Liang, Zhengrong
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4201 - 4205