The electromagnetic environment of substation threats the safe operation of secondary systems in substation, the electromagnetic compatibility (EMC) immunity test of secondary system in substation with strong electromagnetic environment is very important. According to the experimental and analysis results of electromagnetic environment parameters in substation in literatures, this paper summarized the characteristic values of electromagnetic environment parameters in substation, and proposed the recommended values for the electromagnetic environment parameters of substation, including power frequency electrical and magnetic fields, 1-3 s short-time magnetic field, lightning transient magnetic field, switching transient electric and magnetic fields, lightning interference voltage, switching interference voltage, short-circuit interference voltage, transient and power frequency ground potential rises. By analyzing the general demand to the EMC immunity of secondary system, the requirement to the EMC immunity test of secondary system in substation is proposed. The main characteristic parameters for the EMC immunity test of secondary systems in different locations of substation are also discussed, the test items, which should be added, are also listed, these test items and requirements are more suitable to the actual electromagnetic environments of substations.
引用
收藏
相关论文
共 50 条
  • [21] Behavioral Modeling for Electromagnetic Immunity Analysis for Electronic Systems
    Gao, Xian-Ke
    Chua, Eng-Kee
    Li, Er-Ping
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 862 - 865
  • [22] Safety related systems and electromagnetic compatibility
    Seborsky, Stanislav
    2006 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS, 2006, : 169 - 171
  • [23] Research on Electromagnetic Compatibility Testing Indexes Based on Statistical Process Control
    Wang, Yumei
    Zhang, Kai
    Yan, Li
    2013 5TH IEEE INTERNATIONAL SYMPOSIUM ON MICROWAVE, ANTENNA, PROPAGATION AND EMC TECHNOLOGIES FOR WIRELESS COMMUNICATIONS (MAPE), 2013, : 555 - 558
  • [24] Electromagnetic compatibility in distributed power systems
    Maniak, Krzysztof
    Tomczyk, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (02): : 29 - 33
  • [25] Electromagnetic compatibility in power electronic systems
    Kempski, Adam
    Smolenski, Robert
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (09): : 164 - 171
  • [26] Analysis and Simulation Test on Suppressing Transient Electromagnetic Disturbance of Secondary Cable in Substation with Magnetic Rings
    Xue Y.
    Zhang W.
    Liu Z.
    Ni H.
    Dong Z.
    Yang S.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 5302 - 5312
  • [27] Electromagnetic Compatibility Analysis of the Infocommunication Systems Components on the Flexible Structures Basis
    Zharikova, Irina
    Novoselov, Sergey
    2015 SECOND INTERNATIONAL SCIENTIFIC-PRACTICAL CONFERENCE PROBLEMS OF INFOCOMMUNICATIONS SCIENCE AND TECHNOLOGY (PIC S&T 2015), 2015, : 101 - 103
  • [28] Electromagnetic Compatibility Analysis of Radar and Communication Systems in 35 GHz Band
    Liu, Zebin
    Zou, Weixia
    COMMUNICATIONS, SIGNAL PROCESSING, AND SYSTEMS, CSPS 2018, VOL II: SIGNAL PROCESSING, 2020, 516 : 653 - 660
  • [29] Electromagnetic Compatibility on-site Testing of Secondary Equipment
    Lin, Bai
    Li, Li
    Sun, Zhenhua
    Xu, Qinglin
    Qiu, Yang
    2015 IEEE 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (IEEE EEEIC 2015), 2015, : 461 - 465
  • [30] Analysis of switching transient electromagnetic field in substation
    Lu, TB
    Cui, X
    Yin, HL
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS, 2000, : 31 - 34