Spray dust control measures of tunnel blasting dust based on CFD dust-droplet coupling model and orthogonal test

被引:2
|
作者
Chen, Zheng [1 ]
Zhao, Shulei [1 ]
Dong, Chen [2 ]
Wang, Shuaishuai [3 ]
Guo, Yabin [3 ]
Gao, Xuan [3 ]
Sun, Bing [4 ]
Chen, Wengan [4 ]
Guo, Chun [1 ]
机构
[1] Southwest Jiaotong Univ, Coll Civil Engn, Key Lab Transportat Tunnel Engn, MOE, Chengdu, Peoples R China
[2] Southwest Jiaotong Univ, Sch Transportat & Logist, Chengdu, Peoples R China
[3] CCCC Second Highway Engn Co Ltd, Res & Dev Ctr Construct Technol Long Bridge & Tunn, Xian 710065, Peoples R China
[4] 3 Construct Co, China Railway Engn Grp 10, Hefei 230031, Peoples R China
关键词
Railway tunnel; Blasting dust; Spray; Dust suppression; Coupling model; AIRBORNE DUST; FACE; FLOW; LAW;
D O I
10.1016/j.tust.2024.106233
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In extra-long tunnels, the dust generated by blasting excavation is difficult to discharge through ventilation, which can easily lead to secondary dust generation, severely affecting the health of construction personnel inside the tunnel and potentially increasing the construction interval. To shorten the dust removal time and enhance efficiency during tunnel blasting, this study utilized a single-hole single-track railway tunnel to conduct on-site measurements and numerical simulations of blasting dust. The effectiveness of the dust mist coupling model was validated through indoor model experiments, showing a maximum deviation of 16.94 % between the average concentration at numerical simulation monitoring points and that from model test measurements. Additionally, the model's stability was assessed using three grid sizes: coarse, medium, and fine, with the maximum relative change in dust removal rate reaching 14.75 %. In combination with the original forced ventilation system, a three-section spray dedusting method was designed. The first nozzle was positioned at the center of the forced air duct outlet, with a nozzle diameter of SH2.4 mm. The second section, located 50 m from the tunnel face, contained two nozzles placed at the top and bottom of the section. The third section, situated approximately 100 m from the tunnel face, featured two X-core circular nozzles with a diameter of 2 mm, operating at a spray pressure of 8 MPa. Nine groups of orthogonal experiments were designed using CFD, identifying the spray angle, compressed air duct volume, and spray ring spacing as the most influential factors in dust removal time. Through the addition of Experiment 10 to the orthogonal set and subsequent comparisons, the optimal spray parameters were determined to be a spray angle of 15 degrees, a compressed air duct air volume of 26 m3/s, and a spray ring spacing of 50 m. Based on the analysis of numerical results, it can be concluded that the spray dust reduction measures effectively reduced the dust concentration within 200 m of the tunnel face to a safe level 900 s after blasting.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Optimization of spraying dust reduction technology of continuous miner machine and the dust environment in a tunnel, based on computational fluid dynamics (CFD) technology
    Nie, Wen
    Guo, Cheng
    Zhang, Shaobo
    Peng, Huitian
    Xu, Changwei
    Ma, Qingxin
    Yuan, Mingyue
    Zhou, Weiwei
    Guo, Lidian
    Cheng, Lei
    POWDER TECHNOLOGY, 2022, 398
  • [22] A study on the dust control effect of the dust extraction system in TBM construction tunnels based on CFD computer simulation technology
    Liu, Qiang
    Nie, Wen
    Hua, Yun
    Jia, Lebin
    Li, Chongshan
    Ma, He
    Wei, Cunhou
    Liu, Changqi
    Zhou, Wenjie
    Peng, Huitian
    ADVANCED POWDER TECHNOLOGY, 2019, 30 (10) : 2059 - 2075
  • [23] Deterministic model of open-space dust removal system using water spray nozzle: Effects of polydispersity of water droplet and dust particle
    Charinpanitkul, Tawatchi
    Tanthapanichakoon, Wiwut
    SEPARATION AND PURIFICATION TECHNOLOGY, 2011, 77 (03) : 382 - 388
  • [24] Micro-scale pollution mechanism of dust diffusion in a blasting driving face based on CFD-DEM coupled model
    Haiming Yu
    Weimin Cheng
    Yao Xie
    Huitian Peng
    Environmental Science and Pollution Research, 2018, 25 : 21768 - 21788
  • [25] Micro-scale pollution mechanism of dust diffusion in a blasting driving face based on CFD-DEM coupled model
    Yu, Haiming
    Cheng, Weimin
    Xie, Yao
    Peng, Huitian
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (22) : 21768 - 21788
  • [26] An investigation of the nozzle's atomization dust suppression rules in a fully-mechanized excavation face based on the airflow-droplet-dust three-phase coupling model
    Yu, Haiming
    Cheng, Weimin
    Peng, Huitian
    Xie, Yao
    ADVANCED POWDER TECHNOLOGY, 2018, 29 (04) : 941 - 956
  • [27] The optimization of a dust suppression and clean production scheme in a TBM-constructed tunnel based on an orthogonal experiment
    Liu, Xiaofei
    Nie, Wen
    Zhou, Wenjie
    Liu, Changqi
    Liu, Qiang
    Wei, Cunhou
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 136 (136) : 353 - 370
  • [28] CFD numerical simulation of tunnel dust pollution control using a negative pressure double extraction ventilation system
    Nie, Wen
    Cheng, Chuanxing
    Liu, Qiang
    Guo, Lidian
    Hua, Yun
    Zhang, Haonan
    Zhu, Zilian
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2024, 12 (06):
  • [29] Research on mine cleaner production based on high wettability spray control dust pollution
    Wang, Yapeng
    Jiang, Zhongan
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 25
  • [30] Study on dust control technology and parameters for a coal washing plant screening workshop based on CFD technology of positive-negative pressure dust removal systems
    Liu, Qiang
    Zhu, Zilian
    Hua, Yun
    Guo, Lidian
    POWDER TECHNOLOGY, 2024, 448