Determination of coenzyme Q10 content in raw materials and dietary supplements by high-performance liquid chromatography-UV: Collaborative study

被引:0
|
作者
Lunetta, Steven [1 ]
Roman, Mark [2 ]
Chandrah, A. [2 ]
Edamura, T. [2 ]
Honda, T. [2 ]
LeVanseler, K. [2 ]
Nagarajan, M. [2 ]
Patel, N. [2 ]
Reif, K. [2 ]
Schaneberg, B. [2 ]
Sullivan, D. [2 ]
Trussardo, L. [2 ]
机构
[1] Pharmavite LLC, 1150 Aviation Pl, San Fernando, CA 91340, United States
[2] Tampa Bay Analytical Research, Inc., 10810 72nd St, Largo, FL 33777, United States
来源
Journal of AOAC International | 1600年 / 91卷 / 04期
关键词
An international collaborative study was conducted of a high-performance liquid chromatographic (HPLC)-UV method for the determination of coenzyme Q10 (CoQ10; ubidecarenone) in raw materials and dietary supplements. Ten collaborating laboratories determined the total CoQ10 content in 8 blind duplicate samples. Sample materials included CoQ10 raw material and 4 finished product dietary supplements representing softgels; hardshell gelatin capsules; and chewable wafers. In addition; collaborating laboratories received a negative control and negative control spiked with CoQ10 at low and high levels to determine recovery. Materials were extracted with an acetonitrile - tetrahydrofuran - water mixture. Ferric chloride was added to the test solutions to ensure all CoQ10 was in the oxidized form. The HPLC analyses were performed on a C18 column using UV detection at 275 nm. Repeatability relative standard deviations (RSDr) ranged from 0.94 to 5.05%. Reproducibility relative standard deviations (RSDR) ranged from 3.08 to 17.1%; with HorRat values ranging from 1.26 to 5.17. Recoveries ranged from 74.0 to 115%. Based on these results; the method is recommended for Official First Action for determination of CoQ10 in raw materials and dietary supplement finished products containing CoQ10 at a concentration of >100 mg CoQ10/g test material;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:702 / 708
相关论文
共 50 条
  • [31] Determination of total soy isoflavones in dietary supplements, supplement ingredients, and soy foods by high-performance liquid chromatography with ultraviolet detection: Collaborative study
    Collison, Mark W.
    JOURNAL OF AOAC INTERNATIONAL, 2008, 91 (03) : 489 - 500
  • [32] Determination of total soy isoflavones in dietary supplements, supplement ingredients, and soy foods by high-performance liquid chromatography with ultraviolet detection: Collaborative study
    Collison, Mark W.
    Delmonte, P.
    Devore, R.
    Fu, B.
    Hall, A.
    Hughes, B.
    Kohn, A.
    Lawson, L.
    LeBouquin, R.
    Mateja, B.
    Morice, G.
    Platteschor, P.
    Popov-Rihter, V.
    Reif, K.
    Sanchez, R.
    Shang, Y.
    Sun, C.
    Swope, J.
    Thakker, K.
    Tremblay, L.
    Wijewickreme, A.N.
    Young, K.
    Zhao, M.
    Zhou, F.
    Journal of AOAC International, 1600, 91 (03): : 489 - 500
  • [33] Derivatization, characterization and high-performance liquid chromatography-UV detection method for benomyl determination in wettable powder (benlate)
    Özer, M
    Aydin, A
    Özer, L
    FRESENIUS ENVIRONMENTAL BULLETIN, 2006, 15 (04): : 322 - 327
  • [34] Development of a Rapid Determination of Pesticides in Coated Seeds Using a High-Performance Liquid Chromatography-UV Detection System
    Bourgin, Marc
    Bize, Magali
    Durand, Sebastien
    Albet, Joel
    Violleau, Frederic
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (21) : 10032 - 10037
  • [35] Development of a new high performance liquid chromatography method for measurement of coenzyme Q10 in healthy blood plasma
    Abdul-Rasheed, Omar E.
    Farid, Yahya Y.
    SAUDI MEDICAL JOURNAL, 2009, 30 (09) : 1138 - 1143
  • [36] Quantitative determination of coenzyme Q10 from dietary supplements by FT-NIR spectroscopy and statistical analysis
    Racz, Anita
    Vass, Andrea
    Heberger, Karoly
    Fodor, Marietta
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (10) : 2887 - 2898
  • [37] Quantitative determination of coenzyme Q10 from dietary supplements by FT-NIR spectroscopy and statistical analysis
    Anita Rácz
    Andrea Vass
    Károly Héberger
    Marietta Fodor
    Analytical and Bioanalytical Chemistry, 2015, 407 : 2887 - 2898
  • [38] Use of high-performance liquid chromatography-UV and gas chromatography-mass spectrometry for determination of the imidacloprid content of honeybees, pollen, paper filters, grass, and flowers
    Rossi, S
    Sabatini, AG
    Cenciarini, R
    Ghini, S
    Girotti, S
    CHROMATOGRAPHIA, 2005, 61 (3-4) : 189 - 195
  • [39] Microcolumn high-performance liquid chromatography with UV detection for the determination of anions in environmental materials
    Baram, GI
    Vereshchagin, AL
    Golobokova, LP
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (09) : 854 - 857
  • [40] Validated high performance liquid chromatography-UV detection method for the determination of daptomycin in human plasma
    Martens-Lobenhoffer, Jens
    Kielstein, Jan T.
    Oye, Catrin
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 546 - 550