Transient vibration control on coupled unit-plant structure of pumped storage power station based on MRD optimal layout

被引:0
|
作者
Zhang, Jinjian [1 ,2 ]
Ma, Zhenyue [1 ,2 ]
Xu, Wenjie [1 ]
Wang, Xueni [3 ,4 ]
Zhang, Kaiwen [3 ]
Zhang, Leike [3 ]
机构
[1] School of Hydraulic Engineering, Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian,116023, China
[2] State Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University, Tianjin,300354, China
[3] College of Water Resources Science and Engineering, Taiyuan University of Technology, Taiyuan,030024, China
[4] Henan Key Laboratory of Water Resources Conservation and Intensive Utilization in the Yellow River Basin, Zhengzhou,450046, China
基金
中国国家自然科学基金;
关键词
Electromagnetic transients - Structural optimization;
D O I
10.1016/j.ymssp.2024.112111
中图分类号
学科分类号
摘要
To address the recurring vibration in the integrated unit-plant structure system during the transitional phases of pumped storage power station (PSPS), the magnetorheological damper (MRD) is introduced in this paper to investigate transient vibration control within the coupled unit-plant structure (CUPS). Firstly, taking an actual PSPS as a case study, a unit regulation system model is developed based on one-dimensional transient flow theory, the method of characteristics (MOC), and the improved Suter transformation. Secondly, integrating the position function of unit shaft system, a nonlinear dynamic model of MRD is constructed, and the MRD damping force accounting for axial position parameters is derived. Additionally, on the basis of Lagrange method and finite element method, a mathematical model of unit shaft system and a finite element model for plant structure under the coupling effects of multiple vibration sources are established. Finally, the response to a sudden 10% load increase in generator condition of pumped storage unit is calculated through numerical simulation, and the effects of different damper position functions on the vibration characteristics of rotor and runner are analyzed to identify the optimal installation position for effective vibration control. The research results indicate that, optimizing the damper layout position enables the MRD to effectively reduce the vibration amplitude of rotor and runner, enhancing spectral characteristics. Furthermore, optimizing MRD positions significantly improves the vibration performance of plant structure. After the optimization of MRD positions, the vibration attenuation rate of plant structure accelerates, leading to a quicker stabilization, particularly noticeable in the generator floor. The findings of this study offer valuable engineering guidance for managing transient vibration in the integrated unit-plant system of PSPS. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 39 条
  • [31] Study of coordinated control method based on Generator Units share High-Voltage Variable Frequency Starting of the Pumped Storage Power Station
    Mu Xianyong
    Yin Jiayue
    Wang Kunjie
    He Li
    He Le
    Li Xiaoming
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON CIVIL, ARCHITECTURAL AND HYDRAULIC ENGINEERING (ICCAHE 2016), 2016, 95 : 214 - 218
  • [32] Control Strategy for Variable Speed Pumped Storage Power Station based on Double-fed Induction Generator under Different Grid Conditions
    Jiang, Xinjian
    He, Ruifei
    Peng, Peng
    Sun, Xudong
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 3912 - 3917
  • [33] Research on control strategy of full-size converter-based variable speed pumped storage unit in power generation condition
    Zhao, Guopeng
    Zhang, Yongxin
    Li, Zheng
    Ren, Jiyun
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (11):
  • [34] Development of an Optimal Control Strategy for Temperature Regulation and Thermal Storage Operation of a Solar Power Plant Based on Fresnel Collectors
    Biazetto, Paulo H. F.
    de Andrade, Gustavo A.
    Normey-Rico, Julio E.
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2023, 31 (03) : 1149 - 1164
  • [35] Optimal frequency response coordinated control strategy for hybrid wind-storage power plant based on state reconstruction
    Tian, Xinshou
    Chi, Yongning
    Cheng, Peng
    Zhao, Yihui
    Liu, Hongzhi
    IET RENEWABLE POWER GENERATION, 2024, : 2892 - 2906
  • [36] Optimal design methods for a digital human-computer interface based on human reliability in a nuclear power plant part 1: Optimization method for monitoring unit layout
    Jiang, Jianjun
    Zhang, Li
    Wang, Yiqun
    Dai, Licao
    Peng, Yuyuan
    Li, Pengcheng
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2015, 49 : 90 - 96
  • [37] Modeling and simulation to optimize direct power control of DFIG in variable-speed pumped-storage power plant using teaching-learning-based optimization technique
    Hosseini, Seyed Mohammad Hassan
    Rezvani, Alireza
    SOFT COMPUTING, 2020, 24 (22) : 16895 - 16915
  • [38] Modeling and simulation to optimize direct power control of DFIG in variable-speed pumped-storage power plant using teaching–learning-based optimization technique
    Seyed Mohammad Hassan Hosseini
    Alireza Rezvani
    Soft Computing, 2020, 24 : 16895 - 16915
  • [39] Optimal control strategy of wind-energy storage hydrogen production power plant based on efficiency characteristics of hydrogen production device
    Sun D.
    Yu J.
    Ruan J.
    Zheng W.
    Zu G.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2023, 43 (12): : 53 - 61